3D Ultrasound Mosaic of the Whole Shoulder: A Feasibility Study

被引:0
作者
Sewify, Ahmed [1 ,2 ]
Antico, Maria [1 ,3 ]
Steffens, Marian [1 ]
Roots, Jacqueline [1 ,2 ]
Gupta, Ashish [4 ,5 ]
Cutbush, Kenneth [4 ,6 ]
Pivonka, Peter [2 ,4 ,7 ]
Fontanarosa, Davide [1 ,2 ]
机构
[1] Queensland Univ Technol, Sch Clin Sci, 2 George St, Brisbane, Qld 4000, Australia
[2] Queensland Univ Technol, Ctr Biomed Technol CBT, 2 George St, Brisbane, Qld 4000, Australia
[3] Commonwealth Sci & Ind Res Org CSIRO, Australian eHlth Res Ctr, 296 Herston Rd, Brisbane, Qld 4029, Australia
[4] Queensland Univ Technol, Queensland Unit Adv Shoulder Res QUASR, 2 George St, Brisbane, Qld 4000, Australia
[5] Greenslopes Private Hosp, Newdegate St, Greenslopes, Qld 4120, Australia
[6] Univ Queensland, Sch Med, St Lucia, Qld 4072, Australia
[7] Queensland Univ Technol, Fac Engn, Sch Mech Med & Proc Engn, 2 George St, Brisbane, Qld 4000, Australia
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 05期
关键词
ultrasound shoulder mosaic; ultrasound shoulder atlas; shoulder tomography; 3D ultrasound panorama; machine learning; 3D image registration; 3D image stitching; volumetric reconstruction; REGISTRATION; CT;
D O I
10.3390/app14052152
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A protocol is proposed to acquire a tomographic ultrasound (US) scan of the musculoskeletal (MSK) anatomy in the rotator cuff region. Current clinical US imaging techniques are hindered by occlusions and a narrow field of view and require expert acquisition and interpretation. There is limited literature on 3D US image registration of the shoulder or volumetric reconstruction of the full shoulder complex. We believe that a clinically accurate US volume reconstruction of the entire shoulder can aid in pre-operative surgical planning and reduce the complexity of US interpretation. The protocol was used in generating data for deep learning model training to automatically register US mosaics in real-time. An in vivo 3D US tomographic reconstruction of the entire rotator cuff region was produced by registering 53 sequential 3D US volumes acquired by an MSK sonographer. Anatomical surface thicknesses and distances in the US mosaic were compared to their corresponding MRI measurements as the ground truth. The humeral head surface was marginally thicker in the reconstructed US mosaic than its original thickness observed in a single US volume by 0.65 mm. The humeral head diameter and acromiohumeral distance (ACHD) matched with their measured MRI distances with a reconstruction error of 0 mm and 1.2 mm, respectively. Furthermore, the demonstration of 20 relevant MSK structures was independently graded between 1 and 5 by two sonographers, with higher grades indicating poorer demonstration. The average demonstration grade for each anatomy was as follows: bones = 2, muscles = 3, tendons = 3, ligaments = 4-5 and labrum = 4-5. There was a substantial agreement between sonographers (Cohen's Weighted kappa of 0.71) on the demonstration of the structures, and they both independently deemed the mosaic clinically acceptable for the visualisation of the bony anatomy. Ligaments and the labrum were poorly observed due to anatomy size, location and inaccessibility in a static scan, and artefact build-up from the registration and compounding approaches.
引用
收藏
页数:21
相关论文
共 35 条
  • [1] 4D Ultrasound-Based Knee Joint Atlas for Robotic Knee Arthroscopy: A Feasibility Study
    Antico, Maria
    Sasazawa, Fumio
    Takeda, Yu
    Jaiprakash, Anjali T.
    Wille, Marie-Luise
    Pandey, Ajay K.
    Crawford, Ross
    Fontanarosa, Davide
    [J]. IEEE ACCESS, 2020, 8 : 146331 - 146341
  • [2] Beggs I., 2017, Eur. Soc. Musculoskelet. Radiol, V1, P1
  • [3] Machine learning for medical ultrasound: status, methods, and future opportunities
    Brattain, Laura J.
    Telfer, Brian A.
    Dhyani, Manish
    Grajo, Joseph R.
    Samir, Anthony E.
    [J]. ABDOMINAL RADIOLOGY, 2018, 43 (04) : 786 - 799
  • [4] Bone registration with 3D CT and ultrasound data sets
    Brendel, B
    Winter, S
    Rick, A
    Stockheim, M
    Ermert, H
    [J]. CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 426 - 432
  • [5] Bushberg J.T., 2002, The Essential Physics of Medical Imaging, V2, P933
  • [6] Ultrasound registration: A review
    Che, Chengqian
    Mathai, Tejas Sudharshan
    Galeotti, John
    [J]. METHODS, 2017, 115 : 128 - 143
  • [7] Cheng Yao, 2009, Proceedings of the SPIE - The International Society for Optical Engineering, V7265, DOI 10.1117/12.810906
  • [8] Duric N., 2018, Breast Imaging, DOI 10.5772/intechopen.69794
  • [9] Work-Related Musculoskeletal Disorders (WRMSD) Among Registered Diagnostic Medical Sonographers and Vascular Technologists A Representative Sample
    Evans, Kevin
    Roll, Shawn
    Baker, Joan
    [J]. JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2009, 25 (06) : 287 - 299
  • [10] Farina R., 2012, Errors in Radiology, P79