A mathematical approach to estimate micro-displacement of a dental implant using electromagnetic Frequency Response Analysis

被引:2
作者
Dhatrak, Pankaj [1 ]
Bhadri, Karan [1 ]
Karnik, Niharika [1 ]
Bora, Urvi [1 ]
机构
[1] MIT World Peace Univ, Sch Mech Engn, Dr Vishwanath Karad, Pune, India
关键词
Dental implants; Mathematical model; Micro; -displacement; Frequency Response Analysis; Vibration; IN-VIVO; STABILITY; VIBRATION; INTERFACE; STRESS; TOOTH; OSSEOINTEGRATION; DESIGN; DEVICE;
D O I
10.1016/j.jmbbm.2023.105735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this paper is to formulate a mathematical model of dental prosthetic using single degree of freedom (SDOF) to assess the micro-displacement under electromagnetic excitation. Using Finite Element Analysis (FEA) and values from literature, stiffness and damping values of the mathematical model were estimated. For ensuring the successful implantation of dental implant system, monitoring of primary stability in terms of micro -displacement is crucial. One of the most popular techniques for the measurement of stability is the Frequency Response Analysis (FRA). This technique assesses the resonant frequency of vibration corresponding to the maximum micro-displacement (micro-mobility) of the implant. Among the different FRA techniques, the most common method is the Electromagnetic FRA. The subsequent displacement of the implant in the bone is esti-mated by equations of vibration. A comparison has been made to observe the variation in resonance frequency and micro-displacement due to varying input frequency ranges of 1-40 Hz. The micro-displacement and cor-responding resonance frequency were plotted using MATLAB and the variation in resonance frequency is found to be negligible. The present mathematical model is a preliminary approach to understand the variation of micro -displacement with reference to electromagnetic excitation force and to obtain the resonance frequency. The present study validated the use of input frequency ranges (1-30 Hz) with negligible variation in micro -displacement and corresponding resonance frequency. However, input frequency ranges beyond 31-40 Hz is not recommended due to large variation in micromotion and corresponding resonance frequency.
引用
收藏
页数:8
相关论文
共 47 条
[1]   A simple mathematical model for the resonance frequency analysis of dental implant stability: Implant clamping quotient [J].
Argatov, Ivan ;
Iantchenko, Alexei .
MECHANICS RESEARCH COMMUNICATIONS, 2019, 95 :67-70
[2]  
Bin, 2008, APPL PHYS B-LASERS O, V8, P1
[3]   Assessment of dental implant stability by means of the electromechanical impedance method [J].
Boemio, Giovanni ;
Rizzo, Piervincenzo ;
De Nardo, Luigi .
SMART MATERIALS AND STRUCTURES, 2011, 20 (04)
[4]   Initial Stability Measurements of Implants Using a New Magnetic Resonance Frequency Analyzer With Titanium Transducers: An Ex Vivo Study [J].
Bural, Canan ;
Dayan, Cagatay ;
Geckili, Onur .
JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (01) :35-40
[5]   The design of a vibration transducer to monitor the integrity of dental implants [J].
Cawley, P ;
Pavlakovic, B ;
Alleyne, DN ;
George, R ;
Back, T ;
Meredith, N .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1998, 212 (H4) :265-272
[6]   Mathematical equations for dental implant stability patterns during the osseointegration period, based on previous resonance frequency analysis studies [J].
Charatchaiwanna, Attakorn ;
Rojsiraphisa, Thaned ;
Aunmeungtong, Weerapan ;
Reichart, Peter A. ;
Khongkhunthian, Pathawee .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) :1028-1040
[7]  
Chu TG, 2016, INT J DENT ORAL SCI, V3, P358, DOI DOI 10.19070/2377-8075-1600073
[8]   Effects of pulsed electromagnetic field vibration on tooth movement induced by magnetic and mechanical forces: a preliminary study [J].
Darendeliler, M. Ali ;
Zea, A. ;
Shen, G. ;
Zoellner, H. .
AUSTRALIAN DENTAL JOURNAL, 2007, 52 (04) :282-287
[9]   ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency [J].
Debruyne, Stijn ;
Grognard, Nicolas ;
Verleye, Gino ;
Van Massenhove, Korneel ;
Mavreas, Dimitrios ;
Vande Vannet, Bart .
INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2017, 3
[10]   Mathematical modeling of resonant linear vibratory conveyor with electromagnetic excitation: simulations and experimental results [J].
Despotovic, Zeljko V. ;
Urukalo, Djordje ;
Lecic, Milan R. ;
Cosic, Aleksandar .
APPLIED MATHEMATICAL MODELLING, 2017, 41 :1-24