Limited view correction in low-optical-NA photoacoustic microscopy

被引:2
|
作者
Shen, Hao [1 ]
Liu, Xiangru [1 ,2 ]
Cui, Qi [1 ]
Sun, Yunxu [1 ]
Yang, Bing [3 ,4 ]
Li, Fenfang [5 ]
Xu, Xiaochuan [1 ]
Liu, Zhengjun [2 ]
Liu, Wei [1 ,4 ]
机构
[1] Harbin Inst Technol, Sch Elect & Informat Engn, Shenzhen, Peoples R China
[2] Harbin Inst Technol, Sch Phys, Harbin, Peoples R China
[3] Southern Univ Sci & Technol, Coll Sci, Shenzhen, Peoples R China
[4] Guangdong HongKong Macao Greater Bay Area, Quantum Sci Ctr, Shenzhen, Peoples R China
[5] Shenzhen Bay Lab, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
SPECKLE-FREE NATURE; TOMOGRAPHY; VISIBILITY;
D O I
10.1364/OL.502616
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Photoacoustic microscope (PAM) with a low-optical NA suffers from a limited view along the optical axis, due to the coherent cancellation of acoustic pressure waves after being excited with a smoothly focused beam. Using larger-NA (NA > 0.3) objectives can readily overcome the limited-view problem, while the consequences are the shallow working distance and time-consuming depth scanning for large volume imaging. Instead, we report an off-axis oblique detection strategy that is compatible with a low-optical-NA PAM for turning up the optical-axis structures. Comprehensive photoacoustic modeling and ex vivo phantom and in vivo mouse brain imaging experiments are conducted to validate the efficacy of correcting the limited view. Proof-of-concept experiment results show that the visibility of optical-axis structures can be greatly enhanced by making the detection angle off the optical axis larger than 45(degrees), strongly recommending that off-axis oblique detection is a simple and cost-effective alternative method to solve the limited-view problems in low-optical-NA PAMs. (c) 2023 Optica Publishing Group
引用
收藏
页码:5627 / 5630
页数:4
相关论文
共 50 条
  • [11] Noncontact broadband all-optical photoacoustic microscopy based on a low-coherence interferometer
    Chen, Zhongjiang
    Yang, Sihua
    Wang, Yi
    Xing, Da
    APPLIED PHYSICS LETTERS, 2015, 106 (04)
  • [12] Optical resolution photoacoustic microscopy based on multimode fibers
    Moothanchery, Mohesh
    Bi, Renzhe
    Kim, Jin Young
    Jeon, Seungwan
    Kim, Chulhong
    Olivo, Malini
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (03): : 1190 - 1197
  • [13] Digital aberration correction enhances field of view in visible-light optical coherence microscopy
    Glandorf, Lukas
    Marchand, Paul-James
    Lasser, Theo
    Razansky, Daniel
    OPTICS LETTERS, 2022, 47 (19) : 5088 - 5091
  • [14] Dual-view photoacoustic microscopy for quantitative cell nuclear imaging
    Cai, De
    Wong, Terence T. W.
    Zhu, Liren
    Shi, Junhui
    Chen, Sung-Liang
    Wang, Lihong V.
    OPTICS LETTERS, 2018, 43 (20) : 4875 - 4878
  • [15] High-speed optical resolution photoacoustic microscopy with MEMS scanner using a novel and simple distortion correction method
    Shintate, Ryo
    Ishii, Takuro
    Ahn, Joongho
    Kim, Jin Young
    Kim, Chulhong
    Saijo, Yoshifumi
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [16] Objective-free optical-resolution photoacoustic microscopy
    Kim, Chulhong
    Park, Sungjo
    Kim, Jongki
    Lee, Sungrae
    Lee, Changho
    Jeon, Mansik
    Kim, Jeehyun
    Oh, Kyunghwan
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [17] A commercialized photoacoustic microscopy system with switchable optical and acoustic resolutions
    Pu, Yang
    Bi, Renzhe
    Olivo, Malini
    Zhao, Xiaojie
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XI, 2018, 10486
  • [18] Optical coherence photoacoustic microscopy for in vivo multimodal retinal imaging
    Liu, Xiaojing
    Liu, Tan
    Wen, Rong
    Li, Yiwen
    Puliafito, Carmen A.
    Zhang, Hao F.
    Jiao, Shuliang
    OPTICS LETTERS, 2015, 40 (07) : 1370 - 1373
  • [19] Effect of Light Scattering on Optical-Resolution Photoacoustic Microscopy
    Liu, Yan
    Zhang, Chi
    Hu, Song
    Suzuki, Yuta
    Xu, Zhun
    Ferradal, Silvina
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [20] Reconstruction of initial pressure from limited view photoacoustic images using deep learning
    Waibel, Dominik
    Groehl, Janek
    Isensee, Fabian
    Kirchner, Thomas
    Maier-Hein, Klaus
    Maier-Hein, Lena
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494