Efficiency enhancements of a Monte Carlo beamlet based treatment planning process: implementation and parameter study

被引:6
|
作者
Mueller, S. [1 ]
Guyer, G.
Volken, W.
Frei, D.
Torelli, N.
Aebersold, D. M.
Manser, P.
Fix, M. K.
机构
[1] Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 04期
基金
瑞士国家科学基金会;
关键词
beamlet; efficiency; Monte Carlo; treatment planning; inverse planning; COMBINED MODULATED ELECTRON; PROTON-PHOTON TREATMENTS; DOSE CALCULATION; OPTIMIZATION; THERAPY; RADIOTHERAPY; IMRT; UNCERTAINTIES; GENERATION; ACCURACY;
D O I
10.1088/1361-6560/acb480
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The computational effort to perform beamlet calculation, plan optimization and final dose calculation of a treatment planning process (TPP) generating intensity modulated treatment plans is enormous, especially if Monte Carlo (MC) simulations are used for dose calculation. The goal of this work is to improve the computational efficiency of a fully MC based TPP for static and dynamic photon, electron and mixed photon-electron treatment techniques by implementing multiple methods and studying the influence of their parameters. Approach. A framework is implemented calculating MC beamlets efficiently in parallel on each available CPU core. The user can specify the desired statistical uncertainty of the beamlets, a fractional sparse dose threshold to save beamlets in a sparse format and minimal distances to the PTV surface from which 2 x 2 x 2 = 8 (medium) or even 4 x 4 x 4 = 64 (large) voxels are merged. The compromise between final plan quality and computational efficiency of beamlet calculation and optimization is studied for several parameter values to find a reasonable trade-off. For this purpose, four clinical and one academic case are considered with different treatment techniques. Main results. Setting the statistical uncertainty to 5% (photon beamlets) and 15% (electron beamlets), the fractional sparse dose threshold relative to the maximal beamlet dose to 0.1% and minimal distances for medium and large voxels to the PTV to 1 cm and 2 cm, respectively, does not lead to substantial degradation in final plan quality compared to using 2.5% (photon beamlets) and 5% (electron beamlets) statistical uncertainty and no sparse format nor voxel merging. Only OAR sparing is slightly degraded. Furthermore, computation times are reduced by about 58% (photon beamlets), 88% (electron beamlets) and 96% (optimization). Significance. Several methods are implemented improving computational efficiency of beamlet calculation and plan optimization of a fully MC based TPP without substantial degradation in final plan quality.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] The study of slag particle deposition process based on Monte Carlo simulation
    Lin, Kuo
    Shen, Zhongjie
    Liang, Qinfeng
    Xu, Jianliang
    Liu, Haifeng
    POWDER TECHNOLOGY, 2022, 407
  • [42] Monte Carlo Based Sprint Planning Under Uncertainties
    Marchwicka, Ewa
    VISION 2025: EDUCATION EXCELLENCE AND MANAGEMENT OF INNOVATIONS THROUGH SUSTAINABLE ECONOMIC COMPETITIVE ADVANTAGE, 2019, : 6959 - 6968
  • [43] Fast Monte Carlo Simulation-based Process Design and Planning for Carbon Nanotube Synthesis
    Cheng, Changqing
    Bukkapatnam, Satish T. S.
    Raff, Lionel
    Komanduri, Ranga
    44TH NORTH AMERICAN MANUFACTURING RESEARCH CONFERENCE, NAMRC 44, 2016, 5 : 1357 - 1368
  • [44] Electron beam modeling and commissioning for Monte Carlo treatment planning
    Jiang, SB
    Kapur, A
    Ma, CM
    MEDICAL PHYSICS, 2000, 27 (01) : 180 - 191
  • [45] Monte Carlo systems used for treatment planning and dose verification
    Brualla, Lorenzo
    Rodriguez, Miguel
    Lallena, Antonio M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 (04) : 243 - 259
  • [46] MCNP5 ELECTRON AND PHOTON MONTE CARLO CALCULATIONS COUPLED WITH RADIATION TREATMENT PLANNING SYSTEM PLUNC
    Abella, V.
    Miro, R.
    Juste, B.
    Verdu, G.
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 53 - 57
  • [47] CT-based Monte Carlo simulation tool for dosimetry planning and analysis
    DeMarco, JJ
    Solberg, TD
    Smathers, JB
    MEDICAL PHYSICS, 1998, 25 (01) : 1 - 11
  • [48] Clinical implementation of a Monte Carlo based independent TPS dose checking system
    Livingstone, A. G.
    Crowe, S. B.
    Sylvander, S.
    Kairn, T.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (03) : 1113 - 1123
  • [49] Clinical implementation of a Monte Carlo based independent TPS dose checking system
    A. G. Livingstone
    S. B. Crowe
    S. Sylvander
    T. Kairn
    Physical and Engineering Sciences in Medicine, 2020, 43 : 1113 - 1123
  • [50] Implementation of an efficient Monte Carlo calculation for CBCT scatter correction: phantom study
    Watson, Peter G. F.
    Mainegra-Hing, Ernesto
    Tomic, Nada
    Seuntjens, Jan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (04): : 216 - 227