Accumulated biomechanical effects of mandibular molar mesialization using clear aligners with auxiliary devices: an iterative finite element analysis

被引:10
作者
Lyu, Xinwei [1 ,2 ,3 ]
Cao, Xing [1 ,2 ,3 ]
Chen, Luxian [1 ,2 ,3 ]
Liu, Yuyao [1 ,2 ,3 ]
Li, Huilin [1 ,2 ,3 ]
Hu, Cheng [1 ,2 ,3 ]
Tan, Jiali [1 ,2 ,3 ]
机构
[1] Sun Yat Sen Univ, Hosp Stomatol, Dept Orthodont, Guangzhou 510055, Peoples R China
[2] Sun Yat Sen Univ, Guangdong Prov Key Lab Stomatol, Guangzhou 510080, Peoples R China
[3] Sun Yat Sen Univ, Guanghua Sch Stomatol, Guangzhou 510080, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite element analysis; Clear aligners; Numerical simulation; Molar mesialization; Long-term tooth movement; Biomechanics; ORTHODONTIC TOOTH MOVEMENT; PERMANENT 1ST MOLAR; PERIODONTAL-LIGAMENT; FORCE; PROTRACTION; RETRACTION; TORQUE; SPACE;
D O I
10.1186/s40510-023-00462-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe biomechanics generated by the clear aligner (CA) material changes continuously during orthodontic tooth movement, but this factor remains unknown during the computer-aid design process and the predictability of molars movement is not as expected. Therefore, the purpose of this study was to propose an iterative finite element method to simulate the long-term biomechanical effects of mandibular molar mesialization (MM) in CA therapy under dual-mechanical systems.MethodsThree groups including CA alone, CA with a button, and CA with a modified lever arm (MLA) were created. Material properties of CA were obtained by in vitro mechanical experiments. MM was conducted by the rebound force exerted by CA material and the mesial elastic force (2N, 30 degrees to the occlusal plane) applied to the auxiliary devices. Stress intensity and distribution on periodontal ligament (PDL), attachment, button and MLA, and displacement of the second molar (M2) during the iterations were recorded.ResultsThere was a significant difference between the initial and cumulative long-term displacement. Specifically, compared to the beginning, the maximum stress of PDL decreased by 90% on average in the intermediate and final steps. The aligner was the main mechanical system at first, and then, the additional system exerted by the button and MLA dominated gradually. The stress of attachments and auxiliary devices is mainly concentrated on their interfaces with the tooth. Additionally, MLA provided a distal tipping and extrusive moment, which was the only group that manifested a total mesial displacement of the root.ConclusionsThe innovatively designed MLA was more effective in reducing undesigned mesial tipping and rotation of M2 than the traditional button and CA alone, which provided a therapeutic method for MM. The proposed iterative method simulated tooth movement by considering the mechanical characteristic of CA and its long-term mechanical force changes, which will facilitate better movement prediction and minimize the failure rate.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Accumulated biomechanical effects of mandibular molar mesialization using clear aligners with auxiliary devices: an iterative finite element analysis
    Xinwei Lyu
    Xing Cao
    Luxian Chen
    Yuyao Liu
    Huilin Li
    Cheng Hu
    Jiali Tan
    Progress in Orthodontics, 24
  • [2] A finite element analysis of the effects of semipontic design on tooth movement during mesialization of the mandibular second molar with clear aligners
    Akan, Burcu Ece Koru
    Kircelli, Beyza Hanciog
    Bozkurt, Aylin Pasagolu
    Gogen, Hakan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2024, 166 (05) : 490 - 502
  • [3] Biomechanical effects of different mandibular movements and torque compensations during mandibular advancement with clear aligners: a finite element analysis
    Wang, Ya
    Daraqel, Baraa
    Wang, Ying
    Yang, Dan
    Dong, Yihan
    Hu, Yun
    Zheng, Leilei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [4] Effects of Mandibular Extractions with Clear Aligners: A Finite Element Analysis
    Feng Q.
    Chu F.
    Chen R.
    Pan X.
    Journal of Shanghai Jiaotong University (Science), 2021, 26 (3) : 377 - 382
  • [5] Different biomechanical effects of clear aligners in closing maxillary and mandibular extraction spaces: Finite element analysis
    Liu, Jun-qi
    Zhu, Guan-yin
    Wang, Yi-gan
    Zhang, Bo
    Yao, Ke
    Zhao, Zhi-he
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 163 (06) : 811 - 824.e2
  • [6] Biomechanical effects of periodontal status on molar sequential distalization with clear aligners: a finite element study
    Ma, Yanning
    Fan, Xinyue
    Liu, Xulin
    Zhang, Mingxin
    Jin, Zuolin
    Gao, Jie
    PROGRESS IN ORTHODONTICS, 2025, 26 (01):
  • [7] Effects of Attachment Orientation and Designed Vertical Movement on Molar Distalisation With Clear Aligners: A Biomechanical Finite Element Study
    Li, Jialun
    Yang, Yi
    He, Xian
    Lai, Wenli
    Long, Hu
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2025, 28 (02) : 296 - 303
  • [8] Different biomechanical effects of clear aligners in bimaxillary space closure under two strong anchorages: finite element analysis
    Liu, Jun-qi
    Zhu, Guan-yin
    Wang, Yi-gan
    Zhang, Bo
    Wang, Shuang-cheng
    Yao, Ke
    Zhao, Zhi-he
    PROGRESS IN ORTHODONTICS, 2022, 23 (01)
  • [9] Different biomechanical effects of clear aligners in bimaxillary space closure under two strong anchorages: finite element analysis
    Jun-qi Liu
    Guan-yin Zhu
    Yi-gan Wang
    Bo Zhang
    Shuang-cheng Wang
    Ke Yao
    Zhi-he Zhao
    Progress in Orthodontics, 23
  • [10] Effects of upper-molar distalization using clear aligners in combination with Class II elastics: a three-dimensional finite element analysis
    Liu, Xulin
    Cheng, Yuxun
    Qin, Wen
    Fang, Shishu
    Wang, Wei
    Ma, Yanning
    Jin, Zuolin
    BMC ORAL HEALTH, 2022, 22 (01)