Optimal Design of a Novel Large-Span Cable-Supported Steel-Concrete Composite Floor System

被引:0
作者
Tan, Meiwen [1 ,2 ]
Wu, Yifan [1 ,3 ]
Pan, Wenhao [1 ,4 ,5 ]
Liu, Guoming [3 ]
Chen, Wei [2 ,3 ]
机构
[1] Zhejiang Univ, Coll Civil Engn & Architecture, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ, Ctr Balance Architecture, Hangzhou 310028, Peoples R China
[3] Zhejiang Univ Co Ltd, Architectural Design & Res Inst, Hangzhou 310028, Peoples R China
[4] Key Lab Space Struct Zhejiang Prov, Hangzhou 310058, Peoples R China
[5] Zhejiang Univ, Innovat Ctr Yangtze River Delta, Future City Lab, Jiaxing 314100, Peoples R China
基金
中国国家自然科学基金;
关键词
cable-supported steel-concrete composite floor system; optimal design; long-span structures; economically equivalent steel consumption; beam string structure; non-linear programming (NLP); NONLINEAR-PROGRAMMING SOLUTION; COST OPTIMIZATION; MECHANICAL FEATURES; VIBRATION; BEAMS;
D O I
10.3390/buildings14010113
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper optimizes the design of a novel large-span cable-supported steel-concrete composite floor system in a simply supported single-span, single-strut configuration, aiming for cost-effective solutions and minimal steel consumption. The optimization considers various cross-sectional dimensions, adhering to building standards and engineering practices, and is based on a non-linear programming (NLP) algorithm. Parameters of live loads ranging from 2 to 10 kN/m2 and spans from 20 to 100 m are considered. The optimization results show that cable-supported composite floors with a single strut exhibit robust economic feasibility for spans of less than 80 m and live loads under 8 kN/m2. Compared to conventional composite floors with welded I-beams, the cable-supported system offers more cost-effective cross-sections and reduces steel consumption. The savings in economically equivalent steel consumption range from 20% to 60%. Discussion on the area ratio of cables to steel beam in the optimal cross-section reveals that the secondary load-bearing system (i.e., bending of the main beam with an effective span length of L/2) may require more steel in cases of ultra-large spans. Therefore, the economical efficiency of cable-supported composite beams with multiple struts and smaller effective span lengths warrants further exploration in future studies.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Adeli H., 2003, Parallel processing in structural engineering
  • [2] Adeli H., 2002, Advances in Design Optimization.
  • [3] Optimum cost design of reinforced concrete slabs using neural dynamics model
    Ahmadkhanlou, F
    Adeli, H
    [J]. ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2005, 18 (01) : 65 - 72
  • [4] The evolution of composite flooring systems: applications, testing, modelling and eurocode design approaches
    Ahmed, Inas Mahmood
    Tsavdaridis, Konstantinos Daniel
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 155 : 286 - 300
  • [5] An Q., 2018, Ph.D. Thesis
  • [6] Control of human-induced vibration of an innovative CSBS-CSCFS
    An, Qi
    Chen, Zhihua
    Ren, Qingying
    Liu, Hongbo
    Yan, Xiangyu
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 115 : 359 - 371
  • [7] [Anonymous], 2016, Code for Composite Structures
  • [8] [Anonymous], 2012, JGJ 257-2012
  • [9] [Anonymous], 2010, Code for design of concrete structures
  • [10] [Anonymous], 2017, 500172017 GB