Comparison of augmentation effects of medial buttress plate versus trochanteric lag screw in the cannulated screw fixation of Pauwels type III femoral neck fractures: A retrospective clinical study

被引:2
|
作者
Shen, Longxiang [1 ]
Ye, Kai [1 ]
An, Zhiquan [1 ]
机构
[1] Shanghai Jiao Tong Univ Peoples Hosp 6, Dept Orthoped, Shanghai, Peoples R China
关键词
Femoral neck fractures; medial buttress plate; Pauwels type III fractures; trochanteric lag screw; INTERNAL-FIXATION; BIOMECHANICAL ANALYSIS; YOUNG-ADULTS; COMPRESSION; OUTCOMES;
D O I
10.5152/j.aott.2023.23066
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: This study aimed to compare the effects of a medial buttress plate (MBP) or a trochanteric lag screw (TLS) to augment cannulated screws (CSs) in fixing Pauwels type III femoral neck fractures.Methods: This retrospective study included 58 patients (21 female, 37 male; mean age = 46 years; age = 19-64 years) treated by CSs for Pauwels type III femoral neck fractures from 2014 to 2017. All the patients were divided into 2 groups based on the internal fixation patterns: the MBP-augmented group (group A, n = 26) and the TLS group (group B, n = 32). The mean age was 47 (range = 24-57) years in group A and 45 (range = 19-64) years in group B. The operation time, intraoperative blood loss, reduction quality, Harris score, and postoperative complications were recorded and compared between both groups.Results: All patients were followed up for an average of 44.8 months in group A and 47.3 months in group B (P = .406). No significant difference was noted in reduction quality (P = 1.000). However, group A had a longer operation time (100.2 vs. 64.3 minutes, P < .001) and greater intraoperative blood loss (153.1 vs. 30.0 mL, P < .001) than group B. At the final follow-up, the union rate was equal between group A (96.2%) and group B (90.6%) (P = .760). The mean bone union time was 21.6 weeks in group A and 23.6 weeks in group B (P = .431). The delayed union rate was lower in group A (0%) than in group B (15.6%) (P < .001). The incidence of postoperative complications in terms of implant failure (7.7% vs. 28.1%, P = .048) and femoral neck shortening (7.7% vs. 28.1%, P = .048) were lower in group A than in group B. No significant difference was noted in avascular femoral head necrosis (P = 1.000) and the Harris score (P = .659) between the 2 groups.Conclusion: In the surgical treatment of Pauwels type III femoral neck fractures, medial buttress plating can offer fewer complications but equal avascular femoral head necrosis rate and functional outcome compared to trochanteric screw application.
引用
收藏
页码:250 / 257
页数:111
相关论文
共 50 条
  • [41] Dynamic compression locking system versus multiple cannulated compression screw for the treatment of femoral neck fractures: a comparative study
    Shu, Dong-Ping
    Xiao, Ya-Ping
    Bei, Ming-Jian
    Ji, Tao
    Peng, Yong-Jun
    Ma, Bing
    Li, Shao-Gang
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [42] Comparison of dynamic hip screw with anti-rotation screw and femoral neck system internal fixation for the treatment of garden II-IV type femoral neck fractures
    Hong, Haisen
    Sha, Mo
    Chen, Zhangxin
    Li, Yanwei
    Kang, Liangqi
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (06) : 4009 - 4017
  • [43] Comparative Short-Term Outcomes of Femoral Neck System (FNS) and Cannulated Screw Fixation in Patients with Femoral Neck Fractures: A Multicenter Study
    Chung, HoeJeong
    Kim, Youngwoo
    Kook, Incheol
    Kwak, Ji Woong
    Hwang, Kyu Tae
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (02) : 184 - 193
  • [44] Effect analysis of medial bracing plate combined with cannulated screw in unstable femoral neck fracture assisted by surgical hip dislocation: a retrospective study
    Sun, Xin
    Yi, Gang
    Ao, Liang
    Zhou, Xin
    Zhang, Tao
    Guan, Tai-yuan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [45] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [46] New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate
    Anderson Freitas
    Ricardo Lourenço Bontempo
    Frank Anderson Ramos Azevedo
    Leonardo Rigobello Battaglion
    Marcos Noberto Giordano
    Fabrício Reichert Barin
    Vincenzo Giordano
    European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 : 1069 - 1075
  • [47] New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate
    Freitas, Anderson
    Bontempo, Ricardo Lourenco
    Ramos Azevedo, Frank Anderson
    Battaglion, Leonardo Rigobello
    Giordano, Marcos Noberto
    Barin, Fabricio Reichert
    Giordano, Vincenzo
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (06) : 1069 - 1075
  • [48] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [49] A Comparative Biomechanical Analysis of Fixation Devices for Unstable Femoral Neck Fractures: The Intertan Versus Cannulated Screws or a Dynamic Hip Screw
    Rupprecht, Martin
    Grossterlinden, Lars
    Ruecker, Andreas H.
    de Oliveira, Alexander Novo
    Sellenschloh, Kay
    Nuechtern, Jakob
    Pueschel, Klaus
    Morlock, Michael
    Rueger, Johannes Maria
    Lehmann, Wolfgang
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (03): : 625 - 634
  • [50] Biomechanical comparison of screw versus screw-plate fixation of type 2 Schatzker fractures of the lateral tibial plateau
    Boisrenoult, P
    Bricteux, S
    Beaufils, P
    Hardy, P
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (07): : 707 - 711