Developing non-enzymatic approach for ultrasensitive detection of dopamine using electrospun Co3O4/SiO2 nanofibers

被引:7
|
作者
Qamar, Zahid [1 ]
Gul, Raja Fazan [2 ]
Gurmani, Samia Faiz [3 ]
Akhtar, Javeed [4 ]
Atif, Muhammad [1 ]
Khalid, Waqas [1 ]
机构
[1] Air Univ, Dept Phys, Funct Mat Lab, Smart Surfaces & Mat Grp, PAF Complex, Islamabad, Pakistan
[2] X Celeprint Ltd, Cork, Ireland
[3] Natl Ctr Phys, Ctr Earthquake Studies, Islamabad, Pakistan
[4] Mirpur Univ Sci & Technol, Dept Chem, Funct Nanomat Lab, Mirpur, Kashmir, Pakistan
关键词
SiO2; nanofibers; Dopamine; Electrochemical detection; SIMULTANEOUS ELECTROCHEMICAL DETECTION; ASCORBIC-ACID; GRAPHENE OXIDE; SENSOR; NANOCOMPOSITE; FABRICATION; COMPOSITE;
D O I
10.1016/j.ceramint.2023.03.166
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Several neurological illnesses, such as schizophrenia, Parkinson's disease, and depression, involve abnormalities in the neurotransmitter dopamine (DA). Therefore, for the early diagnosis of diseases linked with aberrant phases, very sensitive detection technologies are needed. Here, a report is given on a new platform for the ac-curate electrochemical detection of DA using a cobalt oxide (Co3O4) and silica (SiO2) nanofiber-modified gold (Au) electrode. SiO2 and 10% Co3O4-90% SiO2 (Co3O4/SiO2) nanofibers were created by electrospinning. The structural and morphological characteristics of SiO2 and Co3O4/SiO2 were examined using X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDX). Using cyclic voltammetry (CV) and differential pulse voltammetry (DPV), the electrochemical response of DA was analyzed in relevant biological electrolytes like phosphate-buffered saline (PBS) at pH 7.2. Co3O4/SiO2 being investigated as a highly effective electrode material for electrochemical detection of DA revealed that these electrode materials can achieve low overpotentials for DA oxidation. DA displayed the detection and sensitivity limits of 6.7 fM and 22.30 fM, respectively, throughout a linear response of 1 pM-1 mM, while Au modified with Co3O4/SiO2 nanofibers showed the most promising performance with good stability throughout a variety of scan rates (5-100 mV/s). The developed sensor's analytical performance has shown that it is capable of quantifying DA in aqueous media.
引用
收藏
页码:20381 / 20387
页数:7
相关论文
共 50 条
  • [41] Fabrication of NiMn2O4 nanosheets on reduced graphene oxide for non-enzymatic detection of glucose
    Dong, Min
    Hu, Hongli
    Ding, Shujiang
    Wang, Changcheng
    Li, Long
    MATERIALS TECHNOLOGY, 2021, 36 (04) : 203 - 211
  • [42] Synthesis of Co3O4 nanostructures using a solvothermal approach
    Sun, Lingna
    Li, Huifeng
    Ren, Ling
    Hu, Changwen
    SOLID STATE SCIENCES, 2009, 11 (01) : 108 - 112
  • [43] Co3O4 based non-enzymatic glucose sensor with high sensitivity and reliable stability derived from hollow hierarchical architecture
    Tian, Liangliang
    He, Gege
    Cai, Yanhua
    Wu, Shenping
    Su, Yongyao
    Yan, Hengqing
    Yang, Cong
    Chen, Yanling
    Li, Lu
    NANOTECHNOLOGY, 2018, 29 (07)
  • [44] Construction of Co3O4/SnO2 yolk-shell nanofibers for acetone gas detection
    Wang, Wanjing
    Xian, Jianbiao
    Li, Jin
    Yu, Mengfang
    Duan, Qiutian
    Leung, Chung Ming
    Zeng, Min
    Gao, Xingsen
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 398
  • [45] Non-enzymatic photoelectrochemical sensors based on Schiff base and chitosan co-decorated TiO2 nanosheets for dopamine detection
    Shang, Xing
    Weng, Qinghua
    Wang, Fei
    Wang, Jiaye
    Huang, Siqi
    Chen, Shuyu
    Han, Zhizhong
    Chen, Jinghua
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2021, 418
  • [46] Nonenzymatic amperometric dopamine sensor based on a carbon ceramic electrode of type SiO2/C modified with Co3O4 nanoparticles
    Abdur Rehman Younus
    Jibran Iqbal
    Nawshad Muhammad
    Fozia Rehman
    Muhammad Tariq
    Abdul Niaz
    Syed Badshah
    Tawfik A. Saleh
    Abdur Rahim
    Microchimica Acta, 2019, 186
  • [47] Electrochemical non-enzymatic glucose sensors based on nano-composite of Co3O4 and multiwalled carbon nanotube
    Xiaoyun Lin
    Yanfang Wang
    Miaomiao Zou
    Tianxiang Lan
    Yongnian Ni
    Chinese Chemical Letters, 2019, 30 (06) : 1157 - 1160
  • [48] Electrochemical non-enzymatic glucose sensors based on nano-composite of Co3O4 and multiwalled carbon nanotube
    Lin, Xiaoyun
    Wang, Yanfang
    Zou, Miaomiao
    Lan, Tianxiang
    Ni, Yongnian
    CHINESE CHEMICAL LETTERS, 2019, 30 (06) : 1157 - 1160
  • [49] Nickel-Foam-Supported Co3O4 Nanosheets/PPy Nanowire Heterostructure for Non-enzymatic Glucose Sensing
    Dai, Hongxiu
    Lin, Meng
    Wang, Nan
    Xu, Fei
    Wang, Donglei
    Ma, Houyi
    CHEMELECTROCHEM, 2017, 4 (05): : 1135 - 1140
  • [50] Probing the crystal plane effect of Co3O4 for non-enzymatic electrochemistry sensing performance toward hydrogen peroxide
    Jiang, Jiaojiao
    Zhang, Zhixuan
    Liang, Zhiqi
    Chen, Wenying
    Zhong, Manfei
    Xu, Kai
    Wu, Zhouling
    APPLIED SURFACE SCIENCE, 2023, 639