Favorable outcomes of posterior cruciate-stabilized inserts over ultracongruent inserts in total knee arthroplasty

被引:2
作者
Obana, Kyle K. [1 ]
Wong, Krystin [1 ,2 ]
Shimoda, Brent T. [2 ]
Rimm, Julian [1 ]
Stickley, Christopher D. [4 ]
Nakasone, Cass K. [2 ,3 ]
机构
[1] John A Burns Sch Med, 651 Ilalo St, Honolulu, HI 96813 USA
[2] Straub Med Ctr, Bone & Joint Ctr, 888 South King St, Honolulu, HI 96818 USA
[3] Univ Hawaii, John A Burns Sch Med, Dept Surg, 1356 Lusitana St, Honolulu, HI 96813 USA
[4] Univ Hawaii, John A Burns Sch Med, Dept Anat Biochem & Physiol, 1356 Lusitana St, Honolulu, HI 96813 USA
关键词
Total knee arthroplasty; Range of motion; Clinical outcomes; Ultracongruent; Posterior-stabilized; POLYETHYLENE TIBIAL POST; FUNCTIONAL OUTCOMES; MOTION; RANGE; FRACTURE; KINEMATICS; REPLACEMENTS; OBESITY; DESIGN; WEAR;
D O I
10.1007/s00402-023-04837-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectivePosterior cruciate-stabilized (PS) and ultracongruent (UC) inserts are used during total knee arthroplasty (TKA), but superiority in gaining postoperative knee flexion and functionality remains contested. Therefore, this study compared postoperative outcomes between PS and UC inserts.MethodsA retrospective review evaluated unilateral or bilateral TKAs with PS or UC inserts from August 2011 to March 2020. Nonparametric statistics were performed to evaluate differences in patient demographics, pre- and postknee flexion and Knee Society Knee (KSS-K) and Function Score (KSS-F). Univariate and multivariable regressions were performed to evaluate the influence on postoperative knee flexion >= 120 degrees, presented as odds ratios (OR) and 95% confidence intervals (CI).ResultsPatient demographics were not significantly different between the 577 PS and 399 UC knees evaluated. Postoperatively, a larger proportion of UC knees demonstrated knee flexion < 120 degrees (36.0% vs. 18.6%, p < 0.001) and lower KSS-K (91.0 +/- 8.7 vs. 91.6 +/- 10.3, p < 0.001) and KSS-F (76.8 +/- 21.6 vs. 79.9 +/- 21.6, p = 0.007) than the PS group. The PS group had greater improvement in flexion angle (4.9 degrees +/- 14.9 degrees vs. 1.0 degrees +/- 15.6 degrees, p < 0.001) and KSS-F (27.3 +/- 23.3 vs. 23.1 +/- 25.3, p = 0.007) as compared to that of UC patients. Patients with preoperative flexion < 120 degrees (OR 2.787, CI 2.066-3.761; p < 0.001), higher body mass index (OR 1.033, CI 1.006-1.061; p = 0.017) and UC insert (OR 2.461, CI 1.832-3.307; p < 0.001) were less likely to achieve flexion >= 120 degrees.ConclusionFavorable clinical and functional outcomes were noted in the PS group as compared to UC inserts in TKA. The greater improvement in overall knee flexion may suggest the PS insert may be especially appropriate for patients with lower preoperative range of motion.
引用
收藏
页码:5857 / 5865
页数:9
相关论文
共 57 条
[51]   Variables Determining the Postoperative Knee Range of Motion Following Cruciate-substituting Total Knee Replacement: A Prospective Study [J].
Sahu, Nabin K. ;
Patnaik, Smarajit ;
Nanda, Saurav N. ;
Jain, Mantu .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (08)
[52]  
Sherman William F, 2020, Arthroplast Today, V6, P180, DOI 10.1016/j.artd.2020.03.014
[53]   Higher mid-term revision rates of posterior stabilized compared with cruciate retaining total knee arthroplasties: 133,841 cemented arthroplasties for osteoarthritis in the Netherlands in 2007-2016 [J].
Spekenbrink-Spooren, Anneke ;
Van Steenbergen, Liza N. ;
Denissen, Geke A. W. ;
Swierstra, Bart A. ;
Poolman, Rudolf W. ;
Nelissen, Rob G. H. H. .
ACTA ORTHOPAEDICA, 2018, 89 (06) :640-+
[54]   Cruciate Substituting Implants in Primary Total Knee Arthroplasty [J].
Volkmar, Alexander J. ;
Elrod, Robert ;
Vickery, Justin W. ;
Yang, Charlie C. ;
Polkowski, Gregory G. ;
Martin, J. Ryan .
ADVANCES IN ORTHOPEDICS, 2022, 2022
[55]   Functional Outcomes are Comparable Between Posterior Stabilized and Cruciate-Substituting Total Knee Arthroplasty Designs at Short-Term Follow-up [J].
Yacovelli, Steven ;
Grau, Luis C. ;
Hozack, William J. ;
Courtney, P. Maxwell .
JOURNAL OF ARTHROPLASTY, 2021, 36 (03) :986-990
[56]   The prevalence of posterolateral tibial baseplate overhang: An anatomical CT study [J].
Yokhana, Sanar S. ;
Hamilton, D. Alex ;
Stine, Sasha A. ;
Stimson, Lauren N. ;
Zalikha, Abdul K. ;
Chen, Chaoyang ;
Darwiche, Hussein F. .
JOURNAL OF ORTHOPAEDICS, 2021, 23 :259-263
[57]   Satisfactory Short-Term Results of Navigation-Assisted Gap-Balancing Total Knee Arthroplasty Using Ultracongruent Insert [J].
Yoon, Jung-Ro ;
Yang, Jae-Hyuk .
JOURNAL OF ARTHROPLASTY, 2018, 33 (03) :723-728