A portable microfluidic electrochemical sensing platform for rapid detection of hazardous metal Pb2+based on thermocapillary convection using 3D Ag-rGO-f-Ni(OH)2/NF as a signal amplifying element

被引:21
作者
Ma, Shangshang [1 ,2 ]
Zhao, Wei [1 ]
Zhang, Qing [2 ]
Zhang, Keying [2 ]
Liang, Chong [1 ]
Wang, Dingkai [1 ]
Liu, Xutang [1 ]
Zhan, Xijie [2 ]
机构
[1] China Univ Min & Technol, Sch Chem Engn &Technol, Xuzhou 221100, Peoples R China
[2] Suzhou Univ, Anhui Higher Educ Inst, Sch Chem & Chem Engn, Key Lab Spin Electron & Nanomat, Suzhou 234000, Peoples R China
关键词
Microfluidic chip; Thermocapillary convection; 3DAg-rGO-f-Ni(OH)2; NF; RapidPb2+detection; Point-of-care testing; COMPOSITE FILM; NICKEL FOAM; NI FOAM; GRAPHENE; NANOPARTICLES; ELECTRODES; OXALATE; SYSTEM; DEVICE;
D O I
10.1016/j.jhazmat.2023.130923
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Heavy metal pollution is causing a great threat to ecological environment and public health, which needs an efficient strategy for monitoring. A portable microfluidic electrochemical sensing system was developed for the determination of heavy metal ions. Herein, the detection of Pb2+ was chosen as a model, and a microfluidic electrochemical sensing chip relying on a smartphone-based electrochemical workstation was proposed for rapid detection Pb2+ with the assistance of thermocapillary convection result from the formed temperature gradient. The 3D Ag-rGO-f-Ni(OH)2/NF composites, prepared by one-step hydrothermal method without any Ni precursor salt, were used to further amplify electrochemical signals under the synergistic effect of thermocapillary con-vection. The thermocapillary convection could accelerate the preconcentration process and shorten the detection time (save 300 s of preconcentration time). The fabricated system exhibited the exceptional competence for monitoring of Pb2+ range from 0.01 mu g/L to 2100 mu g/L with a low detection limit (LOD) of 0.00464 mu g/L. Furthermore, this portable system has been successfully demonstrated for detecting Pb2+ (0.01 mu g/L to 2100 mu g/ L) in river water (LOD = 0.00498 mu g/L), fish (LOD = 0.00566 mu g/L) and human serum samples (LOD = 0.00836 mu g/L), and the results were consistent with inductively coupled plasma-mass spectrometry (ICP-MS). The pro-posed novel sensing platform provides a cost-effectiveness, rapidly responding and ease-to-use pathway for analysis of heavy metal ions in real samples and shows great potential in point-of-care testing.
引用
收藏
页数:15
相关论文
共 73 条
[71]   ZnSe quantum dot based ion imprinting technology for fluorescence detecting cadmium and lead ions on a three-dimensional rotary paper-based microfluidic chip [J].
Zhou, Junrui ;
Li, Bowei ;
Qi, Anjin ;
Shi, Yajun ;
Qi, Ji ;
Xu, Huizhong ;
Chen, Lingxin .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 305
[72]   Graphene and Graphene Oxide: Synthesis, Properties, and Applications [J].
Zhu, Yanwu ;
Murali, Shanthi ;
Cai, Weiwei ;
Li, Xuesong ;
Suk, Ji Won ;
Potts, Jeffrey R. ;
Ruoff, Rodney S. .
ADVANCED MATERIALS, 2010, 22 (35) :3906-3924
[73]   Spinel NiCo2O4 for use as a high-performance supercapacitor electrode material: Understanding of its electrochemical properties [J].
Zhu, Yirong ;
Ji, Xiaobo ;
Wu, Zhengping ;
Song, Weixin ;
Hou, Hongshuai ;
Wu, Zhibin ;
He, Xiao ;
Chen, Qiyuan ;
Banks, Craig E. .
JOURNAL OF POWER SOURCES, 2014, 267 :888-900