Efficiency enhancements of a Monte Carlo beamlet based treatment planning process: implementation and parameter study

被引:6
|
作者
Mueller, S. [1 ]
Guyer, G.
Volken, W.
Frei, D.
Torelli, N.
Aebersold, D. M.
Manser, P.
Fix, M. K.
机构
[1] Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 04期
基金
瑞士国家科学基金会;
关键词
beamlet; efficiency; Monte Carlo; treatment planning; inverse planning; COMBINED MODULATED ELECTRON; PROTON-PHOTON TREATMENTS; DOSE CALCULATION; OPTIMIZATION; THERAPY; RADIOTHERAPY; IMRT; UNCERTAINTIES; GENERATION; ACCURACY;
D O I
10.1088/1361-6560/acb480
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The computational effort to perform beamlet calculation, plan optimization and final dose calculation of a treatment planning process (TPP) generating intensity modulated treatment plans is enormous, especially if Monte Carlo (MC) simulations are used for dose calculation. The goal of this work is to improve the computational efficiency of a fully MC based TPP for static and dynamic photon, electron and mixed photon-electron treatment techniques by implementing multiple methods and studying the influence of their parameters. Approach. A framework is implemented calculating MC beamlets efficiently in parallel on each available CPU core. The user can specify the desired statistical uncertainty of the beamlets, a fractional sparse dose threshold to save beamlets in a sparse format and minimal distances to the PTV surface from which 2 x 2 x 2 = 8 (medium) or even 4 x 4 x 4 = 64 (large) voxels are merged. The compromise between final plan quality and computational efficiency of beamlet calculation and optimization is studied for several parameter values to find a reasonable trade-off. For this purpose, four clinical and one academic case are considered with different treatment techniques. Main results. Setting the statistical uncertainty to 5% (photon beamlets) and 15% (electron beamlets), the fractional sparse dose threshold relative to the maximal beamlet dose to 0.1% and minimal distances for medium and large voxels to the PTV to 1 cm and 2 cm, respectively, does not lead to substantial degradation in final plan quality compared to using 2.5% (photon beamlets) and 5% (electron beamlets) statistical uncertainty and no sparse format nor voxel merging. Only OAR sparing is slightly degraded. Furthermore, computation times are reduced by about 58% (photon beamlets), 88% (electron beamlets) and 96% (optimization). Significance. Several methods are implemented improving computational efficiency of beamlet calculation and plan optimization of a fully MC based TPP without substantial degradation in final plan quality.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code
    Francescon, P
    Cora, S
    Chiovati, P
    MEDICAL PHYSICS, 2003, 30 (02) : 144 - 157
  • [22] Treatment planning for a small animal using Monte Carlo simulation
    Chow, James C. L.
    Leung, Michael K. K.
    MEDICAL PHYSICS, 2007, 34 (12) : 4810 - 4817
  • [23] Clinical implications of adopting Monte Carlo treatment planning for CyberKnife
    Sharma, Subhash C.
    Ott, Joseph T.
    Williams, Jamone B.
    Dickow, Danny
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 170 - 175
  • [24] Treatment planning aspects and Monte Carlo methods in proton therapy
    Fix, Michael K.
    Manser, Peter
    MODERN PHYSICS LETTERS A, 2015, 30 (17)
  • [25] Study of the NaI(Tl) efficiency by Monte Carlo method
    Jehouani, A
    Ichaoui, R
    Boulkheir, M
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 887 - 891
  • [26] Monte Carlo Beamlets in Inverse Treatment Planning
    Popescu, I. A.
    Bush, K. K.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1856 - +
  • [27] Experimental validation of Monte Carlo based treatment planning system in bone density equivalent media
    Radojcic, Djeni Smilovic
    Casar, Bozidar
    Rajlic, David
    Kolacio, Manda Svabic
    Mendez, Ignasi
    Obajdin, Nevena
    Debeljuh, Dea Dundara
    Jurkovic, Slaven
    RADIOLOGY AND ONCOLOGY, 2020, 54 (04) : 495 - 504
  • [28] Estimating statistical uncertainty of Monte Carlo efficiency-gain in the context of a correlated sampling Monte Carlo code for brachytherapy treatment planning with non-normal dose distribution
    Mukhopadhyay, Nitai D.
    Sampson, Andrew J.
    Deniz, Daniel
    Carlsson, Gudrun Alm
    Williamson, Jeffrey
    Malusek, Alexandr
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (01) : 315 - 323
  • [29] IOeRT conventional and FLASH treatment planning system implementation exploiting fast GPU Monte Carlo: The case of breast cancer
    Franciosini, G.
    Carlotti, D.
    Cattani, F.
    De Gregorio, A.
    De Liso, V.
    De Rosa, F.
    Di Francesco, M.
    Di Martino, F.
    Felici, G.
    Pensavalle, J. Harold
    Leonardi, M. C.
    Marafini, M.
    Muscato, A.
    Paiar, F.
    Patera, V.
    Poortmans, P.
    Sciubba, A.
    Schiavi, A.
    Toppi, M.
    Traini, G.
    Trigilio, A.
    Sarti, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 121
  • [30] Dose painting by means of Monte Carlo treatment planning at the voxel level
    Jimenez-Ortega, E.
    Ureba, A.
    Vargas, A.
    Baeza, J. A.
    Wals-Zurita, A.
    Garcia-Gomez, J.
    Barbeiro, A. R.
    Leal, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 339 - 344