Predictive Utility of Near-Infrared Spectroscopy for the Outcomes of Hypoxic-Ischemic Encephalopathy: A Systematic Review and Meta-Analysis

被引:1
作者
El-Atawi, Khaled M. [1 ]
Osman, Mohammed F. [2 ]
Hassan, Moustafa [3 ]
Siwji, Zohra A. [2 ]
Hassan, Ahmed A. [4 ]
Abed, Maysam Y. [5 ]
Elsayed, Yasser [6 ]
机构
[1] Latifa Women & Children Hosp, Neonatal Intens Care Unit, Pediat, Dubai, U Arab Emirates
[2] Tawam Hosp, Neonatol, Al Ain, Yemen
[3] Dubai Hosp, Neonatol, Dubai, U Arab Emirates
[4] Al Jalila Childrens Special Hosp, Pediat Cardiol, Dubai, U Arab Emirates
[5] Ibn Albitar Tertiary Ctr Cardiol, Pediat Cardiol, Baghdad, Iraq
[6] Univ Manitoba, Max Rady Coll Med, Hlth Sci Ctr Winnipeg, Pediat & Neonatol, Winnipeg, MB, Canada
关键词
meta-analysis; systematic review; perinatal outcomes; hypoxic-ischemic encephalopathy; near-infrared spectroscopy; AMPLITUDE-INTEGRATED ELECTROENCEPHALOGRAPHY; OXYGEN-SATURATION; HYPOTHERMIA; ASPHYXIA; INFANTS; INDEX;
D O I
10.7759/cureus.51162
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This systematic review and meta-analysis aimed to assess the utility of near-infrared spectroscopy (NIRS) in predicting the perinatal outcomes of neonates with hypoxic-ischemic encephalopathy (HIE). We conducted a literature search on Medline via PubMed, Web of Science, Scopus, and CENTRAL Library. We included studies that utilized early NIRS monitoring to study the accuracy of NIRS in predicting the perinatal outcomes of neonates with hypoxic-ischemic encephalopathy. Nine studies that met our eligibility criteria were included. These studies were published between 2012 and 2023. In this meta-analysis, no significant differences in regional cerebral oxygen saturation (cSpO2) were found between normal and abnormal groups at 12 hours (MD = 0.21, 95% CI: -6.39 to 6.82, P = 0.95) and 24 hours (MD = -1.96, 95% CI: -6.95 to 3.03, P = 0.44). However, at 48 hours, cSpO2 was significantly lower in the normal group (MD = -4.9, 95% CI: -5.91 to 3.89, P < 0.00001). At 72 hours, our analysis revealed a significant difference with lower cSpO2 in the normal group (MD = -3.0, 95% CI: -5.5 to -0.5, P = 0.02). Regarding cerebral fractional tissue oxygen extraction (FTOE), no significant differences were observed at 12 hours (MD = 0.03, 95% CI: -0.02 to 0.09, P = 0.24). After 24 hours, the normal group exhibited lower FTOE (MD = -0.03, 95% CI: -0.04 to -0.01, P < 0.001), while after 48 hours, the normal group had higher FTOE (MD = 0.07, 95% CI: 0.04 to 0.10, P < 0.0001). Early cerebral NIRS monitoring is beneficial in predicting the outcomes of HIE in term neonates. Our analysis showed that several NIRS parameters, such as regional cSpO2 and cerebral FTOE, are significantly associated with adverse outcomes in the first 72 hours of birth.
引用
收藏
页数:10
相关论文
共 29 条
[1]   Early predictors of short term neurodevelopmental outcome in asphyxiated cooled infants. A combined brain amplitude integrated electroencephalography and near infrared spectroscopy study [J].
Ancora, Gina ;
Maranella, Eugenia ;
Grandi, Sara ;
Sbravati, Francesca ;
Coccolini, Elena ;
Savini, Silvia ;
Faldella, Giacomo .
