Process design for removal of pharmaceuticals in wastewater treatment plants based on predicted no effect concentration (PNEC)

被引:15
作者
Kisielius, Vaidotas [1 ]
Kharel, Suman [1 ]
Skaarup, Jorgen [3 ]
Lauritzen, Britta Sevelsted [3 ]
Lukas, Marcus [4 ]
Bogusz, Aleksandra [5 ]
Szumska, Marlena [5 ]
Bester, Kai [1 ,2 ]
机构
[1] Aarhus Univ, Dept Environm Sci, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
[2] Aarhus Univ, WATEC Ctr Water Technol, Ny Munkegade 120, DK-8000 Aarhus, Denmark
[3] Hillerod Forsyning, Solrodgards 6, DK-3400 Hillerod, Denmark
[4] German Fed Environm Agcy Umweltbundesamt, Schichauweg 58, D-12307 Berlin, Germany
[5] Natl Res Inst IOS, Inst Environm Protect, Krucza 5-11D, PL-00548 Warsaw, Poland
关键词
Wastewater treatment; Micropollutants; Ozone; Granulated activated carbon; No effect level; GRANULAR ACTIVATED CARBON; TRANSFORMATION PRODUCTS; ORGANIC MICROPOLLUTANTS; MUSK FRAGRANCES; CONTRAST-MEDIA; BROWN TROUT; OZONATION; OZONE; CONTAMINANTS; DEGRADATION;
D O I
10.1016/j.cej.2023.146644
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Increasing concern on water contamination by micropollutants like pharmaceuticals fuels the development and implementation of technologies to remove micropollutants from municipal wastewater treatment plants (WWTP). However, often the targets and criteria for process design of such technologies are not clarified. This study was conducted to test whether predicted no-effect concentrations (PNEC) can be used as a design parameter for advanced treatment technologies to achieve pharmaceutical levels in WWTP effluents. This goal is consistent with environmental requirements, currently being discussed both by the Danish authorities and the European goals on zero emissions as documented in the draft of the Urban Wastewater Directive. The effluent of a conventional activated sludge WWTP was treated by ozonation and granular activated carbon (GAC) and monitored for 50 pharmaceuticals and iodinated X-ray contrast media, as well as 23 transformation products. Treatment with GAC alone initially achieved concentrations below PNEC for all targeted compounds, but after treating 3,000 - 5,000 bed volumes, the removal for several compounds decreased and the effluent concentrations for clarithromycin and venlafaxine were no longer below PNEC. Ozonation alone effectively reduced the concentrations of most of the compounds with standard ozone dosing of 0.5 mg O3/mg DOC. However, ozonation was unable to remove bicalutamide and oxazepam to reach target concentrations. The operation of both technologies in combination achieved concentrations of all measured pharmaceuticals below the PNEC (even with ozone concentrations of below 0.5 mg O3/mg DOC). Nonetheless, this study suggests that proper steering of WWTP design via the PNEC values alone is obstructed by lack of reliable primal PNEC data and absence of PNEC references for emerging pollutants and potential biologically active transformation products.
引用
收藏
页数:11
相关论文
共 101 条
  • [91] Swiss Federal Council (Schweizerische Bundesrat), 2015, Gewaesserschutzverordnung
  • [92] Impact of intermittent feeding on polishing of micropollutants by moving bed biofilm reactors (MBBR)
    Tang, Kai
    Rosborg, Peter
    Rasmussen, Emma S.
    Hambly, Adam
    Madsen, Michael
    Jensen, Niels M.
    Hansen, Aviaja A.
    Sund, Christina
    Andersen, Heidi G.
    Torresi, Elena
    Kragelund, Caroline
    Andersen, Henrik R.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2021, 403
  • [93] Ozonation:: a tool for removal of pharmaceuticals, contrast media and musk fragrances from wastewater?
    Ternes, TA
    Stüber, J
    Herrmann, N
    McDowell, D
    Ried, A
    Kampmann, M
    Teiser, B
    [J]. WATER RESEARCH, 2003, 37 (08) : 1976 - 1982
  • [94] Copper ecological risk assessment using DGT technique and PNEC: A case study in the Brazilian coast
    Umbria-Salinas, Karelys
    Valero, Astolfo
    Martins, Samantha Eslava
    Wallner-Kersanach, Monica
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2021, 403
  • [95] Removal of pharmaceuticals from a WWTP secondary effluent by ultrafiltration/reverse osmosis followed by electrochemical oxidation of the RO concentrate
    Urtiaga, A. M.
    Perez, G.
    Ibanez, R.
    Ortiz, I.
    [J]. DESALINATION, 2013, 331 : 26 - 34
  • [96] Simultaneous ozone and granular activated carbon for advanced treatment of micropollutants in municipal wastewater effluent
    Vatankhah, Hooman
    Riley, Stephanie M.
    Murray, Conner
    Quinones, Oscar
    Steirer, K. Xerxes
    Dickenson, Eric R. V.
    Bellona, Christopher
    [J]. CHEMOSPHERE, 2019, 234 : 845 - 854
  • [97] Systematic Review of Toxicity Removal by Advanced Wastewater Treatment Technologies via Ozonation and Activated Carbon
    Volker, Johannes
    Stapf, Michael
    Miehe, Ulf
    Wagner, Martin
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (13) : 7215 - 7233
  • [98] VonSonntag C, 2012, CHEMISTRY OF OZONE IN WATER AND WASTEWATER TREATMENT: FROM BASIC PRINCIPLES TO APPLICATIONS, P1
  • [99] Use of QSAR and SSD methods on deriving predicted no-effect concentrations in seawater and sediment for ten individual parent- and alkyl-PAHs and a case study on the assessment of their ecological risks from the Dalian Bay, China
    Wang, Ying
    Liu, Xing
    Cong, Yi
    Fei, Jin
    Wang, Juying
    Zhang, Dian
    Liu, Liang
    Mu, Jingli
    Yao, Ziwei
    [J]. ACTA OCEANOLOGICA SINICA, 2020, 39 (12) : 95 - 105
  • [100] The role of membrane processes in municipal wastewater reclamation and reuse
    Wintgens, T
    Melin, T
    Schäfer, A
    Khan, S
    Muston, M
    Bixio, D
    Thoeye, C