Daylighting Performance of CdTe Semi-Transparent Photovoltaic Skylights with Different Shapes for University Gymnasium Buildings

被引:3
作者
Wu, Yanpeng [1 ]
Li, Shaoxiong [1 ]
Gao, Xin [1 ]
Fan, Huifang [1 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Resource Engn, Beijing 100083, Peoples R China
基金
北京市自然科学基金;
关键词
university gymnasium; daylighting; dynamic daylighting performance; skylights; BIPV; ENERGY PERFORMANCE; SOLAR-CELLS; DESIGN; OPTIMIZATION; FACADES; WINDOW; VIEW;
D O I
10.3390/buildings14010241
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The daylighting environment in university gymnasiums affects daily teaching and sports training. However, direct sunlight, glare, and indoor overheating in summer are common problems. Semi-transparent photovoltaic glass can solve these issues by replacing shading facilities, blocking solar radiation, and generating electricity. This study examines the influence of different types of CdTe semi-transparent film photovoltaic glass on the daylighting environment of six typical university gymnasium skylights. The optimal types of CdTe semi-transparent film photovoltaic glass are determined by dynamic daylighting performance metrics DA, DAcon, DAmax, and UDI. The results show that, for instance, centralized rectangular skylights benefit from the 50-60% transmittance type, while centralized X-shaped skylights require the 70-80% transmittance type to enhance indoor daylighting. The research results offer specific recommendations based on skylight shapes and photovoltaic glass types and can provide a reference for the daylighting design of university gymnasium buildings with different forms of photovoltaic skylights in the future.
引用
收藏
页数:19
相关论文
共 49 条
  • [1] Daylighting design with lightscoop skylights: Towards an optimization of shape under overcast sky conditions
    Acosta, Ignacio
    Navarro, Jaime
    Sendra, Juan Jose
    [J]. ENERGY AND BUILDINGS, 2013, 60 : 232 - 238
  • [2] Thermal performance evaluation and energy saving potential of semi-transparent CdTe in Facade BIPV
    Alrashidi, Hameed
    Issa, Walid
    Sellami, Nazmi
    Sundaram, Senthilarasu
    Mallick, Tapas
    [J]. SOLAR ENERGY, 2022, 232 : 84 - 91
  • [3] Performance assessment of cadmium telluride-based semi-transparent glazing for power saving in facade buildings
    Alrashidi, Hameed
    Issa, Walid
    Sellami, Nazmi
    Ghosh, Aritra
    Mallick, Tapas K.
    Sundaram, Senthilarasu
    [J]. ENERGY AND BUILDINGS, 2020, 215
  • [4] Thermal performance of semitransparent CdTe BIPV window at temperate climate
    Alrashidi, Hameed
    Ghosh, Aritra
    Issa, Walid
    Sellami, Nazmi
    Mallick, Tapas. K.
    Sundaram, Senthilarasu
    [J]. SOLAR ENERGY, 2020, 195 : 536 - 543
  • [5] Assessment of the efficiency of window integrated CdTe based semi-transparent photovoltaic module
    Barman, Sankar
    Chowdhury, Amartya
    Mathur, Sanjay
    Mathur, Jyotirmay
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2018, 37 : 250 - 262
  • [6] A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design
    Carlucci, Salvatore
    Causone, Francesco
    De Rosa, Francesco
    Pagliano, Lorenzo
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 47 : 1016 - 1033
  • [7] Impact of BIPV windows on building energy consumption in street canyons: Model development and validation
    Chen, Liutao
    Zheng, Xing
    Yang, Jiachuan
    Yoon, Jong Ho
    [J]. ENERGY AND BUILDINGS, 2021, 249
  • [8] Investigation on the daylight and overall energy performance of semi-transparent photovoltaic facades in cold climatic regions of China
    Cheng, Yuanda
    Gao, Min
    Dong, Jiankai
    Jia, Jie
    Zhao, Xudong
    Li, Guiqiang
    [J]. APPLIED ENERGY, 2018, 232 : 517 - 526
  • [9] Parametric design and daylighting: A literature review
    Eltaweel, Ahmad
    Su, Yuehong
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 73 : 1086 - 1103
  • [10] Fan Q., 2020, THESIS TIANJIN U TIA