Reliability of maximal respiratory nasal pressure tests in healthy young adults

被引:1
|
作者
de Lima, Jackson C. C. [1 ,2 ,3 ]
Resqueti, Vanessa R. [1 ,2 ,3 ]
Marcelino, Ana Aline [1 ,2 ,3 ]
da Fonseca, Jessica Danielle M. [1 ,2 ,3 ]
Paz, Ana Lista [4 ]
Dias, Fernando A. Lavezzo [5 ]
Otto-Yanez, Matias [6 ]
Fregonezi, Guilherme A. F. [1 ,2 ,3 ]
机构
[1] Univ Fed Rio Grande do Norte, Hosp Univ Onofre Lopes, Empresa Brasileira Serv Hospitalares EBSERH & Dept, PneumoCardioVasc Lab HUOL, Natal, RN, Brazil
[2] Univ Fed Rio Grande do Norte, Dept Fisioterapia, Natal, RN, Brazil
[3] Univ Fed Rio Grande do Norte, Dept Fisioterapia, Lab Inovacao Tecnol Reabilitacao, Natal, RN, Brazil
[4] Univ A Coruna, Fac Fisioterapia, La Coruna, Spain
[5] Univ Fed Parana, Dept Fisiol, Curitiba, PR, Brazil
[6] Univ Autonoma Chile, Kinesiol, Santiago, Chile
来源
PLOS ONE | 2023年 / 18卷 / 11期
关键词
INSPIRATORY PRESSURE; REFERENCE VALUES; MUSCLE STRENGTH; MOUTH; REPRODUCIBILITY;
D O I
10.1371/journal.pone.0287188
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
IntroductionSniff nasal inspiratory (SNIP) and expiratory pressure (SNEP) may complement the assessment of respiratory muscle strength. Thus, specifying their reliability is relevant to improving the clinical consistency of both tests.ObjectiveTo assess the reliability of SNIP and SNEP in healthy young adults.MethodsThis cross-sectional study included self-reported healthy aged 18 to 29 years. SNIP was performed using a plug to occlude one nostril, while SNEP was conducted using a facemask. Participants performed 20 SNIP and SNEP maneuvers with 30-second intervals in between. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimum detectable change (MDC) assessed the reliability of SNIP and SNEP. Analyses were conducted between the highest peak pressure and the first reproducible maneuver in men and women.ResultsThe total sample comprised 32 participants: 16 men and 16 women. The ICC, SEM, and MDC for SNIP maneuvers were 0.994 (95%CI 0.988 to 0.997), 1.820 cmH2O, and 5.043 cmH2O, respectively. For SNEP, these parameters were 0.950 (95%CI 0.897 to 0.976), 6.03 cmH2O, and 16.716 cmH2O. The SNIP and SNEP in men showed ICC of 0.992 (95%CI 0.977 to 0.997) and 0.877 (95%CI 0.648 to 0.957), SEM of 2.07 and 7.66 cmH2O, and MDC of 5.74 and 21.23 cmH2O. In women, SNIP and SNEP presented ICC of 0.992 (95%CI 0.977 to 0.997) and 0.957 (95%CI 0.878 to 0.985), SEM of 1.15 and 6.11 cmH2O, and MDC of 3.19 and 16.95 cmH2O. Also, 60% of the highest SNIPs occurred among the 11th and 20th maneuvers in men and women. In men, 55% of the highest SNEPs occurred among the 11th and 20th maneuvers; this value was 50% in women.ConclusionSNIP and SNEP showed excellent reliability. The reliability of SNIP and SNEP in men was good and excellent, respectively, whereas both tests had excellent reliability in women. Also, women reached the highest peak pressure faster than men in both tests.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Short-term heart rate variability in healthy young adults The Cardiovascular Risk in Young Finns Study
    Koskinen, Tuomas
    Kahonen, Mika
    Jula, Antti
    Laitinen, Tomi
    Jarvinen, Liisa Keltikangas
    Viikari, Jorma
    Valimaki, Ilkka
    Raitakari, Olli T.
    AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2009, 145 (1-2): : 81 - 88
  • [32] Nasal Nitric Oxide in Healthy Adults - Reference Values and Affecting Factors
    Antosova, M.
    Mokra, D.
    Tonhajzerova, I.
    Mikolka, P.
    Kosutova, P.
    Mestanik, M.
    Pepucha, L.
    Plevkova, J.
    Buday, T.
    Calkovsky, V.
    Bencova, A.
    PHYSIOLOGICAL RESEARCH, 2017, 66 : S247 - S255
  • [33] Reference equations for the performance of healthy adults on field walking tests
    Dourado, Victor Zuniga
    Vidotto, Milena Carlos
    Fernandes Guerra, Ricardo Luis
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2011, 37 (05) : 607 - 614
  • [34] Evaluating the Reliability of Transcranial Doppler Ultrasonography in Healthy Normal Adults
    Sharma, Jyoti
    Harris, Rachel
    Blatt, Melissa
    Zielonka, Tania
    Kuo, Yen-Hong
    Martinez, Maria Alice Manalac
    Menda, Babita
    Canfora, Paula
    DiBenedetto, Rose
    Cohn, Stephen M.
    AMERICAN SURGEON, 2023, 89 (11) : 4902 - 4904
  • [35] Analysis of tongue pressure in Brazilian young adults
    Prandini, Estefania Leite
    Totta, Tatiane
    Salles Bueno, Mariana da Rocha
    Rosa, Raquel Rodrigues
    Giglio, Lucia Dantas
    Trawitzki, Luciana VitalianoVoi
    Berretin-Felix, Giedre
    de Felicio, Claudia Maria
    Genaro, Katia Flores
    CODAS, 2015, 27 (05): : 478 - 482
  • [36] The reliability and intensity dependence of maximum mouth pressure during bench press exercise in healthy athletes
    Blazek, Dusan
    Pisz, Anna
    Pecha, Ondrej
    Kubovy, Petr
    BALTIC JOURNAL OF HEALTH AND PHYSICAL ACTIVITY, 2020, 12 (01) : 1 - 10
  • [37] Repeatability of standardised nasal nitric oxide measurements in healthy and asthmatic adults and children
    Kharitonov, SA
    Walker, L
    Barnes, PJ
    RESPIRATORY MEDICINE, 2005, 99 (09) : 1105 - 1114
  • [38] Six-minute walk distance in healthy young adults
    Halliday, Stephen J.
    Wang, Li
    Yu, Chang
    Vickers, Brian P.
    Newman, John H.
    Fremont, Richard D.
    Huerta, Luis E.
    Brittain, Evan L.
    Hemnes, Anna R.
    RESPIRATORY MEDICINE, 2020, 165
  • [39] Reliability of the hyperaemic response to passive leg movement in young, healthy women
    Lew, Lindsay A.
    Liu, Kaitlyn R.
    Pyke, Kyra E.
    EXPERIMENTAL PHYSIOLOGY, 2021, 106 (09) : 2013 - 2023
  • [40] Reference values of respiratory impedance with impulse oscillometry in healthy Chinese adults
    Liang, Xiao-Lin
    Gao, Yi
    Guan, Wei-Jie
    Du, Jing
    Chen, Li
    Han, Wen
    Liu, Jin-Ming
    Lu, Yong
    Peng, Yi
    Zhao, Bing-Rong
    Wang, Tao
    Zheng, Jin-Ping
    JOURNAL OF THORACIC DISEASE, 2021, 13 (06) : 3680 - +