Can Single Cell Respiration be Measured by Scanning Electrochemical Microscopy (SECM)?

被引:9
作者
Cremin, Kelsey [1 ,2 ]
Meloni, Gabriel N. [3 ,4 ]
Valavanis, Dimitrios [4 ]
Soyer, Orkun S. [2 ,3 ]
Unwin, Patrick R. [3 ,4 ]
机构
[1] Univ Warwick, Mol Analyt Sci Ctr Doctoral Training MAS CDT, Dept Chem, Bioelect Engn Innovat Hub, Coventry CV4 7AL, England
[2] Univ Warwick, Sch Life Sci, Coventry CV4 7AL, England
[3] Univ Warwick, Bioelect Engn Innovat Hub, Coventry CV4 7AL, England
[4] Univ Warwick, Dept Chem, Coventry CV4 7AL, England
来源
ACS MEASUREMENT SCIENCE AU | 2023年 / 3卷 / 05期
基金
英国工程与自然科学研究理事会;
关键词
SECM; Single cell measurement; OCR; FEM simulations; Respiration; ION CONDUCTANCE MICROSCOPY; OXYGEN-CONSUMPTION; LIVING CELLS; QUANTITATIVE VISUALIZATION; MODE; DIFFUSION; REDUCTION; FEEDBACK; PROBE; PERMEABILITY;
D O I
10.1021/acsmeasuresciau.3c00019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ultramicroelectrode (UME), or, equivalently, microelectrode,probesare increasingly used for single-cell measurements of cellular propertiesand processes, including physiological activity, such as metabolicfluxes and respiration rates. Major challenges for the sensitivityof such measurements include: (i) the relative magnitude of cellularand UME fluxes (manifested in the current); and (ii) issues aroundthe stability of the UME response over time. To explore the extentto which these factors impact the precision of electrochemical cellularmeasurements, we undertake a systematic analysis of measurement conditionsand experimental parameters for determining single cell respirationrates via the oxygen consumption rate (OCR) in single HeLa cells.Using scanning electrochemical microscopy (SECM), with a platinumUME as the probe, we employ a self-referencing measurement protocol,rarely employed in SECM, whereby the UME is repeatedly approachedfrom bulk solution to a cell, and a short pulse to oxygen reductionreaction (ORR) potential is performed near the cell and in bulk solution.This approach enables the periodic tracking of the bulk UME responseto which the near-cell response is repeatedly compared (referenced)and also ensures that the ORR near the cell is performed only briefly,minimizing the effect of the electrochemical process on the cell.SECM experiments are combined with a finite element method (FEM) modelingframework to simulate oxygen diffusion and the UME response. Takinga realistic range of single cell OCR to be 1 x 10(-18) to 1 x 10(-16) mol s(-1), resultsfrom the combination of FEM simulations and self-referencing SECMmeasurements show that these OCR values are at, or below, the presentdetection sensitivity of the technique. We provide a set of model-basedsuggestions for improving these measurements in the future but highlightthat extraordinary improvements in the stability and precision ofSECM measurements will be required if single cell OCR measurementsare to be realized.
引用
收藏
页码:361 / 370
页数:10
相关论文
共 74 条
  • [1] Electrochemical Nanoprobes for Single-Cell Analysis
    Actis, Paolo
    Tokar, Sergiy
    Clausmeyer, Jan
    Babakinejad, Babak
    Mikhaleva, Sofya
    Cornut, Renaud
    Takahashi, Yasufumi
    Cordoba, Ainara Lopez
    Novak, Pavel
    Shevchuck, Andrew I.
    Dougan, Jennifer A.
    Kazarian, Sergei G.
    Gorelkin, Petr V.
    Erofeev, Alexander S.
    Yaminsky, Igor V.
    Unwin, Patrick R.
    Schuhmann, Wolfgang
    Klenerman, David
    Rusakov, Dmitri A.
    Sviderskaya, Elena V.
    Korchev, Yuri E.
    [J]. ACS NANO, 2014, 8 (01) : 875 - 884
  • [2] Primordial oscillations in life: Direct observation of glycolytic oscillations in individual HeLa cervical cancer cells
    Amemiya, Takashi
    Shibata, Kenichi
    Itoh, Yoshihiro
    Itoh, Kiminori
    Watanabe, Masatoshi
    Yamaguchi, Tomohiko
    [J]. CHAOS, 2017, 27 (10)
  • [3] [Anonymous], 2005, ANAL CHEM, DOI [10.5189/revpolarography.15.177, DOI 10.5189/REVPOLAROGRAPHY.15.177]
  • [4] Oxygen reduction on platinum electrode coated with Nafion®
    Ayad, A
    Naimi, Y
    Bouet, J
    Fauvarque, JF
    [J]. JOURNAL OF POWER SOURCES, 2004, 130 (1-2) : 50 - 55
  • [5] Bard A. J., 2012, SCANNING ELECTROCHEM, P96
  • [6] SCANNING ELECTROCHEMICAL MICROSCOPY .12. THEORY AND EXPERIMENT OF THE FEEDBACK MODE WITH FINITE HETEROGENEOUS ELECTRON-TRANSFER KINETICS AND ARBITRARY SUBSTRATE SIZE
    BARD, AJ
    MIRKIN, MV
    UNWIN, PR
    WIPF, DO
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (04) : 1861 - 1868
  • [7] SCANNING ELECTROCHEMICAL MICROSCOPY - INTRODUCTION AND PRINCIPLES
    BARD, AJ
    FAN, FRF
    KWAK, J
    LEV, O
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (02) : 132 - 138
  • [8] Chemically imaging living cells by scanning electrochemical microscopy
    Bard, Allen J.
    Li, Xiao
    Zhan, Wei
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 22 (04) : 461 - 472
  • [9] Scanning electrochemical microscopy (SECM) as a probe of transfer processes in two-phase systems: Theory and experimental applications of SECM-induced transfer with arbitrary partition coefficients, diffusion coefficients, and interfacial kinetics
    Barker, AL
    Macpherson, JV
    Slevin, CJ
    Unwin, PR
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (09): : 1586 - 1598
  • [10] Oxygen tolerance and coupling of mitochondrial electron transport
    Campian, JL
    Qian, MQ
    Gao, XH
    Eaton, JW
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 2004, 279 (45) : 46580 - 46587