Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors

被引:1
作者
Jin, Zhicheng [1 ,4 ]
Huang, Rongrong [2 ]
Christensen, Paul [1 ,3 ]
Bertholf, Roger L. [1 ,3 ]
Yi, Xin [1 ,3 ]
机构
[1] Houston Methodist Hosp, Dept Pathol & Genom Med, Houston, TX 77030 USA
[2] Baylor Coll Med, Harris Hlth Syst Ben Taub Hosp, Dept Pathol & Immunol, Houston, TX 77030 USA
[3] Weill Cornell Med Coll, Dept Pathol & Lab Med, New York, NY 10065 USA
[4] Univ Wisconsin, Dept Pathol & Lab Med, Madison, WI 53792 USA
关键词
glomerular filtration rate; plasma iohexol clearance; LC-MS/MS; CLINICAL-PRACTICE; GFR; SINGLE; IOTHALAMATE; CR-51-EDTA; MULTIPLE;
D O I
10.3390/jcm12186054
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An accurate measurement of the glomerular filtration rate (GFR) is essential for detecting renal insufficiency in living kidney donors. Iohexol is a "near-ideal" exogenous filtration marker for GFR measurements that has attracted increasing interest in clinical practice because it is non-toxic, non-radioactive, readily available, and easy to measure. In this study, we aimed to set up a laboratory test to conveniently assess the plasma clearance of iohexol in living kidney donors. Methods: A workflow was established in the institution's infusion clinic to administer iohexol and to collect three timed blood samples from renal transplant donors. Iohexol was thereafter measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The serum proteins were precipitated and the supernatant containing iohexol was diluted prior to the LC-MS/MS analysis. The LC-MS/MS method was developed on a Thermo Vanquish UHPLC coupled with a TSQ Endura triple quadruple mass spectrometer with a total run time of 2.5 min. The analytical performance of the method was assessed. Results: The LC-MS/MS method demonstrated a good analytical performance. To calculate the iohexol clearance rate and the GFR, automated data integration and a result calculation were accomplished by using a custom Python script. Automated result reporting was achieved using a laboratory informatics system (LIS) vendor's direct media interface. Conclusions: We developed and implemented a laboratory test to assess the plasma clearance of iohexol. A workflow was established in the hospital to reliably measure the GFR in living kidney donors, with a potential to be further expanded into other areas where an accurate GFR measurement is needed.
引用
收藏
页数:11
相关论文
共 27 条
  • [1] Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Assay for Iohexol in Human Serum
    Annesley, Thomas M.
    Clayton, Larry T.
    [J]. CLINICAL CHEMISTRY, 2009, 55 (06) : 1196 - 1202
  • [2] Comparison of GFR Measurements Assessed From Single Versus Multiple Samples
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2009, 54 (02) : 278 - 288
  • [3] Blank Gary E, 2011, J Pathol Inform, V2, P14, DOI 10.4103/2153-3539.77176
  • [4] Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 2: Why to measure glomerular filtration rate with iohexol?
    Delanaye, Pierre
    Melsom, Toralf
    Ebert, Natalie
    Back, Sten-Erik
    Mariat, Christophe
    Cavalier, Etienne
    Bjork, Jonas
    Christensson, Anders
    Nyman, Ulf
    Porrini, Esteban
    Remuzzi, Giuseppe
    Ruggenenti, Piero
    Schaeffner, Elke
    Soveri, Inga
    Sterner, Gunnar
    Eriksen, Bjorn Odvar
    Gaspari, Flavio
    [J]. CLINICAL KIDNEY JOURNAL, 2016, 9 (05) : 700 - 704
  • [5] Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?
    Delanaye, Pierre
    Ebert, Natalie
    Melsom, Toralf
    Gaspari, Flavio
    Mariat, Christophe
    Cavalier, Etienne
    Bjork, Jonas
    Christensson, Anders
    Nyman, Ulf
    Porrini, Esteban
    Remuzzi, Giuseppe
    Ruggenenti, Piero
    Schaeffner, Elke
    Soveri, Inga
    Sterner, Gunnar
    Eriksen, Bjorn Odvar
    Back, Sten-Erik
    [J]. CLINICAL KIDNEY JOURNAL, 2016, 9 (05): : 682 - 699
  • [6] Simple HPLC-UV method for determination of iohexol, iothalamate, p-aminohippuric acid and n-acetyl-p-aminohippuric acid in human plasma and urine with ERPF, GFR and ERPF/GFR ratio determination using colorimetric analysis
    Farthing, D
    Sica, DA
    Fakhry, I
    Larus, T
    Ghosh, S
    Farthing, C
    Vranian, M
    Gehr, T
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 826 (1-2): : 267 - 272
  • [7] GASPARI F, 1995, J AM SOC NEPHROL, V6, P257
  • [8] A comparison of the plasma disappearance of iohexol and 99mTc-DTPA for the measurement of glomerular filtration rate (GFR) in diabetes
    Houlihan, C
    Scott, A
    Jenkins, M
    Parkin, D
    Osicka, T
    Jerums, G
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1999, 29 (05): : 693 - 700
  • [9] A METHOD FOR THE CALCULATION OF RENAL CLEARANCE BASED ON A SINGLE PLASMA SAMPLE
    JACOBSSON, L
    [J]. CLINICAL PHYSIOLOGY, 1983, 3 (04): : 297 - 305
  • [10] KDIGO Clinical Practice Guideline on the Evaluation and Care of Living Kidney Donors
    Lentine, Krista L.
    Kasiske, Bertram L.
    Levey, Andrew S.
    Adams, Patricia L.
    Alberu, Josefina
    Bakr, Mohamed A.
    Gallon, Lorenzo
    Garvey, Catherine A.
    Guleria, Sandeep
    Li, Philip Kam-Tao
    Segev, Dorry L.
    Taler, Sandra J.
    Tanabe, Kazunari
    Wright, Linda
    Zeier, Martin G.
    Cheung, Michael
    Garg, Amit X.
    [J]. TRANSPLANTATION, 2017, 101 : S7 - S109