Full-field strain mapping of healthy and pathological mouse aortas using stereo digital image correlation

被引:4
|
作者
Lane, Brooks A. [1 ]
Cardoza, Ricardo J. [2 ]
Lessner, Susan M. [1 ,3 ]
Vyavahare, Narendra R. [4 ]
Sutton, Michael A. [5 ]
Eberth, John F. [6 ,7 ]
机构
[1] Univ South Carolina, Biomed Engn, Columbia, SC USA
[2] Univ Pittsburgh, Mech Engn & Mat Sci, Pittsburgh, PA USA
[3] Univ South Carolina, Cell Biol & Anat, Columbia, SC USA
[4] Clemson Univ, Biomed Engn, Clemson, SC USA
[5] Univ South Carolina, Mech Engn, Columbia, SC USA
[6] Drexel Univ, Biomed Engn, Sci & Hlth Syst, Philadelphia, PA USA
[7] 3141 Chestnut St, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Stereo imaging; DIC; Mouse aortopathy; Arterial biomechanics; Strain map; CAROTID ARTERIES; MODELS; MECHANICS; EVOLUTION;
D O I
10.1016/j.jmbbm.2023.105745
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The murine aorta is a complex, heterogeneous structure that undergoes large and sometimes asymmetrical deformations under loading. For analytical convenience, mechanical behavior is predominantly described using global quantities that fail to capture critical local information essential to elucidating aortopathic processes. Here, in our methodological study, we used stereo digital image correlation (StereoDIC) to measure the strain profiles of speckle-patterned healthy and elastase-infused, pathological mouse aortas submerged in a temperature-controlled liquid medium. Our unique device rotates two 15-degree stereo-angle cameras that gather sequential digital images while simultaneously performing conventional biaxial pressure-diameter and force-length testing. A StereoDIC Variable Ray Origin (VRO) camera system model is employed to correct for high-magnification image refraction through hydrating physiological media. The resultant Green-Lagrange surface strain tensor was quantified at different blood vessel inflation pressures, axial extension ratios, and after aneurysm-initiating elastase exposure. Quantified results capture large, heterogeneous, inflation-related, circumferential strains that are drastically reduced in elastase-infused tissues. Shear strains, however, were very small on the tissue's surface. Spatially averaged StereoDIC-based strains were generally more detailed than those determined using conventional edge detection techniques.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Improved Newton-Raphson digital image correlation method for full-field displacement and strain calculation
    Cofaru, Corneliu
    Philips, Wilfried
    Van Paepegem, Wim
    APPLIED OPTICS, 2010, 49 (33) : 6472 - 6484
  • [32] Full-Field Strain Behavior Of Friction Stir-Welded Titanium Alloy By Digital Image Correlation
    Ramulu, Mamidala, 1600, Trans Tech Publications Ltd (692):
  • [33] High temperature full-field strain measurement based on digital image correlation during arc welding
    Zhou, X.
    Chen, H. B.
    Chen, J.
    Chen, S. B.
    Feng, Zhili
    2016 IEEE WORKSHOP ON ADVANCED ROBOTICS AND ITS SOCIAL IMPACTS (ARSO), 2016, : 203 - 207
  • [34] Application of digital image correlation to full-field measurement of shrinkage strain of dental composites附视频
    Jian-ying LI
    Andrew LAU
    Alex S. L. FOK
    Journal of Zhejiang University-Science A(Applied Physics & Engineering), 2013, (01) : 1 - 10
  • [35] Full-field measurement of rotating blades based on digital image correlation
    Ye M.
    Liang J.
    Qian B.
    Zong Y.
    Gong C.
    Liang, Jin (liangjin@mail.xjtu.edu.cn), 1757, Central South University of Technology (51): : 1757 - 1766
  • [36] TECHNICAL SPOTLIGHT Using Digital Image Correlation to Measure Full Field Strain
    Bailey, Daniel
    ADVANCED MATERIALS & PROCESSES, 2014, 172 (10): : 23 - 24
  • [37] Single-camera high-speed stereo-digital image correlation for full-field vibration measurement
    Yu, Liping
    Pan, Bing
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2017, 94 : 374 - 383
  • [38] Application of Stereo-Digital Image Correlation to Full-Field 3-D Deformation Measurement of Intervertebral Disc
    Spera, D.
    Genovese, K.
    Voloshin, A.
    STRAIN, 2011, 47 : E572 - E587
  • [39] Full-field strain mapping by optical correlation of micrographs acquired during deformation
    Da Fonseca, JQ
    Mummery, PM
    Withers, PJ
    JOURNAL OF MICROSCOPY, 2005, 218 : 9 - 21
  • [40] Full-field shear analyses of sandwich core materials using Digital Image Correlation (DIC)
    Fathi, Amir
    Keller, Jan-Hendrik
    Altstaedt, Volker
    COMPOSITES PART B-ENGINEERING, 2015, 70 : 156 - 166