Cystic Echinococcosis of the Liver: Correlation Between Intra-Operative Ultrasound and Pre-Operative Imaging

被引:7
|
作者
Trigui, Aymen [1 ,7 ]
Toumi, Nozha [2 ]
Fendri, Sami [1 ]
Saumtally, Mohammad Saad [1 ]
Zribi, Imen [4 ]
Akrout, Amira [1 ]
Mzali, Rafik [1 ]
Ketata, Salma [3 ]
Dziri, Chadli [5 ,6 ]
Ben Amar, Mohamed [1 ]
Boujelbene, Salah [1 ]
机构
[1] Univ Sfax, Habib Bourguiba Hosp, Fac Med, Dept Gen & Digest Surg, Sfax, Tunisia
[2] Univ Sfax, Habib Bourguiba Hosp, Fac Med, Dept Radiol, Sfax, Tunisia
[3] Univ Sfax, Habib Bourguiba Hosp, Fac Med, Dept Anesthesiol, Sfax, Tunisia
[4] Univ Sfax, Hop Reg Mahres, Fac Med, Dept Gen & Digest Surg, Sfax, Tunisia
[5] Univ Tunis El Manar, Gen Surg, Tunis, Tunisia
[6] Honoris Med Simulat Ctr, Tunis, Tunisia
[7] Habib Bourguiba Univ Hosp, Dept Gen & Digest Surg, Sfax 3029, Tunisia
关键词
computed tomography; diagnostic imaging; hepatic cystic echinococcosis; intra-operative ultrasound; SURGERY;
D O I
10.1089/sur.2023.335
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Imaging plays an essential role in the management of hepatic hydatid cysts (HCE). The objective of our study was to determine the correlation between pre-operative ultrasound, computed tomography (CT), and intra-operative ultrasound (IOUS) in studying the characteristics and complications of HCE.Patients and Methods: This was a prospective, descriptive, and analytical study conducted in the General Surgery Department of Habib Bourguiba Hospital in Sfax. The study included patients with HCE who underwent conservative surgery between April 2017 and June 2022.Results: We enrolled 49 patients with 94 cysts. At the end of our study, IOUS allowed for better detection of HCE (98.8%) regardless of the number of cysts per patient. IOUS and CT were accurate in studying the location of cysts (kappa = 1), whereas pre-operative abdominal ultrasound was less efficient (kappa = 0.870). IOUS was the best examination for detecting exocysts (kappa = 0.961), studying daughter cysts (kappa = 0.823), and exploring vascular relations, but it was less effective (kappa = 0.523) in detecting calcifications. Regarding classifications, ultrasound and CT had similar results. However, IOUS was most reliable in differentiating between CE3b and CE4 types (kappa = 0.653). Ultrasound, CT, and IOUS were not sensitive in detecting latent HCE suppurations and cystobiliary fistulas.Conclusions: Performing IOUS is essential to prevent recurrences and reduce post-operative morbidity.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 50 条
  • [41] Acute appendicitis and the role of pre-operative imaging: A cohort study
    Rait, Jaideep Singh
    Ajzajian, Jirayr
    McGillicuddy, Joshua
    Sharma, Amit
    Andrews, Brian
    ANNALS OF MEDICINE AND SURGERY, 2020, 59 : 258 - 263
  • [42] Utilization of Pre-Operative Imaging for Colon Cancer: A Population-Based Study
    McInnes, Matthew D. F.
    Nanji, Sulaiman
    Mackillop, William J.
    Flemming, Jennifer A.
    Wei, Xuejiao
    Macdonald, D. Blair
    Scheida, Nicola
    Booth, Christopher M.
    JOURNAL OF SURGICAL ONCOLOGY, 2017, 115 (02) : 202 - 207
  • [43] PRE-OPERATIVE DETECTION OF THYROID PYRAMIDAL LOBES BY ULTRASOUND AND COMPUTED TOMOGRAPHY
    Ryu, Ji Hwa
    Kim, Dong Wook
    Kang, Taewoo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (07) : 1442 - 1446
  • [44] Pre-operative assessment of intra-abdominal disease spread in epithelial ovarian cancer: a comparative study between ultrasound and computed tomography
    Luis Alcazar, Juan
    Caparros, Maria
    Arraiza, Maria
    Angel Minguez, Jose
    Guerriero, Stefano
    Chiva, Luis
    Jurado, Matias
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2019, 29 (02) : 227 - 233
  • [45] Pre-Operative Risk Factors Predict Post-Operative Respiratory Failure after Liver Transplantation
    Huang, Ching-Tzu
    Lin, Horng-Chyuan
    Chang, Shi-Chuan
    Lee, Wei-Chen
    PLOS ONE, 2011, 6 (08):
  • [46] Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery
    Beerekamp, M. S. H.
    Backes, M.
    Schep, N. W. L.
    Ubbink, D. T.
    Luitse, J. S.
    Schepers, T.
    Goslings, J. C.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (12) : 1667 - 1675
  • [47] Gallstone ileus: correlation between computed tomography, double-balloon enteroscopy and intra-operative findings
    Hartemink, Koen J.
    Hepp, Suzanne M.
    Pieters-van den Bos, Indra C.
    van Weyenberg, Stijn N. J. B.
    WIENER KLINISCHE WOCHENSCHRIFT, 2010, 122 (23-24) : 720 - 722
  • [48] Detailed liver-specific imaging prior to pre-operative chemotherapy for colorectal liver metastases reduces intra-hepatic recurrence and the need for a repeat hepatectomy
    Knowles, Brett
    Welsh, Fenella K. S.
    Chandrakumaran, Kandiah
    John, Tim G.
    Rees, Myrddin
    HPB, 2012, 14 (05) : 298 - 309
  • [49] Intra-operative ultrasound guidance of vena caval umbrella placement in a super obese patient
    Snyder, JM
    Arita, A
    Inampudi, C
    Gwin-Stewart, JA
    OBESITY SURGERY, 2002, 12 (05) : 679 - 681
  • [50] Brain Shift in Neuronavigation of Brain Tumors: An Updated Review of Intra-Operative Ultrasound Applications
    Gerard, Ian J.
    Kersten-Oertel, Marta
    Hall, Jeffery A.
    Sirhan, Denis
    Collins, D. Louis
    FRONTIERS IN ONCOLOGY, 2021, 10