Comparison of the Accuracy of 2D and 3D Templating for Revision Total Hip Replacement

被引:1
作者
Winter, Philipp [1 ]
Fritsch, Ekkehard [1 ]
Konig, Jochem [2 ]
Wolf, Milan [1 ]
Landgraeber, Stefan [1 ]
Orth, Patrick [1 ]
机构
[1] Univ Saarland, Dept Orthopaed Surg, Kirrberger Str, D-66421 Homburg, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Med Biostat Epidemiol & Informat, Univ Med Ctr, D-55131 Mainz, Germany
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 03期
关键词
revision arthroplasty; hip (joint); reinforcement cage; Burch Schneider; 2D; 3D; computed tomography; ARTHROPLASTY; MAGNIFICATION; PLACEMENT; REASONS; DEFECT;
D O I
10.3390/jpm13030510
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Introduction: Revision hip arthroplasty is a challenging surgical procedure, especially in cases of advanced acetabular bone loss. Accurate preoperative planning can prevent complications such as periprosthetic fractures or aseptic loosening. To date, the accuracy of three-dimensional (3D) versus two-dimensional (2D) templating has been evaluated only in primary hip and knee arthroplasty. Methods: We retrospectively investigated the accuracy of 3D personalized planning of reinforcement cages (Burch Schneider) in 27 patients who underwent revision hip arthroplasty. Personalized 3D modeling and positioning of the reinforcement cages were performed using computed tomography (CT) of the pelvis of each patient and 3D templates of the implant. To evaluate accuracy, the sizes of the reinforcement cages planned in 2D and 3D were compared with the sizes of the finally implanted cages. Factors that may potentially influence planning accuracy such as gender and body mass index (BMI) were analyzed. Results: There was a significant difference (p = 0.003) in the accuracy of correct size prediction between personalized 3D templating and 2D templating. Personalized 3D templating predicted the exact size of the reinforcement cage in 96.3% of the patients, while the exact size was predicted in only 55.6% by 2D templating. Regarding gender and BMI, no statistically significant differences in planning accuracy either for 2D or 3D templating were observed. Conclusion: Personalized 3D planning of revision hip arthroplasty using Burch Schneider reinforcement cages leads to greater accuracy in the prediction of the required size of implants than conventional 2D templating.
引用
收藏
页数:11
相关论文
共 30 条
  • [1] Augmented Reality for Acetabular Component Placement in Direct Anterior Total Hip Arthroplasty
    Alexander, Clayton
    Loeb, Alexander E.
    Fotouhi, Javad
    Navab, Nassir
    Armand, Mehran
    Khanuja, Harpal S.
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (06) : 1636 - +
  • [2] [Anonymous], OB OV
  • [3] Inaccuracies in the Use of Magnification Markers in Digital Hip Radiographs
    Archibeck, Michael J.
    Cummins, Tamara
    Tripuraneni, Krishna R.
    Carothers, Joshua T.
    Murray-Krezan, Cristina
    Hattab, Mohammad
    White, Richard E., Jr.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (08) : 1812 - 1817
  • [4] Medical 3D Printing Cost-Savings in Orthopedic and Maxillofacial Surgery: Cost Analysis of Operating Room Time Saved with 3D Printed Anatomic Models and Surgical Guides
    Ballard, David H.
    Mills, Patrick
    Duszak, Richard, Jr.
    Weisman, Jeffery A.
    Rybicki, Frank J.
    Woodard, Pamela K.
    [J]. ACADEMIC RADIOLOGY, 2020, 27 (08) : 1103 - 1113
  • [5] Barrack RL, 2004, CLIN ORTHOP RELAT R, P32
  • [6] Berend ME, 2018, BONE JOINT J, V100B, P50, DOI [10.1302/0301-620X.100B1.BJJ-2017-0362.R1, 10.1302/0301-620X.10061.BJJ-2017-0362.R1]
  • [7] Comparison of the accuracy of 2D and 3D templating methods for planning primary total hip replacement: a systematic review and meta-analysis
    Bishi, Habeeb
    Smith, Joshua B., V
    Asopa, Vipin
    Field, Richard E.
    Sochart, David H.
    Wang, Chao
    [J]. EFORT OPEN REVIEWS, 2022, 7 (01) : 70 - 83
  • [8] Acetabular custom-made implants for severe acetabular bone defect in revision total hip arthroplasty: a systematic review of the literature
    Chiarlone, Francesco
    Zanirato, Andrea
    Cavagnaro, Luca
    Alessio-Mazzola, Mattia
    Felli, Lamberto
    Burastero, Giorgio
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (03) : 415 - 424
  • [9] Preoperative planning for primary total hip arthroplasty
    Della Valle, AG
    Padgett, DE
    Salvati, EA
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2005, 13 (07) : 455 - 462
  • [10] A comparison of four systems for calibration when templating for total hip replacement with digital radiography
    Franken, M.
    Grimm, B.
    Heyligers, I.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01): : 136 - 141