Advances in the extraction methods for the environmental analysis of non-steroidal anti-inflammatory drugs (NSAIDs)

被引:7
|
作者
Rodriguez-Saldana, Veronica [1 ]
Castro-Garcia, Cesar [1 ]
Rodriguez-Maese, Rogelio [1 ]
Leal-Quezada, Luz O. [1 ]
机构
[1] Adv Mat Res Ctr CIMAV SC, Environm & Energy Dept, Miguel Cervantes 120, Chihuahua 31136, Mexico
关键词
Non-steroidal anti-inflammatory drugs (NSAIDs); Extraction techniques; Water samples; Analytical performance; Validation parameters; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; BAR SORPTIVE EXTRACTION; METAL-ORGANIC FRAMEWORK; MICROWAVE-ASSISTED EXTRACTION; WATER SAMPLES; IONIC LIQUIDS; ACIDIC DRUGS; MICROEXTRACTION; PHARMACEUTICALS;
D O I
10.1016/j.trac.2023.117409
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring of non-steroidal anti-inflammatory drugs (NSAIDs) in environmental samples is an important step in understanding the widespread of these emerging pollutants in different environmental compartments, mainly water, and encouraging their regulation. The extraction process is critical in order to isolate these analytes from complex water matrices, improving their preconcentration, and accurate quantification. Several extraction methods have been developed and validated in the past decade and many of them have been successfully applied in the analysis of NSAIDs in water samples. This review performs a discussion of the advances of these extraction methods with emphasis on their validation parameters and analytical performance. We retrieved studies in which different extraction methods were developed for the determination of NSAIDs in water samples from two different databases using several keywords after an inclusion-exclusion process. The characteristics of the extraction methods, including the development process, NSAIDs determined, coupled analytical technique, and limits of detection, as well as other performance parameters, were assessed. Additionally, the advantages and limitations of each method such as extraction time, analytical performance, reusability, and range of application, were also discussed.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Non-Steroidal Anti-Inflammatory Drugs: Identifying the Risk Factors in the Patients
    Qazi, Nasreen
    Mashori, Ghulam Rasool
    Shah, Shaheen
    Abbas, Afshan
    Maheshwari, Mohan Perkash
    Dahri, Ghulam Mustafa
    JOURNAL OF THE LIAQUAT UNIVERSITY OF MEDICAL AND HEALTH SCIENCES, 2009, 8 (02): : 177 - 180
  • [42] Simultaneous determination of non-steroidal anti-inflammatory drugs and oestrogenic hormones in environmental solid samples
    Kumirska, Jolanta
    Migowska, Natalia
    Caban, Magda
    Lukaszewicz, Paulina
    Stepnowski, Piotr
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 508 : 498 - 505
  • [43] Selected aspects of safety profile of non-steroidal anti-inflammatory drugs
    Rell, Krzysztof
    PEDIATRIA I MEDYCYNA RODZINNA-PAEDIATRICS AND FAMILY MEDICINE, 2011, 7 (01): : 41 - 48
  • [44] Recent advances of nanomaterials for non-steroidal anti-inflammatory drugs removal from wastewater: a critical review
    Mangalam, Jimmy
    Sharma, Jyoti
    Sharma, Mahima
    Mishra, Yogendra Kumar
    Nigam, Subhasha
    Joshi, Monika
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2024, 26 (06) : 1705 - 1729
  • [45] Efficient determination of non-steroidal anti-inflammatory drugs by micellar electrokinetic chromatography in wastewater
    Alatawi, Hanan
    Hogan, Anna
    Albalawi, Ibtihaj
    Alsefri, Samia
    Moore, Eric
    ANALYTICAL METHODS, 2023, 15 (11) : 1402 - 1409
  • [46] Occurrence and toxicological assessment of six non-steroidal - steroidal anti-inflammatory - inflammatory drugs (NSAIDs) in a wastewater treatment plant in Słupsk ł upsk (Poland)
    Stec, Marcin
    Astel, Aleksander
    ECOHYDROLOGY & HYDROBIOLOGY, 2024, 24 (03) : 523 - 534
  • [47] Magnetite nanoparticles coated with covalently immobilized ionic liquids as a sorbent for extraction of non-steroidal anti-inflammatory drugs from biological fluids
    Amiri, Maryam
    YadollahYamini
    Safari, Meysam
    Asiabi, Hamid
    MICROCHIMICA ACTA, 2016, 183 (07) : 2297 - 2305
  • [48] Counter-flow electrokinetic supercharging for the determination of non-steroidal anti-inflammatory drugs in water samples
    Dawod, Mohamed
    Breadmore, Michael C.
    Gujit, Rosanne M.
    Haddad, Paul R.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 3380 - 3386
  • [49] Fabrication and characterization of metal organic frameworks/polyvinyl alcohol cryogel and their application in extraction of non-steroidal anti-inflammatory drugs in water samples
    Wang, Yudan
    Zhang, Yang
    Cui, Jianan
    Li, Shuo
    Yuan, Ming
    Wang, Ting
    Hu, Qi
    Hou, Xiaohong
    ANALYTICA CHIMICA ACTA, 2018, 1022 : 45 - 52
  • [50] tNOX, an alternative target to COX-2 to explain the anticancer activities of non-steroidal anti-inflammatory drugs (NSAIDS)
    Morré, DJ
    Morre, DM
    MOLECULAR AND CELLULAR BIOCHEMISTRY, 2006, 283 (1-2) : 159 - 167