Development of Conducting Biopolymer-Based Biosensor for Heavy-Metal Ion Detection

被引:1
|
作者
Dutta, Shreya [1 ]
Butola, Ravi [2 ]
Singh, Bhupendra Pratap [3 ]
Chandra, Prakash [1 ]
机构
[1] Delhi Technol Univ, Dept Biotechnol, Delhi 110042, India
[2] GGSIP Univ, Univ Sch Automat & Robot USAR, East Delhi Campus, Delhi 110092, India
[3] Cent Univ Haryana, Dept Environm Studies, Mahendergarh 123031, Haryana, India
关键词
CONDUCTOMETRIC BIOSENSOR; COMPOSITE; ELECTRODE; VOLTAMMETRY; FABRICATION; POLYMERS; UREASE;
D O I
10.1149/2162-8777/ad041d
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The increasing concentration of heavy metals in the water ecosystems has been a noteworthy concern nowadays. This has accounted for various diseases, due to the bioaccumulation in the human body. We propose a biocompatible, non-toxic technique for the identification of heavy metal ions from the contaminated aquatic samples. A urease biosensor, having interpenetrating network of Katira-cl-Acrylic Acid (AAc)/Polyaniline (PANI) hydrogel composite deposited onto the indium tin oxide (ITO). Enhanced hydrogel conductivity due to the incorporation of PANI has been gained by the interfacial polymerization of katira gum and aniline monomer in the ratio of 2:1 using N,N'-MBA and APS as cross-linker and initiator respectively. Structural, morphological and electrochemical characterization of PANI/ITO, Katira-cl-AAc/PANI/ITO and Urease/Katira-cl-AAc/PANI/ITO electrode conducted using SEM, FT-IR, TGA, UV spectrometry, cyclic voltammetry. A comparative study of different concentrations of cadmium, cobalt and Mercury, has been done. The inhibition rates were found to be in the order of Hg2+ > Cd2+ > Co2+. Enzyme inhibition observed in the concentration range from 1.8 mM to 5 mM, 0.1 mM to 2 mM and 0.1 mM to 5 mM respectively. Urease/Katira-cl-AAc/PANI/ITO, exhibits greater stability, enhanced sensitivity and wide-range of detection limit (200 to 270 ng l(-1)) with a shelf life.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Biopolymer-Based Gel Electrolytes for Advanced Zinc Ion Batteries: Progress and Perspectives
    Jia, Renjie
    Wei, Chuanliang
    Ma, Buxin
    Li, Linhao
    Yang, Chunhui
    Wang, Bingbing
    Tan, Liwen
    Feng, Jinkui
    ADVANCED FUNCTIONAL MATERIALS, 2025, 35 (12)
  • [42] Environmental Sustainability of Natural Biopolymer-Based Electrolytes for Lithium Ion Battery Applications
    Huang, Jing
    Wang, Sijun
    Chen, Junqing
    Chen, Chaoji
    Lizundia, Erlantz
    ADVANCED MATERIALS, 2025,
  • [43] The development of biopolymer-based nanostructured materials plastics, gels, IPNs, and nanofoams
    Van Soest, JJG
    FEEDSTOCKS FOR THE FUTURE: RENEWABLES FOR THE PRODUCTION OF CHEMICALS AND MATERIALS, 2006, 921 : 288 - 303
  • [44] Heavy metal ion detection using a capacitive micromechanical biosensor array for environmental monitoring
    Tsekenis, G.
    Filippidou, M. K.
    Chatzipetrou, M.
    Tsouti, V.
    Zergioti, I.
    Chatzandroulis, S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 628 - 635
  • [45] Applications of protein-based capacitive Biosensors for the detection of heavy-metal ions
    Mortari, Alessia
    Browns, Nigel L.
    Geczy, Carolyn
    Coster, Hans G. L.
    Valenzuela, Stella M.
    Martin, Donald
    Csoregi, Elisabeth
    2006 INTERNATIONAL CONFERENCE ON NANOSCIENCE AND NANOTECHNOLOGY, VOLS 1 AND 2, 2006, : 304 - +
  • [46] COMPARISON OF MICROBIAL TESTS FOR THE DETECTION OF HEAVY-METAL GENOTOXICITY
    CODINA, JC
    PEREZTORRENTE, C
    PEREZGARCIA, A
    CAZORLA, FM
    DEVICENTE, A
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1995, 29 (02) : 260 - 265
  • [47] Review of the application of quantum dots in the heavy-metal detection
    Zou, Ling
    Gu, Zhaohui
    Sun, Ming
    TOXICOLOGICAL AND ENVIRONMENTAL CHEMISTRY, 2015, 97 (3-4): : 477 - 490
  • [48] ELECTROCHEMICAL METHOD FOR THE DETECTION OF HEAVY-METAL IONS IN WATERS
    CNOBLOCH, H
    KELLERMANN, W
    NISCHIK, H
    PANTEL, K
    STURM, FV
    SIEMENS FORSCHUNGS-UND ENTWICKLUNGSBERICHTE-SIEMENS RESEARCH AND DEVELOPMENT REPORTS, 1979, 8 (04): : 221 - 226
  • [49] Distinct and sensitive detection of heavy-metal divalent cations using a genetically engineered ion channel
    Kasianowicz, JJ
    Burden, DL
    Han, LC
    Cheley, S
    Bayley, H
    BIOPHYSICAL JOURNAL, 1997, 72 (02) : THAM7 - THAM7
  • [50] Phosphorescent chemosensors based on heavy-metal complexes
    Zhao, Qiang
    Li, Fuyou
    Huang, Chunhui
    CHEMICAL SOCIETY REVIEWS, 2010, 39 (08) : 3007 - 3030