Aortic systolic and pulse pressure invasively and non-invasively obtained: Comparative analysis of recording techniques, arterial sites of measurement, waveform analysis algorithms and calibration methods

被引:7
作者
Bia, Daniel [1 ]
Zocalo, Yanina [1 ]
Sanchez, Ramiro [2 ,3 ]
Lev, Gustavo [4 ]
Mendiz, Oscar [4 ]
Pessana, Franco [5 ]
Ramirez, Agustin [6 ]
Cabrera-Fischer, Edmundo, I [6 ]
机构
[1] Univ Republica, Ctr Univ Invest Innovac & Diagnost Arterial CUiiD, Fac Med, Dept Fisiol, Montevideo, Uruguay
[2] Favaloro Fdn, Univ Hosp, Metab Unit, Buenos Aires, Argentina
[3] Favaloro Fdn, Univ Hosp, Hypertens Unit, Buenos Aires, DF, Argentina
[4] Favaloro Fdn, Univ Hosp, Dept Intervent Cardiol, Buenos Aires, DF, Argentina
[5] Favaloro Univ, Engn & Exact Sci Fac, Dept Informat Technol, Buenos Aires, DF, Argentina
[6] IMETTYB Favaloro Univ, CONICET, Buenos Aires, DF, Argentina
关键词
applanation tonometry; calibration; catheterism; central aortic blood pressure; invasive records; non-invasive records; oscillometry; vascular ultrasound; CENTRAL BLOOD-PRESSURE; POINT MOVING AVERAGE; APPLANATION TONOMETRY; ACCURACY; VALIDATION; PEAK; ERROR;
D O I
10.3389/fphys.2023.1113972
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background: The non-invasive estimation of aortic systolic (aoSBP) and pulse pressure (aoPP) is achieved by a great variety of devices, which differ markedly in the: 1) principles of recording (applied technology), 2) arterial recording site, 3) model and mathematical analysis applied to signals, and/or 4) calibration scheme. The most reliable non-invasive procedure to obtain aoSBP and aoPP is not well established.Aim: To evaluate the agreement between aoSBP and aoPP values invasively and non-invasively obtained using different: 1) recording techniques (tonometry, oscilometry/plethysmography, ultrasound), 2) recording sites [radial, brachial (BA) and carotid artery (CCA)], 3) waveform analysis algorithms (e.g., direct analysis of the CCA pulse waveform vs. peripheral waveform analysis using general transfer functions, N-point moving average filters, etc.), 4) calibration schemes (systolic-diastolic calibration vs. methods using BA diastolic and mean blood pressure (bMBP); the latter calculated using different equations vs. measured directly by oscillometry, and 5) different equations to estimate bMBP (i.e., using a form factor of 33% ( "033 "), 41.2% ( "0412 ") or 33% corrected for heart rate ( "033HR ").Methods: The invasive aortic (aoBP) and brachial pressure (bBP) (catheterization), and the non-invasive aoBP and bBP were simultaneously obtained in 34 subjects. Non-invasive aoBP levels were obtained using different techniques, analysis methods, recording sites, and calibration schemes.Results: 1) Overall, non-invasive approaches yielded lower aoSBP and aoPP levels than those recorded invasively. 2) aoSBP and aoPP determinations based on CCA recordings, followed by BA recordings, were those that yielded values closest to those recorded invasively. 3) The "033HR " and "0412 " calibration schemes ensured the lowest mean error, and the "033 " method determined aoBP levels furthest from those recorded invasively. 4) Most of the non-invasive approaches considered overestimated and underestimated aoSBP at low (i.e., 80 mmHg) and high (i.e., 180 mmHg) invasive aoSBP values, respectively. 5) The higher the invasively measured aoPP, the higher the level of underestimation provided by the non-invasive methods.Conclusion: The recording method and site, the mathematical method/model used to quantify aoSBP and aoPP, and to calibrate waveforms, are essential when estimating aoBP. Our study strongly emphasizes the need for methodological transparency and consensus for the non-invasive aoBP assessment.
引用
收藏
页数:21
相关论文
共 49 条
  • [1] Pulse pressure amplification, pressure waveform calibration and clinical applications
    Agnoletti, Davide
    Zhang, Yi
    Salvi, Paolo
    Borghi, Claudio
    Topouchian, Jirar
    Safar, Michel E.
    Blacher, Jacques
    [J]. ATHEROSCLEROSIS, 2012, 224 (01) : 108 - 112
  • [2] Increased reversal and oscillatory shear stress cause smooth muscle contraction-dependent changes in sheep aortic dynamics:: role in aortic balloon pump circulatory support
    Bia, D.
    Zocalo, Y.
    Armentano, R.
    Camus, J.
    de Forteza, E.
    Cabrera-Fischer, E.
    [J]. ACTA PHYSIOLOGICA, 2008, 192 (04) : 487 - 503
  • [3] Physiological Age- and Sex-Related Profiles for Local (Aortic) and Regional (Carotid-Femoral, Carotid-Radial) Pulse Wave Velocity and Center-to-Periphery Stiffness Gradient, with and without Blood Pressure Adjustments: Reference Intervals and Agreement between Methods in Healthy Subjects (3-84 Years)
    Bia, Daniel
    Zocalo, Yanina
    [J]. JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (01) : 1 - 35
  • [4] Billiet E., 2007, ICU MANAG, V7, P12
  • [5] How to assess mean blood pressure properly at the brachial artery level
    Bos, Willem J. W.
    Verrij, Elisabeth
    Vincent, Hieronymus H.
    Westerhof, Berend E.
    Parati, Gianfranco
    van Montfrans, Gert A.
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 (04) : 751 - 755
  • [6] Assessment of Central Arterial Hemodynamics in Children: Comparison of Noninvasive and Invasive Measurements
    Cai, Tommy Y.
    Haghighi, Marjan M.
    Roberts, Philip A.
    Mervis, Jonathan
    Qasem, Ahmad
    Butlin, Mark
    Celermajer, David S.
    Avolio, Alberto
    Skilton, Michael R.
    Ayer, Julian G.
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2021, 34 (02) : 163 - 171
  • [7] Childhood Obesity Associates Haemodynamic and Vascular Changes That Result in Increased Central Aortic Pressure with Augmented Incident and Reflected Wave Components, without Changes in Peripheral Amplification
    Castro, Juan M.
    Garcia-Espinosa, Victoria
    Curcio, Santiago
    Arana, Maite
    Chiesa, Pedro
    Giachetto, Gustavo
    Zocalo, Yanina
    Bia, Daniel
    [J]. INTERNATIONAL JOURNAL OF VASCULAR MEDICINE, 2016, 2016
  • [8] Mean aortic pressure is the geometric mean of systolic and diastolic aortic pressure in resting humans
    Chemla, D
    Antony, I
    Zamani, K
    Nitenberg, A
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (06) : 2278 - 2284
  • [9] Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysis
    Cheng, Hao-Min
    Lang, Dora
    Tufanaru, Catalin
    Pearson, Alan
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (05) : 1867 - 1876
  • [10] Factors That May Impact the Noninvasive Measurement of Central Blood Pressure Compared to Invasive Measurement: The MATCHY Study
    Chi, Chen
    Lu, Yi
    Zhou, Yiwu
    Li, Jiaxin
    Xu, Yawei
    Zhang, Yi
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (09):