Development of Conducting Biopolymer-Based Biosensor for Heavy-Metal Ion Detection

被引:1
|
作者
Dutta, Shreya [1 ]
Butola, Ravi [2 ]
Singh, Bhupendra Pratap [3 ]
Chandra, Prakash [1 ]
机构
[1] Delhi Technol Univ, Dept Biotechnol, Delhi 110042, India
[2] GGSIP Univ, Univ Sch Automat & Robot USAR, East Delhi Campus, Delhi 110092, India
[3] Cent Univ Haryana, Dept Environm Studies, Mahendergarh 123031, Haryana, India
关键词
CONDUCTOMETRIC BIOSENSOR; COMPOSITE; ELECTRODE; VOLTAMMETRY; FABRICATION; POLYMERS; UREASE;
D O I
10.1149/2162-8777/ad041d
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The increasing concentration of heavy metals in the water ecosystems has been a noteworthy concern nowadays. This has accounted for various diseases, due to the bioaccumulation in the human body. We propose a biocompatible, non-toxic technique for the identification of heavy metal ions from the contaminated aquatic samples. A urease biosensor, having interpenetrating network of Katira-cl-Acrylic Acid (AAc)/Polyaniline (PANI) hydrogel composite deposited onto the indium tin oxide (ITO). Enhanced hydrogel conductivity due to the incorporation of PANI has been gained by the interfacial polymerization of katira gum and aniline monomer in the ratio of 2:1 using N,N'-MBA and APS as cross-linker and initiator respectively. Structural, morphological and electrochemical characterization of PANI/ITO, Katira-cl-AAc/PANI/ITO and Urease/Katira-cl-AAc/PANI/ITO electrode conducted using SEM, FT-IR, TGA, UV spectrometry, cyclic voltammetry. A comparative study of different concentrations of cadmium, cobalt and Mercury, has been done. The inhibition rates were found to be in the order of Hg2+ > Cd2+ > Co2+. Enzyme inhibition observed in the concentration range from 1.8 mM to 5 mM, 0.1 mM to 2 mM and 0.1 mM to 5 mM respectively. Urease/Katira-cl-AAc/PANI/ITO, exhibits greater stability, enhanced sensitivity and wide-range of detection limit (200 to 270 ng l(-1)) with a shelf life.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Development of Biopolymer and Conducting Polymer-Based Optical Sensors for Heavy Metal Ion Detection
    Ramdzan, Nur Syahira Md
    Fen, Yap Wing
    Anas, Nur Ain Asyiqin
    Omar, Nur Alia Sheh
    Saleviter, Silvan
    MOLECULES, 2020, 25 (11):
  • [2] A New Method for Heavy Metals and Aluminium Detection Using Biopolymer-Based Optical Biosensor
    Wong, Ling Shing
    Wong, Chee Sien
    IEEE SENSORS JOURNAL, 2015, 15 (01) : 471 - 475
  • [3] A CNN-Based Method for Heavy-Metal Ion Detection
    Zhang, Jian
    Chen, Feng
    Zou, Ruiyu
    Liao, Jianjun
    Zhang, Yonghui
    Zhu, Zeyu
    Yan, Xinyue
    Jiang, Zhiwen
    Tan, Fangzhou
    APPLIED SCIENCES-BASEL, 2023, 13 (07):
  • [4] APPLICATION OF UREASE CONDUCTOMETRIC BIOSENSOR FOR HEAVY-METAL ION DETERMINATION
    ZHYLYAK, GA
    DZYADEVICH, SV
    KORPAN, YI
    SOLDATKIN, AP
    ELSKAYA, AV
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 145 - 148
  • [5] Phytochelatin modified electrode surface as a sensitive heavy-metal ion biosensor
    Adam, V
    Zehnalek, J
    Petrlova, J
    Potesil, D
    Sures, B
    Trnkova, L
    Jelen, F
    Vitecek, J
    Kizek, R
    SENSORS, 2005, 5 (1-2) : 70 - 84
  • [6] Development of biopolymer adsorbents for heavy metal ion separations
    Rorrer, GL
    Hsien, TY
    1996 TAPPI MINIMUM EFFLUENT MILLS SYMPOSIUM, 1996, : 261 - 267
  • [7] Application of Biopolymer-based Adsorbents in Removal of Heavy Metals
    Xiao, Min
    Hu, Jiancan
    Liu, Wenli
    Nie, Fengming
    ADVANCES IN TEXTILE ENGINEERING AND MATERIALS IV, 2014, 1048 : 373 - 377
  • [8] Synthesis and characterization of biopolymer-based electrical conducting graft copolymers
    Tiwari, Ashutosh
    Singh, S. P.
    JOURNAL OF APPLIED POLYMER SCIENCE, 2008, 108 (02) : 1169 - 1177
  • [9] Synthesis and characterization of biopolymer-based electrical conducting graft copolymers
    Tiwari, Ashutosh
    Singh, S.P.
    Journal of Applied Polymer Science, 2008, 108 (02): : 1169 - 1177
  • [10] Sustainable Biopolymer-Based Electrochemical Sensors for Trace Heavy Metal Determination in Water: A Comprehensive Review
    Helim, Rabiaa
    Zazoua, Ali
    Korri-Youssoufi, Hafsa
    Chemosensors, 2024, 12 (12)