Accumulated biomechanical effects of mandibular molar mesialization using clear aligners with auxiliary devices: an iterative finite element analysis

被引:10
作者
Lyu, Xinwei [1 ,2 ,3 ]
Cao, Xing [1 ,2 ,3 ]
Chen, Luxian [1 ,2 ,3 ]
Liu, Yuyao [1 ,2 ,3 ]
Li, Huilin [1 ,2 ,3 ]
Hu, Cheng [1 ,2 ,3 ]
Tan, Jiali [1 ,2 ,3 ]
机构
[1] Sun Yat Sen Univ, Hosp Stomatol, Dept Orthodont, Guangzhou 510055, Peoples R China
[2] Sun Yat Sen Univ, Guangdong Prov Key Lab Stomatol, Guangzhou 510080, Peoples R China
[3] Sun Yat Sen Univ, Guanghua Sch Stomatol, Guangzhou 510080, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite element analysis; Clear aligners; Numerical simulation; Molar mesialization; Long-term tooth movement; Biomechanics; ORTHODONTIC TOOTH MOVEMENT; PERMANENT 1ST MOLAR; PERIODONTAL-LIGAMENT; FORCE; PROTRACTION; RETRACTION; TORQUE; SPACE;
D O I
10.1186/s40510-023-00462-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe biomechanics generated by the clear aligner (CA) material changes continuously during orthodontic tooth movement, but this factor remains unknown during the computer-aid design process and the predictability of molars movement is not as expected. Therefore, the purpose of this study was to propose an iterative finite element method to simulate the long-term biomechanical effects of mandibular molar mesialization (MM) in CA therapy under dual-mechanical systems.MethodsThree groups including CA alone, CA with a button, and CA with a modified lever arm (MLA) were created. Material properties of CA were obtained by in vitro mechanical experiments. MM was conducted by the rebound force exerted by CA material and the mesial elastic force (2N, 30 degrees to the occlusal plane) applied to the auxiliary devices. Stress intensity and distribution on periodontal ligament (PDL), attachment, button and MLA, and displacement of the second molar (M2) during the iterations were recorded.ResultsThere was a significant difference between the initial and cumulative long-term displacement. Specifically, compared to the beginning, the maximum stress of PDL decreased by 90% on average in the intermediate and final steps. The aligner was the main mechanical system at first, and then, the additional system exerted by the button and MLA dominated gradually. The stress of attachments and auxiliary devices is mainly concentrated on their interfaces with the tooth. Additionally, MLA provided a distal tipping and extrusive moment, which was the only group that manifested a total mesial displacement of the root.ConclusionsThe innovatively designed MLA was more effective in reducing undesigned mesial tipping and rotation of M2 than the traditional button and CA alone, which provided a therapeutic method for MM. The proposed iterative method simulated tooth movement by considering the mechanical characteristic of CA and its long-term mechanical force changes, which will facilitate better movement prediction and minimize the failure rate.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Biomechanical analysis of maxillary first molar intrusion using 3D printed personalized device combined with clear aligner: a finite element study and clinical application
    Qin Xue
    Mei Hu
    Minglu Xu
    Xuyang Zhang
    Huaqiao Wang
    Mimi Sun
    Chunjuan Wang
    Yao He
    Clinical Oral Investigations, 29 (5)
  • [32] The effects of aligner anchorage preparation on mandibular first molars during premolar-extraction space closure with clear aligners: A finite element study
    Yang, Yi
    Yang, Ruicong
    Liu, Lu
    Zhang, Xiaoqi
    Jiang, Qingsong
    Fan, Qi
    Zhang, Haoxin
    Long, Hu
    Lai, Wenli
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 164 (02) : 226 - 238
  • [33] Effects of maxillary molar distalization using clear aligners during the mixed dentition and early permanent dentition with 3 types of Class II traction: a three-dimensional finite element analysis
    Yue Li
    Meiying Wu
    Xinyu Xing
    Yumiao Chen
    Chengle Zhang
    Junhan Hu
    Congchong Shi
    BMC Oral Health, 25 (1)
  • [34] Effects of different patterns of movement for correcting a deep curve of Spee with clear aligners on the anterior teeth: a finite element analysis
    Lin Zhu
    Lin Liu
    Wei Wang
    Wen Wen Deng
    BMC Oral Health, 24
  • [35] Effects of Impactor Size on Biomechanical Characteristics of Spinal Cord in Hemicontusion Injury Model Using Finite Element Analysis
    Khuyagbaatar, Batbayar
    Kim, Kyungsoo
    Batbayar, Temuujin
    Kim, Yoon Hyuk
    APPLIED SCIENCES-BASEL, 2020, 10 (12):
  • [36] Effects of different patterns of movement for correcting a deep curve of Spee with clear aligners on the anterior teeth: a finite element analysis
    Zhu, Lin
    Liu, Lin
    Wang, Wei
    Deng, Wen Wen
    BMC ORAL HEALTH, 2024, 24 (01)
  • [37] Biomechanical comparison of locking and non-locking patient-specific mandibular reconstruction plate using finite element analysis
    Zhong, Shengping
    Shi, Qimin
    Sun, Yi
    Yang, Shoufeng
    Van Dessel, Jeroen
    Gu, Yifei
    Chen, Xiaojun
    Lubbers, Heinz-Theo
    Politis, Constantinus
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 124
  • [38] Impact of Molar Distalization with Clear Aligners on Periodontal Ligament Stress and Root Resorption Risk: A Systematic Review of 3D Finite Element Analysis Studies
    Nazeri, Ava
    Castillo Jr, Jose A.
    Ghaffari-Rafi, Arash
    DENTISTRY JOURNAL, 2025, 13 (02)
  • [39] A Novel Mandibular Advancement Device for Treatment of Sleep-Disordered Breathing: Evaluation of Its Biomechanical Effects Using Finite Element Analysis
    Yoon, Jonghun
    Lee, Sang Hwa
    Jeong, Yuhyeong
    Kim, Dong-Hyun
    Shin, Hyun-Il
    Lim, So Yun
    APPLIED SCIENCES-BASEL, 2020, 10 (13):
  • [40] The Effect of Access Cavity Designs and Sizes of Root Canal Preparations on the Biomechanical Behavior of an Endodontically Treated Mandibular First Molar: A Finite Element Analysis
    Saber, Shehabeldin Mohamed
    Hayaty, Dennis Mohamed
    Nawar, Nawar Naguib
    Kim, Hyeon-Cheol
    JOURNAL OF ENDODONTICS, 2020, 46 (11) : 1675 - 1681