Development of a human-size magnetic particle imaging device for sentinel lymph node biopsy of breast cancer

被引:4
作者
Bai, Shi [1 ,2 ]
Gai, Lingke [1 ]
Zhang, Qinyang [1 ]
Kang, Yue [3 ]
Liu, Zhiyao [1 ]
He, Yuan [1 ,4 ]
Liu, Wenzhong [5 ]
Jiang, Tao [6 ]
Du, Zhongzhou [7 ]
Du, Siyao [8 ]
Gao, Si [8 ]
Zhang, Min [8 ]
Li, Tianshu [1 ]
机构
[1] Shenyang Univ Technol, Sch Informat Sci & Engn, Shenyang, Peoples R China
[2] Liaoning Jiayin Med Technol Co Ltd, Liaoning Magnet Med Sensing & Treatment Technol In, Shenyang, Peoples R China
[3] China Med Univ, Dalian Univ Technol, Liaoning Canc Hosp & Inst, Dept Breast Surg,Canc Hosp, Shenyang, Peoples R China
[4] Keio Univ, Fac Sci & Technol, Yokohama, Japan
[5] Huazhong Univ Sci & Technol, Sch Artificial Intelligence & Automat, Wuhan, Peoples R China
[6] Nanjing Med Univ, Sch Biomed Engn & Informat, Nanjing, Peoples R China
[7] Zhengzhou Univ Light Ind, Dept Comp & Commun Engn, Zhengzhou, Peoples R China
[8] China Med Univ, Affiliated Hosp 1, Shenyang, Peoples R China
基金
中国国家自然科学基金;
关键词
human-sized MPI; field free point; third-harmonic signal; SPIONs; sentinel lymph node biopsy; IRON-OXIDE; DISSECTION; MORBIDITY;
D O I
10.3389/fbioe.2024.1327521
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study, a novel human-size handheld magnetic particle imaging (MPI) system was developed for the high-precision detection of sentinel lymph nodes for breast cancer. The system consisted of a highly sensitive home-made MPI detection probe, a set of concentric coils pair for spatialization, a solenoid coil for uniform excitation at 8 kHz@1.5 mT, and a full mirrored coil set positioned far away from the scanning area. The mirrored coils formed an extremely effective differential pickup structure which suppressed the system noise as high as 100 dB. The different combination of the inner and outer gradient current made the field free point (FFP) move in the Z direction with a uniform intensity of 0.54T/m, while the scanning in the XY direction was implemented mechanically. The third-harmonic signal of the Superparamagnetic Iron Oxide Nanoparticles (SPIONs) at the FFP was detected and then reconstructed synchronously with the current changes. Experiment results showed that the tomographic detection limit was 30 mm in the Z direction, and the sensitivity was about 10 mu g Fe SPIONs at 40 mm distance with a spatial resolution of about 5 mm. In the rat experiment, 54 mu g intramuscular injected SPIONs were detected successfully in the sentinel lymph node, in which the tracer content was about 1.2% total injected Fe. Additionally, the effective detection time window was confirmed from 4 to 6 min after injection. Relevant clinical ethics are already in the application process. Large mammalian SLNB MPI experiments and 3D preoperative SLNB imaging will be performed in the future.
引用
收藏
页数:7
相关论文
共 16 条
[1]   Using magnetic particle imaging systems to localize and guide magnetic hyperthermia treatment: tracers, hardware, and future medical applications [J].
Chandrasekharan, Prashant ;
Tay, Zhi Wei ;
Hensley, Daniel ;
Zhou, Xinyi Y. ;
Fung, Barry K. L. ;
Colson, Caylin ;
Lu, Yao ;
Fellows, Benjamin D. ;
Quincy Huynh ;
Saayujya, Chinmoy ;
Yu, Elaine ;
Orendorff, Ryan ;
Zheng, Bo ;
Goodwill, Patrick ;
Rinaldi, Carlos ;
Conolly, Steven .
THERANOSTICS, 2020, 10 (07) :2965-2981
[2]   Sentinel Node Biopsy Using a Magnetic Tracer Versus Standard Technique: The SentiMAG Multicentre Trial [J].
Douek, Michael ;
Klaase, Joost ;
Monypenny, Ian ;
Kothari, Ashutosh ;
Zechmeister, Katalin ;
Brown, Douglas ;
Wyld, Lynda ;
Drew, Philip ;
Garmo, Hans ;
Agbaje, Olorunsola ;
Pankhurst, Quentin ;
Anninga, Bauke ;
Grootendorst, Maarten ;
ten Haken, Bennie ;
Hall-Craggs, Margaret A. ;
Purushotham, Arnie ;
Pinder, Sarah .
ANNALS OF SURGICAL ONCOLOGY, 2014, 21 (04) :1237-1245
[3]   Tomographic imaging using the nonlinear response of magnetic particles [J].
Gleich, B ;
Weizenecker, R .
NATURE, 2005, 435 (7046) :1214-1217
[4]  
Knopp T., 2012, Magnetic Particle Imaging:An Introduction to Imaging Principles and Scanner Instrumentation
[5]   SURGICAL RESECTION AND RADIOLOCALIZATION OF THE SENTINEL LYMPH-NODE IN BREAST-CANCER USING A GAMMA-PROBE [J].
KRAG, DN ;
WEAVER, DL ;
ALEX, JC ;
FAIRBANK, JT .
SURGICAL ONCOLOGY-OXFORD, 1993, 2 (06) :335-340
[6]   Arm morbidity following sentinel lymph node biopsy or axillary lymph node dissection: A study from the Danish Breast Cancer Cooperative Group [J].
Madsen, Anders Husted ;
Haugaard, Karen ;
Soerensen, Jan ;
Bokmand, Susanne ;
Friis, Esbern ;
Holtveg, Helle ;
Garne, Jens Peter ;
Horby, John ;
Christiansen, Peer .
BREAST, 2008, 17 (02) :138-147
[7]   Single-sided device for magnetic particle imaging [J].
Sattel, Timo F. ;
Knopp, Tobias ;
Biederer, Sven ;
Gleich, Bernhard ;
Weizenecker, Juergen ;
Borgert, Joern ;
Buzug, Thorsten M. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2009, 42 (02)
[8]   Handheld magnetic probe with permanent magnet and Hall sensor for identifying sentinel lymph nodes in breast cancer patients [J].
Sekino, Masaki ;
Kuwahata, Akihiro ;
Ookubo, Tetsu ;
Shiozawa, Mikio ;
Ohashi, Kaichi ;
Kaneko, Miki ;
Saito, Itsuro ;
Inoue, Yusuke ;
Ohsaki, Hiroyuki ;
Takei, Hiroyuki ;
Kusakabe, Moriaki .
SCIENTIFIC REPORTS, 2018, 8
[9]   Sentinel lymph node biopsy in patients with breast cancer using superparamagnetic iron oxide and a magnetometer [J].
Shiozawa, Mikio ;
Lefor, Alan T. ;
Hozumi, Yasuo ;
Kurihara, Katsumi ;
Sata, Naohiro ;
Yasuda, Yoshikazu ;
Kusakabe, Moriaki .
BREAST CANCER, 2013, 20 (03) :223-229
[10]   Comparison of side effects between sentinel lymph node and axillary lymph node dissection for breast cancer [J].
Swenson, KK ;
Nissen, MJ ;
Ceronsky, C ;
Swenson, L ;
Lee, MW ;
Tuttle, TM .
ANNALS OF SURGICAL ONCOLOGY, 2002, 9 (08) :745-753