Full-field strain mapping of healthy and pathological mouse aortas using stereo digital image correlation

被引:4
|
作者
Lane, Brooks A. [1 ]
Cardoza, Ricardo J. [2 ]
Lessner, Susan M. [1 ,3 ]
Vyavahare, Narendra R. [4 ]
Sutton, Michael A. [5 ]
Eberth, John F. [6 ,7 ]
机构
[1] Univ South Carolina, Biomed Engn, Columbia, SC USA
[2] Univ Pittsburgh, Mech Engn & Mat Sci, Pittsburgh, PA USA
[3] Univ South Carolina, Cell Biol & Anat, Columbia, SC USA
[4] Clemson Univ, Biomed Engn, Clemson, SC USA
[5] Univ South Carolina, Mech Engn, Columbia, SC USA
[6] Drexel Univ, Biomed Engn, Sci & Hlth Syst, Philadelphia, PA USA
[7] 3141 Chestnut St, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Stereo imaging; DIC; Mouse aortopathy; Arterial biomechanics; Strain map; CAROTID ARTERIES; MODELS; MECHANICS; EVOLUTION;
D O I
10.1016/j.jmbbm.2023.105745
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The murine aorta is a complex, heterogeneous structure that undergoes large and sometimes asymmetrical deformations under loading. For analytical convenience, mechanical behavior is predominantly described using global quantities that fail to capture critical local information essential to elucidating aortopathic processes. Here, in our methodological study, we used stereo digital image correlation (StereoDIC) to measure the strain profiles of speckle-patterned healthy and elastase-infused, pathological mouse aortas submerged in a temperature-controlled liquid medium. Our unique device rotates two 15-degree stereo-angle cameras that gather sequential digital images while simultaneously performing conventional biaxial pressure-diameter and force-length testing. A StereoDIC Variable Ray Origin (VRO) camera system model is employed to correct for high-magnification image refraction through hydrating physiological media. The resultant Green-Lagrange surface strain tensor was quantified at different blood vessel inflation pressures, axial extension ratios, and after aneurysm-initiating elastase exposure. Quantified results capture large, heterogeneous, inflation-related, circumferential strains that are drastically reduced in elastase-infused tissues. Shear strains, however, were very small on the tissue's surface. Spatially averaged StereoDIC-based strains were generally more detailed than those determined using conventional edge detection techniques.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] 3D Full-Field Deformation Measuring Technique Using Digital Image Correlation
    Nadarajah, Sujeeka
    Arulkumar, Vithushanthini
    Mallikarachchi, Chinthaka
    MERCON 2020: 6TH INTERNATIONAL MULTIDISCIPLINARY MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON), 2020, : 1 - 6
  • [42] Full-field Measurement at the Weave Scale in Hemp/Epoxy Composite Using Digital Image Correlation
    Perrier, Amelie
    de Vasconcellos, Davi S.
    Touchard, Fabienne
    Chocinski-Arnault, Laurence
    Mellier, David
    POLYMERS & POLYMER COMPOSITES, 2015, 23 (09): : 589 - 599
  • [43] Full-field measurements of heterogeneous deformation patterns on polymeric foams using digital image correlation
    Wang, Y
    Cuitiño, AM
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2002, 39 (13-14) : 3777 - 3796
  • [44] Full-field deformation measurement of a large-rotation object using digital image correlation
    Wang, Lianpo
    Gu, Yonggang
    Zhai, Chao
    AOS AUSTRALIAN CONFERENCE ON OPTICAL FIBRE TECHNOLOGY (ACOFT) AND AUSTRALIAN CONFERENCE ON OPTICS, LASERS, AND SPECTROSCOPY (ACOLS) 2019, 2019, 11200
  • [45] Full-field strain distribution in multi-vertebra spine segments: An in vitro application of digital image correlation
    Palanca, Marco
    Marco, Miguel
    Ruspi, Maria Luisa
    Cristofolini, Luca
    MEDICAL ENGINEERING & PHYSICS, 2018, 52 : 76 - 83
  • [46] A Global Digital Image Correlation Enhanced Full-Field Bulge Test Method
    Neggers, J.
    Hoefnagels, J. P. M.
    Hild, F.
    Roux, S.
    Geers, M. G. D.
    IUTAM SYMPOSIUM ON FULL-FIELD MEASUREMENTS AND IDENTIFICATION IN SOLID MECHANICS, 2011, 2012, 4 : 73 - 81
  • [47] Digital Image Correlation for Full-Field High Resolution Assessment of Leaf Growth
    Campo, Adriaan
    Klosiewicz, Przemyslaw
    Dirckx, Joris
    JOURNAL OF PLANT GROWTH REGULATION, 2015, 34 (02) : 433 - 439
  • [48] Full-Field Settlement Measurement at Fresh Cementitious Material by Digital Image Correlation
    Dzaye, Evin Dildar
    Tsangouri, Eleni
    De Schutter, Geert
    Aggelis, Dimitrios G.
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2019, 17 (04) : 168 - 176
  • [49] Full-field measurements with Digital Image Correlation for vibro-impact characterisation
    Chabrier, R.
    Sadoulet-Reboul, E.
    Chevallier, G.
    Foltete, E.
    Jeannin, T.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 156