Influence of a Metal Artifact Reduction Filter on the Diagnostic Accuracy of Complete and Incomplete Vertical Root Fractures
被引:1
作者:
Dias-Junior, Luiz Carlos de Lima
[1
]
Correa, Marcio
[1
]
Porto, Olavo Cesar Lyra
[2
]
Estrela, Carlos
Teixeira, Cleonice da Silveira
[1
]
Garcia, Lucas da Fonseca Roberti
[1
,4
]
Bortoluzzi, Eduardo Antunes
[3
]
机构:
[1] Fed Univ Santa Catarina UFSC, Dept Dent, Florianopolis, SC, Brazil
[2] Univ Fed Goias, Sch Dent, Dept Endodont, Goiania, GO, Brazil
[3] Univ Louisville, Sch Dent, Dept Diag & Oral Hlth, Div Endodont, Louisville, KY USA
[4] Univ Fed Santa Catarina, Hlth Sci Ctr, Dept Dent, Endodont Div, Campus Reitor Joao David Ferreira Lima, BR-88040900 Florianopolis, SC, Brazil
关键词:
Artifacts;
cone-beam computed tomography;
diagnosis;
root canal filling materials;
tooth fractures;
BEAM COMPUTED-TOMOGRAPHY;
ENDODONTICALLY TREATED TEETH;
RADIOGRAPHY;
PREVALENCE;
ALGORITHM;
ALARA;
D O I:
10.1016/j.joen.2023.07.010
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Introduction: This study aimed to assess the influence of the e-vol DX BAR filter on the diagnostic accuracy of complete and incomplete vertical root fractures (VRFs). Methods: Twenty single-rooted teeth were selected. The tooth crowns were removed, and the root canals were prepared up to a 40/.06 instrument (ProTaper Next). Each specimen was scanned in a Prexion 3D cone-beam computed tomography (CBCT) device, in a dry human skull, in 4 different situations: no root canal filling, gutta-percha, fiberglass post, and metal post. The specimens were fractured in a universal testing machine by using a customized wedge. Each specimen was reinspected to confirm the presence of incomplete VRFs. Another set of CBCT scans was performed. Then, the fractures were completed in the uni-versal testing machine, the teeth were reinspected, and the CBCT images were acquired again. Images were assessed by using the e-Vol DX software system, with the BAR filter and with the original images, for the diagnosis of VRFs. Statistical analysis was performed by using the DeLong and McNemar tests for the comparison of the area under the receiver operating characteristic curves (AUC), accuracy, sensitivity, and specificity values. Results: The use of the BAR filter did not improve the diagnostic values of AUC, accuracy, sensitivity, and specificity in both fracture patterns (P . .05). Incomplete VRFs presented significantly lower AUC, accuracy, and sensitivity compared with complete VRFs (P , .0001). Conclusions: The BAR filter did not improve the diagnostic accuracy of VRFs. The intracanal materials also did not influence the diagnosis. Incomplete VRFs were highly associated with a decrease in sensitivity. (J Endod 2023;49:1352-1361.)
引用
收藏
页码:1352 / 1361
页数:10