Three-dimensional quantification of skeletal midfacial complex symmetry

被引:2
|
作者
Morgan, Nermin [1 ,2 ,3 ]
Shujaat, Sohaib [1 ,2 ,4 ]
Jazil, Omid [1 ,2 ]
Jacobs, Reinhilde [1 ,2 ,5 ]
机构
[1] Katholieke Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Kapucijnenvoer 33 Bus 7001, B-3000 Leuven, Belgium
[2] Univ Hosp Leuven, Oral & Maxillofacial Surg, Kapucijnenvoer 33 Bus 7001, B-3000 Leuven, Belgium
[3] Mansoura Univ, Fac Dent, Dept Oral Med, Mansoura, Egypt
[4] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Dent, Dept Maxillofacial Surg & Diagnost Sci, Riyadh, Saudi Arabia
[5] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
关键词
Midfacial complex; Symmetry; Automatic segmentation; CBCT; Mirroring reconstructive surgeries; Virtual surgical planning; FLUCTUATING ASYMMETRY; AIDED RECONSTRUCTION; ORBITAL FLOOR; SEGMENTATION; VALIDATION; FRACTURES; CT;
D O I
10.1007/s11548-022-02775-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Quantification of skeletal symmetry in a healthy population could have a strong impact on the reconstructive surgical procedures where mirroring of the contralateral healthy side acts as a clinical reference for the restoration of unilateral defects. Hence, the aim of this study was to three-dimensionally assess the symmetry of skeletal midfacial complex in skeletal class I patients. Methods A sample of 100 cone beam computed tomography (CBCT) scans (50 males, 50 females; age range: 19-40 years) were recruited. Automated segmentation of the skeletal midfacial complex was performed to create a three-dimensional (3D) virtual model using a convolutional neural network (CNN)-based segmentation tool. Thereafter, the segmented model was mirrored and registered to quantify skeletal symmetry using a color-coded conformance mapping based on a surface part comparison analysis. Results Overall, the mean and root-mean-square (RMS) differences between complete true and mirrored models were 0.14 +/- 0.12 and 0.87 +/- 0.21 mm, respectively. Female patients had a significantly more symmetrical midfacial complex (mean difference: 0.11 +/- 0.1 mm, RMS: 0.81 +/- 0.17 mm) compared to male patients (mean difference: 0.16 +/- 0.13 mm, RMS: 0.94 +/- 0.23 mm). No significant difference existed between left and right sides irrespective of the patient's gender. Conclusion The comparison between true and mirrored complete and left/right split midfacial complex showed symmetry within a clinically acceptable range of 1 mm, which justifies the applicability of using the mirroring technique. The presented data could act as a reference guide for surgeons during planning of reconstructive surgical procedures and outcome assessment at follow-up.
引用
收藏
页码:611 / 619
页数:9
相关论文
共 50 条
  • [1] Three-dimensional quantification of skeletal midfacial complex symmetry
    Nermin Morgan
    Sohaib Shujaat
    Omid Jazil
    Reinhilde Jacobs
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 611 - 619
  • [2] Three-dimensional quantification of the symmetry of normal facial movement
    Coulson, SE
    Croxson, GR
    Gilleard, WL
    OTOLOGY & NEUROTOLOGY, 2002, 23 (06) : 999 - 1002
  • [3] Spatially-dense three-dimensional analysis of the midfacial skeletal shape asymmetry in skeletal Class III patients
    Zhao, Guangpu
    Su, Xinyu
    Wen, Aonan
    Li, Yiming
    Wang, Yong
    Zhao, Yijiao
    He, Danqing
    Gu, Yan
    EUROPEAN JOURNAL OF ORTHODONTICS, 2025, 47 (02)
  • [4] Application of optimized three-dimensional digital surgical guide plates for complex midfacial fractures
    Xu, Guikun
    Zhang, Xiaojie
    Wang, Peihan
    Long, Jie
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (06): : 2005 - 2015
  • [5] Measuring Symmetry in Children With Unrepaired Cleft Lip: Defining a Standard for the Three-Dimensional Midfacial Reference Plane
    Wu, Jia
    Heike, Carrie
    Birgfeld, Craig
    Evans, Kelly
    Maga, Murat
    Morrison, Clinton
    Saltzman, Babette
    Shapiro, Linda
    Tse, Raymond
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2016, 53 (06): : 695 - 704
  • [6] Quantification of press elasticity in the forging of three-dimensional complex shapes
    Lu, B.
    Ou, H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2012, 226 (B3) : 466 - 477
  • [7] On three-dimensional mirror symmetry
    Dey, Anindya
    JOURNAL OF HIGH ENERGY PHYSICS, 2012, (04):
  • [8] On three-dimensional mirror symmetry
    Anindya Dey
    Journal of High Energy Physics, 2012
  • [9] Three-dimensional quantification of facial symmetry in adolescents using laser surface scanning
    Djordjevic, Jelena
    Toma, Arshed M.
    Zhurov, Alexei I.
    Richmond, Stephen
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (02) : 125 - 132
  • [10] QUANTIFICATION OF SYMMETRY, PARALLELISM, AND CONTINUITY AS CONTINUOUS DESIGN VARIABLES FOR THREE-DIMENSIONAL PRODUCT REPRESENTATIONS
    Valencia-Romero, Ambrosio
    Lugo, Jose E.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2016, VOL 7, 2016,