Experimental and computational investigation of complexing agents on copper dissolution for chemical mechanical polishing process

被引:14
作者
Hu, Lianjun [1 ]
Pan, Guofeng [2 ,3 ]
Chen, Qi [1 ]
Li, Lipeng [1 ]
Ma, Yunpeng [1 ]
Zhang, Yong [1 ]
机构
[1] Tianjin Univ Commerce, Sch Informat Engn, Tianjin 300134, Peoples R China
[2] Hebei Univ Technol, Sch Elect & Informat Engn, Tianjin 300130, Peoples R China
[3] Tianjin Key Lab Elect Mat & Devices, Tianjin 300130, Peoples R China
基金
中国国家自然科学基金;
关键词
Chemical mechanical polishing; Copper dissolution; Complexing agents; Density functional theory; Molecular dynamics simulation; MOLECULAR-DYNAMICS SIMULATION; CITRIC-ACID; INHIBITION PERFORMANCE; HYDROGEN-PEROXIDE; CMP; SURFACE; CORROSION; REMOVAL; GLYCINE; OXIDATION;
D O I
10.1016/j.colsurfa.2023.131142
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Complexing agents are important additives in chemical mechanical polishing (CMP) slurries, and they play key roles in the removal rate (RR) and surface quality of copper (Cu). However, it is a great challenge to clarify the complexing mechanism of Cu at the microscopic level. In this study, the effects of glycine (GLY), potassium tartrate (PT), and potassium citrate (CAK) on the RR and dissolution behavior of Cu are investigated. The results show that the complexing capability is in the order of GLY > PT > CAK. The complexing mechanism is elucidated by single-frequency electrochemical impedance spectroscopy, X-ray photoelectron spectroscopy, ultraviolet -visible spectrometer, density functional theory, and molecular dynamics simulation. Copper hydroxide (Cu (OH)2) on the Cu surface ionizes, giving rise to Cu2+ ions, which are attracted by negatively charged oxygen atoms of carboxylate groups in complexing agents, resulting in the formation of water-soluble complexes. This process destroys the integrity of the oxide layer on the Cu surface. Therefore, the oxide layer can be easily removed by a polishing pad. These findings provide significant theoretical guidance for the development of Cu CMP slurries in the microelectronics industry.
引用
收藏
页数:11
相关论文
共 54 条
  • [1] pH-dependent permeation of amino acids through isolated ivy cuticles is affected by cuticular water sorption and hydration shell size of the solute
    Arand, Katja
    Stock, David
    Burghardt, Markus
    Riederer, Markus
    [J]. JOURNAL OF EXPERIMENTAL BOTANY, 2010, 61 (14) : 3865 - 3873
  • [2] Babu S., 2016, ADV CHEM MECH PLANAR, DOI 10.1016/C2014-0-01445-1
  • [3] Effect of Potassium Tartrate on Removal Rate Selectivity of Co/TiN/TEOS for Cobalt "Buff Step" Chemical Mechanical Planarization
    Cheng, Yuanshen
    Wang, Shengli
    Wang, Chenwei
    Yang, Yundian
    Wang, Ru
    [J]. ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2020, 9 (04)
  • [4] A novel green chemical mechanical polishing for potassium dihydrogen phosphate using corn oil slurry
    Cui, X.
    Zhang, Z.
    Shi, C.
    Meng, F.
    Xu, G.
    Xie, W.
    Liu, Z.
    Wang, J.
    Wen, W.
    [J]. MATERIALS TODAY SUSTAINABILITY, 2022, 20
  • [5] X-RAY PHOTOELECTRON-SPECTROSCOPY ANALYSIS OF COPPER AND ZINC-OXIDES AND SULFIDES
    DEROUBAIX, G
    MARCUS, P
    [J]. SURFACE AND INTERFACE ANALYSIS, 1992, 18 (01) : 39 - 46
  • [6] Mechanism of copper removal during CMP in acidic H2O2 slurry
    Du, T
    Tamboli, D
    Desai, V
    Seal, S
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2004, 151 (04) : G230 - G235
  • [7] Effect of hydrogen peroxide on oxidation of copper in CMP slurries containing glycine and Cu ions
    Du, T
    Vijayakumar, A
    Desai, V
    [J]. ELECTROCHIMICA ACTA, 2004, 49 (25) : 4505 - 4512
  • [8] Frisch G. W. T. M. J., 2009, Gaussian 09, DOI 10.1159/000348293
  • [9] Comparing Methods for Predicting the Reactive Site of Electrophilic Substitution
    Fu Rong
    Lu Tian
    Chen Fei-Wu
    [J]. ACTA PHYSICO-CHIMICA SINICA, 2014, 30 (04) : 628 - 639
  • [10] INITIAL AND FINAL-STATE EFFECTS IN ESCA SPECTRA OF CADMIUM AND SILVER-OXIDES