Investigation of matrix effects in nitrogen microwave inductively coupled atmospheric-pressure plasma mass spectrometry (MICAP-MS) for trace element analysis in steels

被引:6
作者
Winckelmann, Alexander [1 ,2 ]
Roik, Janina [1 ]
Recknagel, Sebastian [1 ]
Abad, Carlos [1 ]
You, Zengchao [1 ]
机构
[1] Bundesanstalt Mat Forsch & Prufung BAM, Richard Willstatter Str 11, D-12489 Berlin, Germany
[2] Humboldt Univ, Dept Chem, Brook Taylor Str 2, D-12489 Berlin, Germany
关键词
OPTICAL-EMISSION SPECTROMETRY; ICP-MS; SAMPLES; ALLOY; ARGON;
D O I
10.1039/d3ja00088e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We investigated the performance of nitrogen microwave inductively coupled atmospheric-pressure plasma mass spectrometry (MICAP-MS) under matrix effects and its applicability to trace element analysis in steels. Influences of different gas flows and ion optics on the matrix tolerance are studied, indicating that nebulizer gas flow has the most significant impact. Optimization of ion optics improves matrix tolerance for light elements due to the reduction of the inelastic collisional scattering effect. With optimized operating conditions, MICAP-MS achieves an internal standard intensity recovery of over 90% at an Fe concentration of 500 mg L-1. Even at an Fe concentration of 1 g L-1, the recovery remains above 80%. Three certified reference materials - non-alloy, low-alloy and high-alloy steel - were analyzed using MICAP-MS. The determined mass concentrations of the trace and minor components show metrological compatibility to the reference values. No significant differences are observed between the results obtained with aqueous and matrix-matched calibration, demonstrating the strong matrix tolerance of MICAP-MS, and its promising applicability to steel analysis.
引用
收藏
页码:1253 / 1260
页数:8
相关论文
共 36 条
[1]   Matrix effects in inductively coupled plasma mass spectrometry: A review [J].
Agatemor, Christian ;
Beauchemin, Diane .
ANALYTICA CHIMICA ACTA, 2011, 706 (01) :66-83
[2]   Effect of Trace Elements (Boron and Lead) on the Properties of Gray Cast Iron [J].
Ankamma K. .
Journal of The Institution of Engineers (India): Series D, 2014, 95 (01) :19-26
[3]   Improvement of a technique for localization of steel needles in humans using a SQUID magnetometer [J].
Barbosa, CH ;
Monteiro, EC ;
Lima, EA ;
Santos, SF ;
Cavalcanti, EG ;
Ribeiro, PC .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :677-680
[4]   CAVITY FOR MICROWAVE-INDUCED PLASMAS OPERATED IN HELIUM AND ARGON AT ATMOSPHERIC-PRESSURE [J].
BEENAKKER, CIM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1976, 31 (8-9) :483-486
[5]   ASSESSMENT OF ICP-MS FOR ROUTINE MULTIELEMENT ANALYSIS OF SOIL SAMPLES IN ENVIRONMENTAL TRACE-ELEMENT STUDIES [J].
DOLAN, R ;
VANLOON, J ;
TEMPLETON, D ;
PAUDYN, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (02) :99-105
[6]   ON-SITE ENVIRONMENTAL WATER ANALYSES BY ICP-MS [J].
DUANE, MJ ;
FACCHETTI, S .
SCIENCE OF THE TOTAL ENVIRONMENT, 1995, 172 (2-3) :133-144
[7]   ALTERNATIVES TO ALL-ARGON PLASMAS IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) - AN OVERVIEW [J].
DURRANT, SF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11) :389-392
[8]   The influence of aluminium and silicon on transformation kinetics in low alloy steels [J].
Eldridge, MF ;
Cochrane, RC .
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MICROALLOYING IN STEELS, 1998, 284-2 :217-224
[9]   Micro flow injection ICP-MS analysis of high matrix samples: an investigation of its capability to measure trace elements in iron meteorites [J].
Holdship, Phil ;
Bonnand, Pierre ;
Price, David ;
Watson, Paul .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (11) :1941-1953
[10]   Determination of trace elements in super alloy by ICP-MS [J].
Hu, JY ;
Wang, HZ .
MIKROCHIMICA ACTA, 2001, 137 (3-4) :149-155