Dosimetric and radiobiological comparison between conventional and hypofractionated breast treatment plans using the Halcyon system

被引:1
|
作者
Tai, Duong Thanh [1 ,2 ]
Phat, Luong Tien [3 ]
Ngoc Anh, Nguyen [4 ,5 ]
Sang, Huynh Van Tran [1 ]
Loc, Tran Minh [1 ]
Hai, Nguyen Xuan [6 ]
Sandwall, Peter A. [7 ]
Bradley, David [8 ,9 ]
Chow, James C. L. [10 ,11 ]
机构
[1] Nguyen Tat Thanh Univ, Fac Pharm, Ho Chi Minh City 70000, Vietnam
[2] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
[3] Univ Med Shing Mark Hosp, Dept Radiat Oncol, Bien Hoa, Vietnam
[4] PHENIKAA Univ, Fac Fundamental Sci, Hanoi, Vietnam
[5] PHENIKAA Res & Technol Inst PRATI, A&A Green Phoenix Grp JSC, Hanoi, Vietnam
[6] Dalat Nucl Res Inst, Da Lat, Vietnam
[7] OhioHealth, Mansfield Hosp, Dept Radiat Oncol, Mansfield, OH USA
[8] Sunway Univ, Ctr Appl Phys & Radiat Technol, Bandar Sunway 47500, Selangor, Malaysia
[9] Univ Surrey, Sch Math & Phys, Guildford, Surrey, England
[10] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[11] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
radiotherapy treatment plan; conventional fractionated (CF); hypofractionated (HF); breast cancer; radiobiology model; Halcyon; normal tissue complication probability (NTCP); tumor control probability (TCP); RADIOTHERAPY HYPOFRACTIONATION; UK STANDARDIZATION; RADIATION-THERAPY; DOSE-VOLUME; CANCER; BOOST; FRACTIONATION; TRIAL; NTCP; SIZE;
D O I
10.3389/fonc.2023.1259416
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeThe objective of this research is to compare the efficacy of conventional and hypofractionated radiotherapy treatment plans for breast cancer patients, with a specific focus on the unique features of the Halcyon system.Methods and materialsThe study collected and analyzed dose volume histogram (DVH) data for two groups of treatment plans implemented using the Halcyon system. The first group consisted of 19 patients who received conventional fractionated (CF) treatment with a total dose of 50 Gy in 25 fractions, while the second group comprised 9 patients who received hypofractionated (HF) treatment with a total dose of 42.56 Gy in 16 fractions. The DVH data was used to calculate various parameters, including tumor control probability (TCP), normal tissue complication probability (NTCP), and equivalent uniform dose (EUD), using radiobiological models.ResultsThe results indicated that the CF plan resulted in higher TCP but lower NTCP for the lungs compared to the HF plan. The EUD for the HF plan was approximately 49 Gy (114% of its total dose) while that for the CF plan was around 53 Gy (107% of its total dose).ConclusionsThe analysis suggests that while the CF plan is better at controlling tumors, it is not as effective as the HF plan in minimizing side effects. Additionally, it is suggested that there may be an optimal configuration for the HF plan that can provide the same or higher EUD than the CF plan.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A Comparison Between Sequential Conventional and Hypofractionated Boost Following Whole-Breast Radiotherapy: A Propensity Score-Matched Analysis
    Rajan, Jewel
    Rajeev, K. R.
    George, Preethi Sara
    Arjunan, Asha
    Balakrishnan, Priya
    Augustine, Paul
    Mathew, Beela Sarah
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [2] Dosimetric and radiobiological comparison of prostate VMAT plans optimized using the photon and progressive resolution algorithm
    Chow, James C. L.
    Jiang, Runqing
    Xu, Lu
    MEDICAL DOSIMETRY, 2020, 45 (01) : 14 - 18
  • [3] Dosimetric Comparison Between 3-Dimensional Conformal and Robotic SBRT Treatment Plans for Accelerated Partial Breast Radiotherapy
    Goggin, L. M.
    Descovich, M.
    McGuinness, C.
    Shiao, S.
    Pouliot, J.
    Park, C.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (03) : 437 - 445
  • [4] Physical and Radiobiological Dosimetric Comparison of Volumetric Arc Treatment Plans with or without Flattening Filter in Synchronous Bilateral Breast Cancer
    Patil, Deepali
    Zope, Mukesh
    Madhawi, Richa
    Raj, Shraddha
    Kishor, Kunal
    Devi, Seema
    Singh, Rajesh
    Singh, Devraj
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2024, 39 (04): : 411 - 422
  • [5] Dosimetric and radiobiological comparison for quality assurance of IMRT and VMAT plans
    Paudel, Nava Raj
    Narayanasamy, Ganesh
    Han, Eun Young
    Penagaricano, Jose
    Mavroidis, Panayiotis
    Zhang, Xin
    Pyakuryal, Anil
    Kim, Dongwook
    Liang, Xiaoying
    Morrill, Steven
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 237 - 244
  • [6] Dosimetric and radiobiological comparison of TomoTherapy and IMRT plans for prostate cancer
    Pourfarshid, Amin
    Mesbahi, Asghar
    Mohammadzadeh, Mohammad
    Molazadeh, Mikaeil
    Zeinali, Ahad
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [7] Hypofractionated versus Conventional Postmastectomy Irradiation for Breast Cancer: Comparison of Acute Skin Toxicity
    Wu, Zhiyuan
    Hou, Lili
    Li, Cheng
    Li, Xiaohua
    Li, Ying
    BREAST CANCER-TARGETS AND THERAPY, 2024, 16 : 423 - 432
  • [8] Comparison of treatment plans for hypofractionated high-dose prostate cancer radiotherapy using the Varian Halcyon and the Elekta Synergy platforms
    Tamihardja, Joerg
    Razinskas, Gary
    Exner, Florian
    Richter, Anne
    Kessler, Patrick
    Weick, Stefan
    Kraft, Johannes
    Mantel, Frederick
    Flentje, Michael
    Polat, Buelent
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 262 - 270
  • [9] Dosimetric comparison of VitalBeam® and Halcyon™ 2.0 for hypofractionated VMAT with simultaneous integrated boost treatment of early-stage left-sided breast cancer
    Ju, Eunbin
    Heo, Eun Jeong
    Park, Chun Gun
    Kim, Minseok
    Kim, Kwang Hyeon
    Shim, Jang Bo
    Park, Young Je
    Lee, Nam Kwon
    Kim, Chul Yong
    Lee, Suk
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (10): : 232 - 238
  • [10] Spontaneous Rib Fractures After Breast Cancer Treatment Based on Bone Scans: Comparison Of Conventional Versus Hypofractionated Radiotherapy
    Kim, Do Wook
    Kim, Jae Sik
    Kim, Kyubo
    Shin, Kyung Hwan
    CLINICAL BREAST CANCER, 2021, 21 (01) : E80 - E87