Effects of Ionizing Radiation on Cardiac Implantable Electronic Devices (CIEDs) in Patients with Esophageal Cancer Undergoing Radiotherapy: A Pilot Study

被引:0
|
作者
Uzun, Davut D. [1 ,2 ,3 ]
Salatzki, Janek [2 ,3 ]
Xynogalos, Panagiotis [2 ,3 ]
Frey, Norbert [2 ,3 ]
Debus, Juergen [4 ,5 ,6 ,7 ,8 ,9 ]
Lang, Kristin [4 ,5 ,6 ]
机构
[1] Heidelberg Univ Hosp, Dept Anesthesiol, D-69120 Heidelberg, Germany
[2] Heidelberg Ctr Heart Rhythm Disorders HCR, D-69120 Heidelberg, Germany
[3] Heidelberg Univ Hosp, Dept Cardiol, D-69120 Heidelberg, Germany
[4] Heidelberg Univ Hosp, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[5] Heidelberg Inst Radiat Oncol HIRO, D-69120 Heidelberg, Germany
[6] Natl Ctr Tumor Dis NCT, D-69120 Heidelberg, Germany
[7] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[8] German Canc Res Ctr, Clin Cooperat Unit Radiat Oncol, D-69120 Heidelberg, Germany
[9] German Canc Consortium DKTK, Partner Site Heidelberg, D-69120 Heidelberg, Germany
关键词
radiotherapy; esophageal cancer; cardiac devices; toxicity; CARDIOVERTER-DEFIBRILLATORS; THERAPY; CHEMORADIOTHERAPY; RISK; MALFUNCTION; PACEMAKERS; EXPOSURE; ENERGY;
D O I
10.3390/cancers16030555
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The number of cancer patients who require an implantable electronic heart device due to their heart disease is steadily increasing. Radiotherapy is an important treatment option for esophageal cancer, in addition to surgery and chemotherapy. Ionizing radiation can lead to serious malfunctions of cardiac devices, including complete loss of function with life-threatening consequences. There is already data in the literature on other types of cancer and radiotherapy. Esophageal cancer is rare, so there is limited information on patients with this cancer who need radiotherapy and have an electronic heart device. We retrospectively analyzed the occurrence of cardiac device malfunction in patients with esophageal cancer in our study between 2012 and 2022. By applying our internal treatment protocol, serious cardiac device malfunctions during, and after radiotherapy could be prevented. It is important to carefully plan and select the energy of the photons. The manufacturer's recommended dose limits should be observed.Abstract (1) Background: The prevalence of cancer patients relying on cardiac implantable electronic device (CIED) is steadily rising. The aim of this study was to evaluate RT-related malfunctions of CIEDs. (2) Methods: We retrospectively analyze sixteen patients with esophageal cancer who were treated with radiotherapy between 2012 and 2022 at the University Hospital Heidelberg. All patients underwent systemic evaluation including pre-therapeutic cardiological examinations of the CIED functionality and after every single irradiation. (3) Results: Sixteen patients, predominantly male (14) with a mean age of 77 (range: 56-85) years were enrolled. All patients received 28 fractions of radiotherapy with a cumulative total dose 58.8 Gy. The mean maximum dose at the CIEDs was 1.8 Gy. Following radiotherapy and during the one-year post-radiation follow-up period, there were no registered events associated with the treatment in this evaluation. (4) Conclusion: The study did not observe any severe CIED malfunctions following each radiation fraction or after completion of RT. Strict selection of photon energy and alignment with manufacturer-recommended dose limits appear to be important. Our study showed no major differences in the measured values of the pacing threshold, sensing threshold and lead impedance after RT.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Radiotherapy-induced malfunctions of cardiac implantable electronic devices in cancer patients
    Vincenzo L. Malavasi
    Giuseppina De Marco
    Jacopo F. Imberti
    Filippo Placentino
    Marco Vitolo
    Ercole Mazzeo
    Gianfranco Cicoria
    Edoardo Casali
    Vincenzo Turco
    Frank Lohr
    Giuseppe Boriani
    Internal and Emergency Medicine, 2020, 15 : 967 - 973
  • [22] Radiotherapy of patients with cardiac implantable electronic devices according to the DEGRO/DGK guideline-is the risk of relevant errors overestimated?
    Steger, Felix
    Hautmann, Matthias G.
