Narrow inferior-central septum-based pedicle: A safe technique to improve aesthetic outcomes in breast reduction

被引:3
|
作者
Longo, Benedetto [1 ,6 ]
D'Orsi, Gennaro [2 ]
La Padula, Simone [3 ]
Atzeni, Matteo [4 ]
Vanni, Gianluca [5 ]
Buonomo, Claudio Oreste [5 ]
Cervelli, Valerio [1 ]
机构
[1] Tor Vergata Univ Rome, Chair Plast Surg, Sch Med & Surg, Dept Surg Sci, Rome, Italy
[2] Tor Vergata Univ Rome, Sch Med & Surg, Dept Surg Sci, PhD Program Med Surg Appl Sci, Rome, Italy
[3] Univ Napoli Federico II, Dept Plast & Reconstruct Surg, Via Pansini 5, I-80131 Naples, Italy
[4] Univ Cagliari, Univ Hosp Duilio Casula, Fac Med & Surg, Dept Surg Sci,Plast Surg & Microsurg Unit, Cagliari, Italy
[5] Tor Vergata Univ Rome, Sch Med & Surg, Dept Surg Sci, Div Breast Unit, Rome, Italy
[6] Tor Vergata Univ Rome, Chair Plast Surg, Sch Med & Surg, Dept Surg Sci, Via Montpellier 1, I-00133 Rome, Italy
关键词
Breast reduction; Wuringer septum; Narrow inferior-central pedicle; Septum-based pedicle; Outcome; Bottoming-out; MAMMAPLASTY; LONG; SENSATION; SUPERIOR;
D O I
10.1016/j.bjps.2023.07.016
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Inferior-central pedicle has some aesthetic drawbacks, including hypertrophic scar along the inframammary fold (IMF), squaring of the breast contours, and propensity to develop long-term 'bottoming-out.' This study aimed to verify if the narrow inferiorcentral (NIC) septum-based pedicle can allow the surgeon to improve aesthetic outcomes compared with the traditional inferior-central pedicle approach. Methods: Forty breasts underwent NIC-based breast reduction (group A), and 37 underwent traditional inferior-central pedicles (group B). The NIC pedicle was drawn with a width of 3.5-4.5 cm. The recorded measurements were sternal notch to nipple distance (S-N) and nipple to IMF distance (N-IMF) at the time of preoperative markings and follow-up 1, 6, and 18 months after the procedure. Results: The two groups were homogeneous regarding demographics, operative data, and preoperative S-N and N-IMF distances. Both groups showed no total or partial nipple-areola necrosis. At the 18-month follow-up, S-N (p < 0.00001) and N-IMF (p = 0.00039) distances were statistically different between the two groups, in favour of NIC group A. Changes in N-IMF distances between the 1- and 18-month visits were statistically different among groups (p < 0.0001), with a length variation of + 17.51% and + 28.46%, respectively. Patient satisfaction rate regarding "breast shape" (p = 0.021), "lower pole appearance" (p = 0.00017), and "scar" (p = 0.047) were higher in group A. Conclusion: NIC-based pedicle proved to be a safe procedure and allowed us to overcome limitations that typically characterise the inferior pedicle, i.e., 'bottoming-out' deformity, hypertrophic scar of the lower pole, and squaring of the breast contours. Level of evidence: II. (c) 2023 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:226 / 234
页数:9
相关论文
共 16 条
  • [1] Modified Wise Pattern Inferior-central Pedicle Breast Reduction: Technical Pearls for Reliable Aesthetic Outcomes
    Ramly, Elie P.
    Colwell, Amy S.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2025, 13 (01)
  • [2] The Central Pillar Technique: A New Septum-Based Pedicle Design for Reduction Mammaplasty
    Bayramicli, Mehmet
    AESTHETIC SURGERY JOURNAL, 2012, 32 (05) : 578 - 590
  • [4] Septum-Based Mammaplasty: A Surgical Technique Based on Wuringer's Septum for Breast Reduction
    Hamdi, Moustapha
    Van Landuyt, Koenraad
    Tonnard, Patrick
    Verpaele, Alex
    Monstrey, Stan
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 123 (02) : 443 - 454
  • [5] Horizontal pillar technique: A single pedicle septum-based approach in reduction mammaplasty with a twist
    Akyurek, Mustafa
    Hafiz, Gunes
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2023, 87 : 33 - 40
  • [6] Inferior and Central Mound Pedicle Breast Reduction in Gigantomastia: A Safe Alternative?
    Bilgen, Fatma
    Ural, Alper
    Bekerecioglu, Mehmet
    JOURNAL OF INVESTIGATIVE SURGERY, 2021, 34 (04) : 401 - 407
  • [7] Is reduction mammaplasty using the central or and/or inferior pedicle a safe and reliable operative technique?
    Strittmatter, H. J.
    Buchen, S.
    Faridi, A.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2008, 68 (05) : 497 - 504
  • [8] Septum-Inferior-Medial (SIM)-Based Pedicle: A Safe Pedicle with Well-Preserved Nipple Sensation for Reduction in Gigantomastia
    Ercan Karacaoglu
    Richard J. Zienowicz
    Aesthetic Plastic Surgery, 2017, 41 : 1 - 9
  • [9] Septum-Inferior-Medial (SIM)-Based Pedicle: A Safe Pedicle with Well-Preserved Nipple Sensation for Reduction in Gigantomastia
    Karacaoglu, Ercan
    Zienowicz, Richard J.
    AESTHETIC PLASTIC SURGERY, 2017, 41 (01) : 1 - 9
  • [10] A new oncoplastic technique with immediate nipple reconstruction for central breast tumors using Wuringer's septum-based flap
    Hamdi, Moustapha
    Marina, Cristina
    De Baerdemaeker, Randy
    Kapila, Ayush K.
    Vanhoeij, Marian
    Giunta, Gabriele
    Zeltzer, Assaf
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (10): : 3690 - 3699