Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study

被引:18
作者
Zhao, Yaoyu [1 ,2 ,3 ]
Liao, Yilin [1 ,2 ,3 ]
Wu, Xinyu [1 ,2 ]
Zhang, Yufeng [1 ,2 ,4 ]
Shi, Bin [3 ]
Yan, Qi [1 ,2 ,3 ,5 ]
机构
[1] Wuhan Univ, State Key Lab Breeding Base Basic Sci Stomatol Hub, Wuhan, Peoples R China
[2] Wuhan Univ, Hosp Stomatol, Sch, Key Lab Oral Biomed, Wuhan, Peoples R China
[3] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, Wuhan, Peoples R China
[4] Wuhan Univ, Med Res Inst, Sch Med, Wuhan, Peoples R China
[5] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 237 Luoyu Rd, Wuhan 430079, Peoples R China
关键词
Dental implant; Robot-guided surgery; Fiducial marker; In vitro study; Computer assisted implant surgery; Edentulous jaw; COMPUTER-AIDED SURGERY; REGISTRATION; NAVIGATION; PLACEMENT;
D O I
10.1016/j.jdent.2023.104529
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Robot-guided implant placement based on the screw marker-assisted registration technique has been applied in dentistry. This study aimed to identify the optimal number and distribution of fiducial markers for robot-guided implant placement in edentulous mandibular phantoms.Methods: Four implants were digitally planned and placed in edentulous mandibular phantoms under robotic guidance. Different numbers of fiducial markers (3, 4, 5, or 6) and distribution patterns (dispersed or localized) were used to register the robotic system. Platform, apex, and angular deviations were measured between the planned and actual implant positions using different numbers and distributions of fiducial markers.Results: Inserting six fiducial markers resulted in optimal implant position accuracy at the platform (0.53 +/- 0.19 mm) and apex (0.59 +/- 0.2 mm) deviations. However, the angular deviation did not differ significantly between different numbers of fiducial markers. Furthermore, the implant position accuracy did not differ significantly between the dispersed and localized distributions of fiducial markers.Conclusion: In robot-guided implant placement for edentulous mandibular arches, the insertion of six fiducial markers significantly increases the implant placement accuracy.Clinical Significance: The findings of this in vitro study may serve as a reference for clinicians to determine the optimal placement of fiducial markers and to facilitate the clinical application of robot-guided systems for implant placement in edentulous patients. Further clinical studies are necessary to confirm these findings.
引用
收藏
页数:6
相关论文
共 25 条
  • [1] COMPUTER-ASSISTED 3-DIMENSIONAL PLANNING IN CRANIOFACIAL SURGERY
    ALTOBELLI, DE
    KIKINIS, R
    MULLIKEN, JB
    CLINE, H
    LORENSEN, W
    JOLESZ, F
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 92 (04) : 576 - 585
  • [2] Bai S Z, 2021, Zhonghua Kou Qiang Yi Xue Za Zhi, V56, P170, DOI 10.3760/cma.j.cn112144-20210107-00008
  • [3] Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches
    Bolding, Scotty L.
    Reebye, Uday N.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04) : 639 - 647
  • [4] Complete-Arch Implant Rehabilitation with the Aid of Computer-Assisted Implant Surgery and Transitional Implants: A New Digital Approach
    Doliveux, Simon
    Jamjoom, Faris Z.
    Albahri, Rami
    Rousson, Dominique D.
    Hamilton, Adam
    El Kholy, Karim
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (01) : 74 - 80
  • [5] Effect of the Configurations of Fiducial Markers on the Accuracy of Surgical Navigation in Zygomatic Implant Placement: An In Vitro Study
    Fan, Shengchi
    Hung, Kuofeng
    Bornstein, Michael M.
    Huang, Wei
    Wang, Feng
    Wu, Yiqun
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (01) : 85 - 90
  • [6] Garber D A, 1995, Compend Contin Educ Dent, V16, P798
  • [7] Advantages and disadvantages of implant navigation surgery. A systematic review
    Gargallo-Albiola, Jordi
    Barootchi, Shayan
    Salomo-Coll, Oscar
    Wang, Hom-lay
    [J]. ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2019, 225 : 1 - 10
  • [8] A comparison of computer-aided surgery registration methods for endoscopic sinus surgery
    Hardy, SM
    Melroy, C
    White, DR
    Dubin, M
    Senior, B
    [J]. AMERICAN JOURNAL OF RHINOLOGY, 2006, 20 (01): : 48 - 52
  • [9] HASSFELD S, 1995, INT J ORAL MAX SURG, V24, P111
  • [10] A NONINVASIVE, REATTACHABLE SKULL FIDUCIAL MARKER SYSTEM - TECHNICAL NOTE
    HOWARD, MA
    DOBBS, MB
    SIMONSON, TM
    LAVELLE, WE
    GRANNER, MA
    [J]. JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 372 - 376