BRAIN & DEVELOPMENT, 2013, 35 (01) :26-31
[2]   Reference Ranges for Cerebral Tissue Oxygen Saturation Index in Term Neonates during Immediate Neonatal Transition after Birth [J].
Baik, Nariae ;
Urlesberger, Berndt ;
Schwaberger, Bernhard ;
Schmoelzer, Georg M. ;
Mileder, Lukas ;
Avian, Alexander ;
Pichler, Gerhard .
NEONATOLOGY, 2015, 108 (04) :283-286
[3]   Monitoring Cerebral Oxygenation in Neonates: An Update [J].
Dix, Laura Marie Louise ;
van Bel, Frank ;
Lemmers, Petra Maria Anna .
FRONTIERS IN PEDIATRICS, 2017, 5
[4]   Clinical, biological and electroencephalographic monitoring of newborns with neurological risk in the Neonatal Intensive Care Unit [J].
Doandes, Florina Marinela ;
Manea, Aniko-Maria ;
Lungu, Nicoleta ;
Cioboata, Daniela ;
Brandibur, Timea ;
Costescu, Oana ;
Hudisteanu, Anca ;
Boia, Eugen Radu ;
Boia, Marioara .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2021, 22 (01)
[5]   Hypoxic-Ischemic Encephalopathy A Review for the Clinician [J].
Douglas-Escobar, Martha ;
Weiss, Michael D. .
JAMA PEDIATRICS, 2015, 169 (04) :397-403
[6]   Role of Near-Infrared Spectroscopy in Monitoring the Clinical Course of Asphyxiated Neonates Treated with Hypothermia [J].
Farag, Marwa Mohamed ;
Khedr, Ahmed Abd El-Halim Abd El-Raziq ;
Attia, MennattAllah Hassan ;
Ghazal, Hesham Abd EL-Rahim .
AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 (04) :429-438
[7]   Cerebro-splanchnic oxygenation ratio (CSOR) using near infrared spectroscopy may be able to predict splanchnic ischaemia in neonates [J].
Fortune, PM ;
Wagstaff, M ;
Petros, AJ .
INTENSIVE CARE MEDICINE, 2001, 27 (08) :1401-1407
[8]   Prediction of Outcome in Neonates with Hypoxic-Ischemic Encephalopathy II: Role of Amplitude-Integrated Electroencephalography and Cerebral Oxygen Saturation Measured by Near-Infrared Spectroscopy [J].
Goeral, Katharina ;
Urlesberger, Berndt ;
Giordano, Vito ;
Kasprian, Gregor ;
Wagner, Michael ;
Schmidt, Lisa ;
Berger, Angelika ;
Klebermass-Schrehof, Katrin ;
Olischar, Monika .
NEONATOLOGY, 2017, 112 (03) :193-202
[9]   Pathophysiology of hypoxic-ischemic encephalopathy: a review of the past and a view on the future [J].
Greco, P. ;
Nencini, G. ;
Piva, I. ;
Scioscia, M. ;
Volta, C. A. ;
Spadaro, S. ;
Neri, M. ;
Bonaccorsi, G. ;
Greco, F. ;
Cocco, I. ;
Sorrentino, F. ;
D'Antonio, F. ;
Nappi, L. .
ACTA NEUROLOGICA BELGICA, 2020, 120 (02) :277-288
[10]   Use of amplitude-integrated electroencephalography (aEEG) and near infrared spectroscopy findings in neonates with asphyxia during selective head cooling [J].
Gucuyener, Kivilcim ;
Beken, Serdar ;
Ergenekon, Ebru ;
Soysal, Sebnem ;
Hirfanoglu, Ibrahim ;
Turan, Ozden ;
Unal, Sezin ;
Altuntas, Nilgun ;
Kazanci, Ebru ;
Kulali, Ferit ;
Koc, Esin ;
Turkyilmaz, Canan ;
Onal, Esra ;
Atalay, Yildiz .
BRAIN & DEVELOPMENT, 2012, 34 (04) :280-286