Deep learning-based motion compensation for four-dimensional cone-beam computed tomography (4D-CBCT) reconstruction

被引:17
作者
Zhang, Zhehao [1 ]
Liu, Jiaming [2 ]
Yang, Deshan [3 ]
Kamilov, Ulugbek S. [2 ,4 ]
Hugo, Geoffrey D. [1 ,4 ,5 ]
机构
[1] Washington Univ, Dept Radiat Oncol, Sch Med St Louis, St Louis, MO USA
[2] Washington Univ St Louis, Dept Elect & Syst Engn, St Louis, MO USA
[3] Duke Univ, Dept Radiat Oncol, Sch Med, Durham, NC USA
[4] Washington Univ St Louis, Dept Comp Sci & Engn, St Louis, MO USA
[5] Washington Univ, Sch Med St Louis, Dept Radiat Oncol, 4921 Parkview Pl, St Louis, MO 63110 USA
关键词
4D-CBCT; deep learning; motion compensation; ARTIFACTS;
D O I
10.1002/mp.16103
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMotion-compensated (MoCo) reconstruction shows great promise in improving four-dimensional cone-beam computed tomography (4D-CBCT) image quality. MoCo reconstruction for a 4D-CBCT could be more accurate using motion information at the CBCT imaging time than that obtained from previous 4D-CT scans. However, such data-driven approaches are hampered by the quality of initial 4D-CBCT images used for motion modeling. PurposeThis study aims to develop a deep-learning method to generate high-quality motion models for MoCo reconstruction to improve the quality of final 4D-CBCT images. MethodsA 3D artifact-reduction convolutional neural network (CNN) was proposed to improve conventional phase-correlated Feldkamp-Davis-Kress (PCF) reconstructions by reducing undersampling-induced streaking artifacts while maintaining motion information. The CNN-generated artifact-mitigated 4D-CBCT images (CNN enhanced) were then used to build a motion model which was used by MoCo reconstruction (CNN+MoCo). The proposed procedure was evaluated using in-vivo patient datasets, an extended cardiac-torso (XCAT) phantom, and the public SPARE challenge datasets. The quality of reconstructed images for XCAT phantom and SPARE datasets was quantitatively assessed using root-mean-square-error (RMSE) and normalized cross-correlation (NCC). ResultsThe trained CNN effectively reduced the streaking artifacts of PCF CBCT images for all datasets. More detailed structures can be recovered using the proposed CNN+MoCo reconstruction procedure. XCAT phantom experiments showed that the accuracy of estimated motion model using CNN enhanced images was greatly improved over PCF. CNN+MoCo showed lower RMSE and higher NCC compared to PCF, CNN enhanced and conventional MoCo. For the SPARE datasets, the average (+/- standard deviation) RMSE in mm(-1) for body region of PCF, CNN enhanced, conventional MoCo and CNN+MoCo were 0.0040 +/- 0.0009, 0.0029 +/- 0.0002, 0.0024 +/- 0.0003 and 0.0021 +/- 0.0003. Corresponding NCC were 0.84 +/- 0.05, 0.91 +/- 0.05, 0.91 +/- 0.05 and 0.93 +/- 0.04. ConclusionsCNN-based artifact reduction can substantially reduce the artifacts in the initial 4D-CBCT images. The improved images could be used to enhance the motion modeling and ultimately improve the quality of the final 4D-CBCT images reconstructed using MoCo.
引用
收藏
页码:808 / 820
页数:13
相关论文
共 38 条
[11]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[12]   Augmentation of CBCT Reconstructed From Under-Sampled Projections Using Deep Learning [J].
Jiang, Zhuoran ;
Chen, Yingxuan ;
Zhang, Yawei ;
Ge, Yun ;
Yin, Fang-Fang ;
Ren, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (11) :2705-2715
[13]  
Joseph P M, 1982, IEEE Trans Med Imaging, V1, P192, DOI 10.1109/TMI.1982.4307572
[14]   The management of respiratory motion in radiation oncology report of AAPM Task Group 76 [J].
Keall, Paul J. ;
Mageras, Gig S. ;
Balter, James M. ;
Emery, Richard S. ;
Forster, Kenneth M. ;
Jiang, Steve B. ;
Kapatoes, Jeffrey M. ;
Low, Daniel A. ;
Murphy, Martin J. ;
Murray, Brad R. ;
Ramsey, Chester R. ;
Van Herk, Marcel B. ;
Vedam, S. Sastry ;
Wong, John W. ;
Yorke, Ellen .
MEDICAL PHYSICS, 2006, 33 (10) :3874-3900
[15]  
Kingma DP, 2014, ADV NEUR IN, V27
[16]   elastix: A Toolbox for Intensity-Based Medical Image Registration [J].
Klein, Stefan ;
Staring, Marius ;
Murphy, Keelin ;
Viergever, Max A. ;
Pluim, Josien P. W. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) :196-205
[17]   Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing [J].
La Rivière, PJ ;
Billmire, DM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (01) :105-111
[18]   High temporal resolution and streak-free four-dimensional cone-beam computed tomography [J].
Leng, Shuai ;
Tang, Jie ;
Zambelli, Joseph ;
Nett, Brian ;
Tolakanahalli, Ranjini ;
Chen, Guang-Hong .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20) :5653-5673
[19]   Motion correction for improved target localization with on-board cone-beam computed tomography [J].
Li, T ;
Schreibmann, E ;
Yang, Y ;
Xing, L .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02) :253-267
[20]   Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy [J].
Li, Tianfang ;
Xing, Lei .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :1211-1219