First approach for the voltammetric sensing of rifabutin by the use of cationic surfactant media on the boron-doped diamond electrode

被引:11
作者
Barzani, Hemn A. H. [1 ,2 ]
Yardim, Yavuz [3 ]
机构
[1] Van Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkiye
[2] Aynda Private Tech Inst, Dept Pharm, Erbil 44001, Iraq
[3] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkiye
关键词
Rifabutin; Cationic surfactant; Boron-doped diamond electrode; Voltammetry; Pharmaceutical formulation; PERFORMANCE LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL FORMULATIONS; ANTITUBERCULOSIS DRUGS; ANIONIC SURFACTANT; HUMAN PLASMA; TUBERCULOSIS; RIFAMPIN; QUANTIFICATION; METABOLITES; RIFAPENTINE;
D O I
10.1016/j.diamond.2022.109658
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An excellent electrochemical sensor for determining rifabutin (RFB) by square-wave voltammetry was developed utilizing a non-modified boron-doped diamond electrode. Measurements of RFB using cyclic voltammetry with Britton-Robinson buffer (BR, 0.04 M, pH 7.0) solution revealed irreversible behaviour, diffusion-controlled as well as well-defined two oxidation peaks at around +0.67 (PA1) and + 1.23 (PA2) V vs Ag/AgCl. RFB oxidations depend critically on pH and supporting electrolytes. The anodic peak currents of the RFB were enormously enhanced by adding cetyltrimethylammonium bromide (CTAB, cationic surfactant) in the chosen supporting electrolyte, mainly when accumulating conditions were utilized. RFB was quantified using its two anodic peaks. By using optimized procedures also instrumental variables, the current response via RFB is proportionally linear throughout the concentration range of 0.1 to 10.0 mu g mL-1 (1.18 x 10-7-1.18 x 10-5 M) via a detection limit of 0.030 mu g mL-1 (3.54 x 10-8 M) for PA1 and 0.026 mu g mL-1 (3.07 x 10-8 M) for PA2 in BR buffer (PH 7.0) solution. Ultimately, the proposed approach was accurately utilized to evaluate RFB in pharmaceutical formu-lation. To the greatest of our knowledge, this is the first approach for electroanalytical determination of RFB.
引用
收藏
页数:9
相关论文
共 55 条
  • [1] Electroanalytical investigation and voltammetric quantification of antiviral drug favipiravir in the pharmaceutical formulation and urine sample using a glassy carbon electrode in anionic surfactant media
    Akca, Zeynep
    Ozok, Hande Izem
    Yardim, Yavuz
    Senturk, Zuhre
    [J]. TURKISH JOURNAL OF CHEMISTRY, 2022, 46 (03) : 869 - 880
  • [2] First electrochemical study of a potent antifungal drug caspofungin: Application to its enhanced voltammetric sensing based on the performance of boron-doped diamond electrode in CTAB-mediated measurements
    Ali, Hoshyar Saadi
    Barzani, Hemn A. H.
    Yardim, Yavuz
    Senturk, Zuhre
    [J]. DIAMOND AND RELATED MATERIALS, 2022, 125
  • [3] Electrooxidation of tetracycline antibiotic demeclocycline at unmodified boron-doped diamond electrode and its enhancement determination in surfactant-containing media
    Allahverdiyeva, Shabnam
    Yardim, Yavuz
    Senturk, Zuhre
    [J]. TALANTA, 2021, 223
  • [4] Antituberculosis drugs: Drug interactions, adverse effects, and use in special situations. Part 1: First-line drugs
    Arbex, Marcos Abdo
    Lima Varella, Marilia de Castro
    de Siqueira, Helio Ribeiro
    Fiuza de Mello, Fernando Augusto
    [J]. JORNAL BRASILEIRO DE PNEUMOLOGIA, 2010, 36 (05) : 626 - 640
  • [5] Stability-Indicating Validated HPTLC Method for Simultaneous Analysis of Rifabutin and Isoniazid in Pharmaceutical Formulations
    Avachat, Amelia M.
    Bhise, Satish B.
    [J]. JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2010, 23 (02) : 123 - 128
  • [6] Rifabutin Is Active against Mycobacterium abscessus Complex
    Aziz, Dinah Binte
    Low, Jian Liang
    Wu, Mu-Lu
    Gengenbacher, Martin
    Teo, Jeanette W. P.
    Dartois, Veronique
    Dick, Thomas
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2017, 61 (06)
  • [7] Update on rifampin, rifabutin, and rifapentine drug interactions
    Baciewicz, Anne M.
    Chrisman, Cary R.
    Finch, Christopher K.
    Self, Timothy H.
    [J]. CURRENT MEDICAL RESEARCH AND OPINION, 2013, 29 (01) : 1 - 12
  • [8] Bard A. J., 2000, ELECTROCHEMICAL METH
  • [9] Determination of rifabutin by high-performance liquid chromatography using on-line concentration and column switching
    Bartels, H
    Bartels, R
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (02): : 235 - 240
  • [10] Developing an electroanalytical procedure for the determination of caffeic acid phenethyl ester at a boron-doped diamond electrode by the use of cationic surfactant media
    Barzani, Hemn A. H.
    Ali, Hoshyar Saadi
    Ozok, Hande Izem
    Yardim, Yavuz
    [J]. DIAMOND AND RELATED MATERIALS, 2022, 124