Effect of Sacropelvic Hardware on Axis and Center of Rotation of the Sacroiliac Joint: A Finite Element Study

被引:0
|
作者
Panico, Matteo [1 ,2 ]
Chande, Ruchi D. [3 ]
Polly, David W. [4 ]
Lindsey, Derek P. [3 ]
Villa, Tomaso M. T. [1 ,2 ]
Yerby, Scott A. [3 ]
Brayda-Bruno, Marco [1 ]
Galbusera, Fabio [5 ,6 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, Milan, Italy
[2] Politecn Milan, Dept Chem Mat & Chem Engn Giulio Natta, Milan, Italy
[3] SI BONE Inc, Santa Clara, CA USA
[4] Univ Minnesota, Dept Orthopaed Surg, Minneapolis, MN USA
[5] Schulthess Clin, Spine Ctr, Zurich, Switzerland
[6] Schulthess Clin, Lengghalde 2, CH-8008 Zurich, Switzerland
关键词
sacropelvic fixation; triangular implants; S2 alar-iliac screws; ADULT SPINAL DEFORMITY; FIXATION; FUSION; PAIN; ANATOMY; LUMBAR; INSTRUMENTATION; COMPLICATIONS; MOVEMENTS; DIAGNOSIS;
D O I
10.14444/8387
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The sacroiliac joint (SIJ) transfers the load of the upper body to the lower extremities while allowing a variable physiological movement among individuals. The axis of rotation (AoR) and center of rotation (CoR) of the SIJ can be evaluated to analyze the stability of the SIJ, including when the sacrum is fixed. The purpose of this study was to determine how load intensity affects the SIJ for the intact model and to characterize how sacropelvic fixation performed with different techniques affects this joint.Methods: Five T10-pelvis models were used: (1) intact model; (2) pedicle screws and rods in T10 -S1; (3)pedicle screws and rods in T10 -S1, and bilateral S2 alar- iliac screws (S2AI); (4) pedicle screws and rods in T10 -S1, bilateral S2AI screws, and triangular implants inserted bilaterally in a sacral alar- iliac trajectory ; and (5) pedicle screws and rods in T10 -S1, bilateral S2AI screws, and 2 bilateral triangular implants inserted in a lateral trajectory. Outputs of these models under flexion-extension were compared: AoR and CoR of the SIJ at incremental steps from 0 to 7.5 Nm for the intact model and AoR and CoR of the SIJ for the instrumented models at 7.5 Nm.Results: The intact model was validated against an in vivo study by comparing range of motion and displacement of the sacrum. Increasing the load intensity for the intact model led to an increase of the rotation of the sacrum but did not change the CoR. Comparison among the instrumented models showed that sacropelvic fixation techniques reduced the rotation of the sacrum and stabilized the SIJ, in particular with triangular implants.Conclusion: The study outcomes suggest that increasing load intensity increases the rotation of the sacrum but does not influence the CoR, and use of sacropelvic fixation increases the stability of the SIJ, especially when triangular implants are employed.Clinical Relevance: The choice of the instrumentation strategy for sacropelvic fixation affects the stability of the construct in terms of both range of motion and axes of rotation, with direct consequences on the risk of failure and mobilization. Clinical studies should be performed to confirm these biomechanical findings.
引用
收藏
页码:122 / 131
页数:11
相关论文
共 50 条
  • [21] Phase-specific changes in hip joint loading during gait following sacroiliac joint fusion: Findings from a finite element analysis
    Kumaran, Yogesh
    Bonsu, Janice M.
    Tripathi, Sudharshan
    Soehnlen, Sophia M.
    Quatman, Carmen E.
    CLINICAL BIOMECHANICS, 2025, 122
  • [22] Three-Dimensional Finite Element Analysis of the Effects of Ligaments on Human Sacroiliac Joint and Pelvis in Two Different Positions
    Yang, Jiajing
    Zhao, Gaiping
    Xu, Haifei
    Wang, Fei
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (08):
  • [23] Effect of revision sacroiliac joint fusion on unresolved pain and disability: a retrospective cohort study
    Brown, Levi
    Swiontkowski, Marc
    Odland, Kari
    Polly Jr, David W.
    Haselhuhn, Jason
    EUROPEAN SPINE JOURNAL, 2024, 33 (02) : 533 - 542
  • [24] Effect of revision sacroiliac joint fusion on unresolved pain and disability: a retrospective cohort study
    Levi Brown
    Marc Swiontkowski
    Kari Odland
    David W. Polly
    Jason Haselhuhn
    European Spine Journal, 2024, 33 : 533 - 542
  • [25] Biomechanical study of tarsometatarsal joint fusion using finite element analysis
    Wang, Yan
    Li, Zengyong
    Zhang, Ming
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (11) : 1394 - 1400
  • [26] Vibration Energy Color Doppler Imaging (VECDI) in Evaluating the Effect of Screw Fixation on Sacroiliac Joint Stiffness: A Prospective Pilot Study
    Gottlich, Caleb
    Githens, Thomas
    Drusch, Alex
    Jain, Neil
    Caroom, Cyrus
    Sizer, Phillip S.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [27] Sequential damage assessment of the posterolateral complex of the knee joint: a finite element study
    Wu, Cong-Cong
    Ye, Li-Mei
    Li, Xiao-Fei
    Shi, Lin-Jun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [28] Biomechanical effects of joint disc perforation on the temporomandibular joint: a 3D finite element study
    Gao, Wentong
    Lu, Jie
    Gao, Xiang
    Zhou, Jianping
    Dai, Hongwei
    Sun, Min
    Xu, Jie
    BMC ORAL HEALTH, 2023, 23 (01)
  • [29] Evaluation of iliac screw, S2 alar-iliac screw and laterally placed triangular titanium implants for sacropelvic fixation in combination with posterior lumbar instrumentation: a finite element study
    Gloria Casaroli
    Fabio Galbusera
    Ruchi Chande
    Derek Lindsey
    Ali Mesiwala
    Scott Yerby
    Marco Brayda-Bruno
    European Spine Journal, 2019, 28 : 1724 - 1732
  • [30] The Effect of Apical Vertebra Position on Growing Rod Treatment: A Clinical and Finite Element Study
    Dursun, Gokay
    Cetik, Riza M.
    Guzel, Dilek
    Demirkiran, Halil Gokhan
    Ramazanov, Rafik
    Dede, Ozgur
    Gurses, Ercan
    Yazici, Muharrem
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2022, 42 (06) : E552 - E558