    Suess, Christoph
    Hubauer, Ute
    Uecer, Ekrem
    Maier, Lars
    Koelbl, Oliver
    Jungbauer, Carsten
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1086 - 1093
  • [23] Radiotherapy in patients with cardiac implantable electronic devices: clinical and dosimetric aspects
    Giulia Riva
    Ombretta Alessandro
    Ruggero Spoto
    Annamaria Ferrari
    Cristina Garibaldi
    Federica Cattani
    Rosa Luraschi
    Elena Rondi
    Nicola Colombo
    Fulvio Lorenzo Francesco Giovenzana
    Carlo Maria Cipolla
    Mikolaj Winnicki
    Martina Persiani
    Fabiana Castelluccia
    Massimo Sarra Fiore
    Roberto Orecchia
    Barbara Alicja Jereczek-Fossa
    Medical Oncology, 2018, 35
  • [24] Management of Patients with Cardiovascular Implantable Electronic Devices Undergoing Radiation Therapy: A National Survey of Canadian Multidisciplinary Radiation Oncology Professionals
    Safavi, Amir H.
    Louie, Alexander, V
    Elzibak, Alyaa H.
    Warner, Andrew
    Donovan, Elysia K.
    Detsky, Jay S.
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (04)
  • [25] Infective endocarditis in patients with cardiac implantable electronic devices: a nationwide study
    Mateos Gaitan, Roberto
    Boix-Palop, Lucia
    Munoz Garcia, Patricia
    Mestres, Carlos A.
    Marin Arriaza, Mercedes
    Pedraz Prieto, Alvaro
    de Alarcon Gonzalez, Aristides
    Gutierrez Carretero, Encarnacion
    Hernandez Meneses, Marta
    Goenaga Sanchez, Miguel Angel
    Cobo Belaustegui, Manuel
    Oteo Revuelta, Jose Antonio
    Gainzarain Arana, Juan Carlos
    Garcia Vazquez, Elisa
    Martinez-Selles, Manuel
    EUROPACE, 2020, 22 (07): : 1062 - 1070
  • [26] Baseline nutritional status could be a predictor for radiation esophagitis in esophageal cancer patients undergoing radiotherapy
    Dong, Jie
    Zhang, Wencheng
    Zhang, Tian
    Chen, Xi
    Zhao, Jingjing
    Zeng, Yaqi
    Chen, Yajun
    Wei, Xiaoying
    Lei, Tongda
    Wang, Ping
    Zhao, Lujun
    Wang, Jun
    Yuan, Zhiyong
    Song, Yongchun
    Liu, Ningbo
    Wang, Kun
    Pang, Qingsong
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (18)
  • [27] Disparities in Care Among Patients With Cardiac Implantable Electronic Devices Undergoing MRI
    Cavallo, Joseph J.
    Zhang, Yapei
    Staib, Lawrence H.
    Lampert, Rachel
    Weinreb, Jeffrey C.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (12) : 1566 - 1571
  • [28] Cardiac troponin T in patients with cardiac implantable electronic devices undergoing magnetic resonance imaging
    Higgins, John V.
    Watson, Robert E., Jr.
    Jaffe, Allan S.
    Dalzell, Connie
    Acker, Nancy
    Felmlee, Joel P.
    Asirvatham, Samuel J.
    Cha, Yong-Mei
    Friedman, Paul A.
    Kapa, Suraj
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 45 (01) : 91 - 97
  • [29] Dosimetric study to assess the feasibility of intraoperative radiotherapy with electrons (ELIOT) as partial breast irradiation for patients with cardiac implantable electronic device (CIED)
    Luraschi, Rosa
    Lazzari, Roberta
    Galimberti, Viviana
    Rondi, Elena
    Bazani, Alessia
    Corso, Giovanni
    Colombo, Nicola
    Ricotti, Rosalinda
    Fodor, Cristiana
    Winnicki, Mikolaj
    Leonardi, Maria Cristina
    Jereczek-Fossa, Barbara Alicja
    Cattani, Federica
    BREAST CANCER RESEARCH AND TREATMENT, 2018, 171 (03) : 693 - 699
  • [30] Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study
    Lim, Paul Chun Yih
    Lee, Audry Shan Yin
    Chua, Kelvin Chi Ming
    Lim, Eric Tien Siang
    Chong, Daniel Thuan Tee
    Tan, Boon Yew
    Ho, Kah Leng
    Teo, Wee Siong
    Ching, Chi Keong
    SINGAPORE MEDICAL JOURNAL, 2016, 57 (07) : 372 - 377