Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach

被引:3
|
作者
Chemla, Denis [1 ]
Agnoletti, Davide [2 ,3 ]
Jozwiak, Mathieu [4 ,5 ]
Zhang, Yi [6 ,7 ]
Protogerou, Athanase D. [8 ]
Millasseau, Sandrine [9 ]
Blacher, Jacques [6 ]
机构
[1] Hop Marie Lannelongue, INSERM UMRS 999, F-92350 Le Plessis Robinson, France
[2] Univ Bologna, Hypertens & Cardiovasc Risk Res Ctr, Dept Med & Surg Sci, I-40138 Bologna, Italy
[3] IRCCS Azienda Osped Univ Bologna, Heart Chest & Vasc Dept, Cardiovasc Internal Med, I-40138 Bologna, Italy
[4] CHU Nice, Serv Med Intens Reanimat, F-06200 Nice, France
[5] Univ Cote dAzur, Unite Rech Clin Cote dAzur, UR2CA, F-06200 Nice, France
[6] Univ Paris Cite, Res Ctr Epidemiol & Biostat, Hotel Dieu, AP HP,Diag & Therapeut Ctr,Sorbonne Paris Cite,CRE, 1,Pl Parvis Notre Dame, F-75004 Paris CRESS, France
[7] Tongji Univ, Shanghai Peoples Hosp 10, Dept Cardiol, Sch Med, Middle Yanchang Rd 301, Shanghai 200072, Peoples R China
[8] Natl & Kapodistrian Univ Athens, Dept Med, Clin & Lab Pathophysiol, Cardiovasc Prevent & Res Unit, Athens 10679, Greece
[9] Pulse Wave Consulting, F-95320 St Leu La Foret, France
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 08期
关键词
central pressure; aortic pressure; arterial tonometry; central hemodynamics; mean arterial pressure; systolic blood pressure; EUROPEAN-SOCIETY; AORTIC PRESSURE; PULSE PRESSURE; WORKING GROUP; ACCURACY; DEVICES; AMPLIFICATION; CALIBRATION; MORTALITY;
D O I
10.3390/jpm13081244
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Backround. Central systolic blood pressure (cSBP) provides valuable clinical and physiological information. A recent invasive study showed that cSBP can be reliably estimated from mean (MBP) and diastolic (DBP) blood pressure. In this non-invasive study, we compared cSBP calculated using a Direct Central Blood Pressure estimation (DCBP = MBP2/DBP) with cSBP estimated by radial tonometry. Methods. Consecutive patients referred for cardiovascular assessment and prevention were prospectively included. Using applanation tonometry with SphygmoCor device, cSBP was estimated using an inbuilt generalized transfer function derived from radial pressure waveform, which was calibrated to oscillometric brachial SBP and DBP. The time-averaged MBP was calculated from the radial pulse waveform. The minimum acceptable error (DCBP-cSBP) was set at <= 5 (mean) and <= 8 mmHg (SD). Results. We included 160 patients (58 years, 54%men). The cSBP was 123.1 +/- 18.3 mmHg (range 86-181 mmHg). The (DCBP-cSBP) error was 1.4 +/- 4.9 mmHg. There was a linear relationship between cSBP and DCBP (R-2 = 0.93). Forty-seven patients (29%) had cSBP values >= 130 mmHg, and a DCBP value > 126 mmHg exhibited a sensitivity of 91.5% and specificity of 94.7% in discriminating this threshold (Youden index = 0.86; AUC = 0.965). Conclusions. Using the DCBP formula, radial tonometry allows for the robust estimation of cSBP without the need for a generalized transfer function. This finding may have implications for risk stratification.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Non-invasive estimation of central aortic pressure from radial artery tonometry by neural networks
    Varanini, M
    Massoni, M
    Marraccini, P
    Kozákovà, M
    Djukic, G
    Bamoshmoosh, M
    Testa, R
    Vittone, F
    Palombo, C
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 501 - 504
  • [2] Direct estimation of central systolic blood pressure from radial arterial tonometry
    Izzo, J.
    Kafle, P.
    Osmond, P.
    JOURNAL OF HYPERTENSION, 2008, 26 : S369 - S370
  • [3] 2.6 Non-Invasive Estimation of Exercise Central Blood Pressure by Radial Tonometry May be Underestimated Due to Brachial-To-Radial-Systolic-Blood-Pressure-Amplification and is Related to Upper Limb Blood Flow Velocity
    D. Picone
    R. Climie
    M. Keske
    J. Sharman
    Artery Research, 2014, 8 (4) : 124 - 125
  • [4] CENTRAL SYSTOLIC BLOOD PRESSURE ESTIMATION BY NON INVASIVE HUMERAL SYSTOLIC BLOOD PRESSURE AND QKD INTERVAL
    Cremer, A.
    Coulon, P.
    Gosse, P.
    Codjo, L.
    Asmar, R.
    Coste, P.
    JOURNAL OF HYPERTENSION, 2010, 28 : E84 - E85
  • [5] Non-Invasive Estimation of Systolic Blood Pressure and Diastolic Blood Pressure Using Photoplethysmograph Components
    Jeong, Incheol
    Jun, Sukhwan
    Um, Daeja
    Oh, Joonghwan
    Yoon, Hyungro
    YONSEI MEDICAL JOURNAL, 2010, 51 (03) : 345 - 353
  • [6] COMPARISON OF CENTRAL SYSTOLIC BLOOD PRESSURE (CSBP) ESTIMATED BY DIRECT CENTRAL BLOOD PRESSURE (DCBP) FORMULA AND RADIAL TONOMETRY BY SPIGMOCOR: AN INVASIVE VALIDATION STUDY
    Leone, Dario
    Vallelonga, Fabrizio
    Bruno, Giulia
    Fragapani, Salvatore
    Cesareo, Marco
    Airale, Lorenzo
    Mingrone, Giulia
    Milan, Alberto
    JOURNAL OF HYPERTENSION, 2024, 42
  • [7] Comparison of non-invasive central blood pressure measurements using applanation tonometry and automated oscillometric radial pulse wave analysis
    Trinkmann, F.
    Benck, U.
    Halder, J.
    Saur, J.
    Borggrefe, M.
    Akin, I.
    Kaden, J. J.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1160 - 1161
  • [8] Non-invasive assessment of central blood pressure by applanation tonometry. Pulse wave analysis
    Hermida Ameijeiras, Alvaro
    Lopez Paz, Jose Enrique
    Calvo Gomez, Carlos
    GALICIA CLINICA, 2012, 73 (04): : 161 - 168
  • [9] Central blood pressure: Non-invasive methods and technology for its estimation
    Papaioannou, T. G.
    Moris, D.
    Protogerou, A.
    Stefanadis, C.
    ARCHIVES OF HELLENIC MEDICINE, 2011, 28 (03): : 351 - 364
  • [10] Patient-specific non-invasive estimation of the aortic blood pressure waveform by ultrasound and tonometry
    Zhou, Shuran
    Xu, Kai
    Fang, Yi
    Alastruey, Jordi
    Vennin, Samuel
    Yang, Jun
    Wang, Junli
    Xu, Lisheng
    Wang, Xiaocheng
    Greenwald, Steve E.