Mass Spectrometry Imaging of Biomaterials

被引:1
作者
Kret, Paulina [1 ]
Bodzon-Kulakowska, Anna [1 ]
Drabik, Anna [1 ]
Ner-Kluza, Joanna [1 ]
Suder, Piotr [1 ]
Smoluch, Marek [1 ]
机构
[1] AGH Univ Krakow, Fac Mat Sci & Ceram, Dept Analyt Chem & Biochem, A Mickiewicza 30, PL-30059 Krakow, Poland
关键词
mass spectrometry imaging; MSI; SIMS; MALDI; DESI; biomaterials; DESORPTION ELECTROSPRAY-IONIZATION; EVEROLIMUS-ELUTING STENTS; TOF-SIMS; SURFACE-ANALYSIS; IN-VIVO; POLYMERIC IMPLANTS; CELL ATTACHMENT; BONE; TISSUE; DESORPTION/IONIZATION;
D O I
10.3390/ma16186343
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The science related to biomaterials and tissue engineering accounts for a growing part of our knowledge. Surface modifications of biomaterials, their performance in vitro, and the interaction between them and surrounding tissues are gaining more and more attention. It is because we are interested in finding sophisticated materials that help us to treat or mitigate different disorders. Therefore, efficient methods for surface analysis are needed. Several methods are routinely applied to characterize the physical and chemical properties of the biomaterial surface. Mass Spectrometry Imaging (MSI) techniques are able to measure the information about molecular composition simultaneously from biomaterial and adjacent tissue. That is why it can answer the questions connected with biomaterial characteristics and their biological influence. Moreover, this kind of analysis does not demand any antibodies or dyes that may influence the studied items. It means that we can correlate surface chemistry with a biological response without any modification that could distort the image. In our review, we presented examples of biomaterials analyzed by MSI techniques to indicate the utility of SIMS, MALDI, and DESI-three major ones in the field of biomaterials applications. Examples include biomaterials used to treat vascular system diseases, bone implants with the effects of implanted material on adjacent tissues, nanofibers and membranes monitored by mass spectrometry-related techniques, analyses of drug-eluting long-acting parenteral (LAPs) implants and microspheres where MSI serves as a quality control system.
引用
收藏
页数:29
相关论文
共 113 条
[91]   Biomimetic materials for tissue engineering [J].
Shin, H ;
Jo, S ;
Mikos, AG .
BIOMATERIALS, 2003, 24 (24) :4353-4364
[92]   Reversible polymers formed from self-complementary monomers using quadruple hydrogen bonding [J].
Sijbesma, RP ;
Beijer, FH ;
Brunsveld, L ;
Folmer, BJB ;
Hirschberg, JHKK ;
Lange, RFM ;
Lowe, JKL ;
Meijer, EW .
SCIENCE, 1997, 278 (5343) :1601-1604
[93]   Surface study of collagen/poloxamine hydrogels by a 'deep freezing' ToF-SIMS approach [J].
Sosnik, A ;
Sodhi, RNS ;
Brodersen, PM ;
Sefton, MV .
BIOMATERIALS, 2006, 27 (11) :2340-2348
[94]  
Sridharan Gokul, 2012, J Oral Maxillofac Pathol, V16, P251, DOI 10.4103/0973-029X.99081
[95]   Polypyrrole doped with 2 peptide sequences from laminin [J].
Stauffer, WR ;
Cui, XT .
BIOMATERIALS, 2006, 27 (11) :2405-2413
[96]   Molecular Imaging of Biological Samples on Nanophotonic Laser Desorption Ionization Platforms [J].
Stopka, Sylwia A. ;
Rong, Charles ;
Korte, Andrew R. ;
Yadavilli, Sridevi ;
Nazarian, Javad ;
Razunguzwa, Trust T. ;
Morris, Nicholas J. ;
Vertes, Akos .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (14) :4482-4486
[97]   Submicron 3,4-dihydroxybenzoic acid-TiO2 composite particles for enhanced MALDI MS imaging of secondary metabolites in the root of differently aged baical skullcap [J].
Sun, Ruiyang ;
Zhang, Ying ;
Tang, Weiwei ;
Li, Bin .
ANALYST, 2022, 147 (13) :3017-3024
[98]  
Suni Anton O, 2023, Biomater Investig Dent, V10, P2209593, DOI 10.1080/26415275.2023.2209593
[99]   Mass spectrometry sampling under ambient conditions with desorption electrospray ionization [J].
Takáts, Z ;
Wiseman, JM ;
Gologan, B ;
Cooks, RG .
SCIENCE, 2004, 306 (5695) :471-473
[100]  
Tanrikulu IC, 2016, NAT CHEM, V8, P1008, DOI [10.1038/NCHEM.2556, 10.1038/nchem.2556]