A hybrid force-magnetic control scheme for flexible medical device steering

被引:4
作者
Huang, Yuanrui [1 ,2 ]
Ma, Runyu [3 ]
Liu, Hongbin [1 ,2 ,4 ,5 ]
机构
[1] Univ Chinese Acad Sci, Sch Artificial Intelligence, Beijing 100049, Peoples R China
[2] Chinese Acad Sci, Inst Automat, Beijing 100190, Peoples R China
[3] Beihang Univ, Sch Gen Engn, Beijing, Peoples R China
[4] Chinese Acad Sci, Ctr AI & Robot CAIR, Hong Kong Inst Sci & Innovat, Hong Kong 100045, Peoples R China
[5] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
关键词
Soft robotics; Magnetic actuation; Steerable catheters/needles; Force control; CATHETER; GUIDEWIRE; SYSTEM; ARRAY;
D O I
10.1016/j.mechatronics.2023.103072
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Magnetically-actuated flexible surgical robot has promising applications for ultra-narrow and tortuous orifices, however, how to minimize the energy consumption, physical interaction between the external electromagnet (EEM) and the human body, and the bulky size of the magnetic actuation system remains a major challenge. This work presents a hybrid force-magnetic control scheme that can magnetically steer catheters with the least distance in order to reduce energy consumption and the size of the magnet. In addition, the use of force feedback control allows the motion of magnet adapts to the movement of patient's body, ensuring safety during the operation. The scheme is composed of two parts: a Jacobian-based inverse kinematic model that enables 3D position control of the catheter's distal tip through the EEM, and a force control algorithm based on admittance control that converts external forces applied to the magnet into position errors, making the system compliant that allows for safe contact with the human body. Experiment was conducted to validate the feasibility and accuracy of the proposed control scheme. The results show that the catheter's distal tip can be controlled to follow desired trajectories with a minimum Root Mean Square (RMS) error of 0.43 +/- 0.22 mm, and the hybrid control scheme can reduce electrical power consumption effectively while achieving similar performance with an RMS error of 0.52 +/- 0.41 mm. It is also able to maintain contact forces within a safe range (<15 N) during actuation.
引用
收藏
页数:10
相关论文
共 36 条
[1]   Continuum Robots for Medical Applications: A Survey [J].
Burgner-Kahrs, Jessica ;
Rucker, D. Caleb ;
Choset, Howie .
IEEE TRANSACTIONS ON ROBOTICS, 2015, 31 (06) :1261-1280
[2]  
Chen G, 2006, 2006 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-12, P168
[3]   Challenges of continuum robots in clinical context: a review [J].
da Veiga, Tomas ;
Chandler, James H. ;
Lloyd, Peter ;
Pittiglio, Giovanni ;
Wilkinson, Nathan J. ;
Hoshiar, Ali K. ;
Harris, Russell A. ;
Valdastri, Pietro .
PROGRESS IN BIOMEDICAL ENGINEERING, 2020, 2 (03)
[4]  
Edelmann J, 2017, Magnetic control of continuum devices, V36, P68, DOI [10.1177/0278364916683443, DOI 10.1177/0278364916683443]
[5]   Force and Position Control System for Freehand Ultrasound [J].
Gilbertson, Matthew W. ;
Anthony, Brian W. .
IEEE TRANSACTIONS ON ROBOTICS, 2015, 31 (04) :835-849
[6]   Model Predictive Interaction Control for Robotic Manipulation Tasks [J].
Gold, Tobias ;
Voelz, Andreas ;
Graichen, Knut .
IEEE TRANSACTIONS ON ROBOTICS, 2023, 39 (01) :76-89
[7]  
Graetzel CF, 2019, IEEE INT CONF ROBOT, P3895, DOI [10.1109/ICRA.2019.8793704, 10.1109/icra.2019.8793704]
[8]  
Greigarn T, 2015, IEEE INT CONF ROBOT, P2236, DOI 10.1109/ICRA.2015.7139495
[9]   Control of intravascular catheters using an array of active steering coils [J].
Gudino, N. ;
Heilman, J. A. ;
Derakhshan, J. J. ;
Sunshine, J. L. ;
Duerk, J. L. ;
Griswold, M. A. .
MEDICAL PHYSICS, 2011, 38 (07) :4215-4224
[10]   The ARMM System-Autonomous Steering of Magnetically-Actuated Catheters: Towards Endovascular Applications [J].
Heunis, Christoff M. ;
Wotte, Yannik P. ;
Sikorski, Jakub ;
Furtado, Guilherme Phillips ;
Misra, Sarthak .
IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (02) :705-712