Organ doses, effective dose, and cancer risk estimation from head and neck CT scans

被引:2
作者
Kamrani, Samira [1 ]
Kasraie, Nima [2 ]
Jahangiri, Fatemeh [3 ]
Khezerloo, Davood [4 ]
Sheikhzadeh, Peyman [5 ]
机构
[1] Shahid Beheshti Univ, Dept Med Radiat Engn, Tehran, Iran
[2] UT Southwestern Med Ctr, Dept Radiol, Dallas, TX USA
[3] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Dept Radiol, Tehran, Iran
[4] Tabriz Univ Med Sci, Fac Alliance Med Sci, Dept Radiol, Tabriz, Iran
[5] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Dept Nucl Med, Tehran, Iran
关键词
Head and neck; CT scan; Cancer risk; Organ dose; Effective dose; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE;
D O I
10.1016/j.radphyschem.2023.111163
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Purpose:The goal of this study was to calculate the organ doses, effective doses, and cancer risk from head and neck computed tomography (CT) scans. Material and methods:All patients underwent topogram, base, and cerebrum sequences during their head and neck examinations. Two techniques were used to determine the effective dose (ED). The first was based on the scanner derived dose length product, while the second involved using the software that calculated the organ and effective doses. Organ doses were computed using the tissue weighting factors from Report 103 by the International Commission on Radiation Protection (ICRP). The cancer risk values were calculated using web-based software that is based on the BEIR VII Phase 2 report. Results:There were 293 patients in this study (189 males, 104 females). The overall mean effective dose in the females was higher than that in the males (2.19 vs. 2.06 mSv). Male patients had a mean cancer risk of 0.011%, whereas female patients had a mean cancer risk of 0.015%. The younger females had much higher cancer risk values. Conclusion:The findings of this study will assist physicians in justifying and optimizing dose administration of head and neck CT examinations by weighing the benefits of diagnosis on the one hand and awareness of cancer risk on the other.
引用
收藏
页数:6
相关论文
共 29 条
  • [1] Cumulative radiation exposure, effective and organ dose estimation from multiple head CT scans in stroke patients
    Abuzaid, Mohamed M.
    Elshami, Wiam
    Sulieman, Abdelmoneim
    Bradley, David
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 199
  • [2] Estimation of radiation-induced cataract and cancer risks during routine CT head procedures
    Alkhorayef, M.
    Sulieman, A.
    Alonazi, B.
    Alnaaimi, M.
    Alduaij, M.
    Bradley, D.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 65 - 68
  • [3] Effective radiation doses in neck computed tomography scans
    Alzimami, Khalid
    Jambi, Layal
    Mattar, Essam
    Alenezi, Ahmed
    Alfuraih, Abdulrahman
    Salah, Hassan
    Rabbaa, Mohammad
    Abuljoud, Mohammad
    Alsafi, Khaled
    Alsubaie, Abdullah
    Sulieman, Abdelmoneim
    Bradley, David A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [4] [Anonymous], 2006, HLTH RISKS EXP LOW L
  • [5] [Anonymous], 2012, quality assurance program for computed tomography: diagnostic and therapy applications
  • [6] Radiation doses from head, neck, chest and abdominal CT examinations: an institutional dose report
    Atli, Eray
    Uyanik, Sadik Ahmet
    Oguslu, Umut
    Cenkeri, Halime Cevik
    Yilmaz, Birnur
    Gumus, Burcak
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (01) : 147 - 151
  • [7] Bongartz G., 1999, European guidelines on quality criteria for computed tomography
  • [8] VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients
    Ding, Aiping
    Gao, Yiming
    Liu, Haikuan
    Caracappa, Peter F.
    Long, Daniel J.
    Bolch, Wesley E.
    Liu, Bob
    Xu, X. George
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14) : 5601 - 5625
  • [9] Goodarzi A.H., 2022, J CHEM HLTH RISKS, DOI [10.22034/JCHR.2022.1945293.1457, DOI 10.22034/JCHR.2022.1945293.1457]
  • [10] Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program
    Hohl, C.
    Muehlenbruch, G.
    Wildberger, J. E.
    Leidecker, C.
    Suss, C.
    Schmidt, T.
    Guenther, R. W.
    Mahnken, A. H.
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (08) : 1841 - 1846