Process design for removal of pharmaceuticals in wastewater treatment plants based on predicted no effect concentration (PNEC)

被引:18
作者
Kisielius, Vaidotas [1 ]
Kharel, Suman [1 ]
Skaarup, Jorgen [3 ]
Lauritzen, Britta Sevelsted [3 ]
Lukas, Marcus [4 ]
Bogusz, Aleksandra [5 ]
Szumska, Marlena [5 ]
Bester, Kai [1 ,2 ]
机构
[1] Aarhus Univ, Dept Environm Sci, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
[2] Aarhus Univ, WATEC Ctr Water Technol, Ny Munkegade 120, DK-8000 Aarhus, Denmark
[3] Hillerod Forsyning, Solrodgards 6, DK-3400 Hillerod, Denmark
[4] German Fed Environm Agcy Umweltbundesamt, Schichauweg 58, D-12307 Berlin, Germany
[5] Natl Res Inst IOS, Inst Environm Protect, Krucza 5-11D, PL-00548 Warsaw, Poland
关键词
Wastewater treatment; Micropollutants; Ozone; Granulated activated carbon; No effect level; GRANULAR ACTIVATED CARBON; TRANSFORMATION PRODUCTS; ORGANIC MICROPOLLUTANTS; MUSK FRAGRANCES; CONTRAST-MEDIA; BROWN TROUT; OZONATION; OZONE; CONTAMINANTS; DEGRADATION;
D O I
10.1016/j.cej.2023.146644
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Increasing concern on water contamination by micropollutants like pharmaceuticals fuels the development and implementation of technologies to remove micropollutants from municipal wastewater treatment plants (WWTP). However, often the targets and criteria for process design of such technologies are not clarified. This study was conducted to test whether predicted no-effect concentrations (PNEC) can be used as a design parameter for advanced treatment technologies to achieve pharmaceutical levels in WWTP effluents. This goal is consistent with environmental requirements, currently being discussed both by the Danish authorities and the European goals on zero emissions as documented in the draft of the Urban Wastewater Directive. The effluent of a conventional activated sludge WWTP was treated by ozonation and granular activated carbon (GAC) and monitored for 50 pharmaceuticals and iodinated X-ray contrast media, as well as 23 transformation products. Treatment with GAC alone initially achieved concentrations below PNEC for all targeted compounds, but after treating 3,000 - 5,000 bed volumes, the removal for several compounds decreased and the effluent concentrations for clarithromycin and venlafaxine were no longer below PNEC. Ozonation alone effectively reduced the concentrations of most of the compounds with standard ozone dosing of 0.5 mg O3/mg DOC. However, ozonation was unable to remove bicalutamide and oxazepam to reach target concentrations. The operation of both technologies in combination achieved concentrations of all measured pharmaceuticals below the PNEC (even with ozone concentrations of below 0.5 mg O3/mg DOC). Nonetheless, this study suggests that proper steering of WWTP design via the PNEC values alone is obstructed by lack of reliable primal PNEC data and absence of PNEC references for emerging pollutants and potential biologically active transformation products.
引用
收藏
页数:11
相关论文
共 101 条
[51]   Effects of substrate loading on co-metabolic transformation pathways and removal rates of pharmaceuticals in biofilm reactors br [J].
Liang, Chuanzhou ;
Carvalho, Pedro N. ;
Bester, Kai .
SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 853
[52]   Evaluating the efficiency of advanced wastewater treatment: Target analysis of organic contaminants and (geno-)toxicity assessment tell a different story [J].
Magdeburg, Axel ;
Stalter, Daniel ;
Schliuesener, Michael ;
Ternes, Thomas ;
Oehlmann, Joerg .
WATER RESEARCH, 2014, 50 :35-47
[53]   Multistage ozone and biological treatment system for real wastewater containing antibiotics [J].
Marcelino, Rafaela B. P. ;
Leao, Monica M. D. ;
Lago, Rochel M. ;
Amorim, Camila C. .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2017, 195 :110-116
[54]   Treatment of micropollutants in municipal wastewater: Ozone or powdered activated carbon? [J].
Margot, Jonas ;
Kienle, Cornelia ;
Magnet, Anoys ;
Weil, Mirco ;
Rossi, Luca ;
de Alencastro, Luiz Felippe ;
Abegglen, Christian ;
Thonney, Denis ;
Chevre, Nathalie ;
Schaerer, Michael ;
Barry, D. A. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 461 :480-498
[55]   REVISED METHODS FOR THE SALMONELLA MUTAGENICITY TEST [J].
MARON, DM ;
AMES, BN .
MUTATION RESEARCH, 1983, 113 (3-4) :173-215
[56]   Triclosan changes community composition and selects for specific bacterial taxa in marine periphyton biofilms in low nanomolar concentrations [J].
Martin, Eriksson Karl ;
Kemal, Sanli ;
Henrik, Nilsson Rickard ;
Alexander, Eiler ;
Natalia, Corcoll ;
Henrik, Johansson Carl ;
Thomas, Backhaus ;
Hans, Blanck ;
Erik, Kristiansson .
ECOTOXICOLOGY, 2020, 29 (07) :1083-1094
[57]   Removal of micropollutants through bio-based materials as a transition to circular bioeconomy: Treatment processes involved, perspectives and bottlenecks [J].
Mathew, Annu T. ;
Saravanakumar, M. P. .
ENVIRONMENTAL RESEARCH, 2022, 214
[58]   Toxicities of 48 pharmaceuticals and their freshwater and marine environmental assessment in northwestern France [J].
Minguez, Laetitia ;
Pedelucq, Julie ;
Farcy, Emilie ;
Ballandonne, Celine ;
Budzinski, Helene ;
Halm-Lemeille, Marie-Pierre .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (06) :4992-5001
[59]   Removal of pharmaceuticals from wastewater of health care facilities [J].
Mousel, Daniele ;
Bastian, Daniel ;
Firk, Julian ;
Palmowski, Laurence ;
Pinnekamp, Johannes .
SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 751
[60]   Removal of APIs and bacteria from hospital wastewater by MBR plus O3, O3 + H2O2, PAC or ClO2 [J].
Nielsen, U. ;
Hastrup, C. ;
Klausen, M. M. ;
Pedersen, B. M. ;
Kristensen, G. H. ;
Jansen, J. L. C. ;
Bak, S. N. ;
Tuerk, J. .
WATER SCIENCE AND TECHNOLOGY, 2013, 67 (04) :854-862