All-polyethylene versus metal-backed tibial components in total knee arthroplasty: a meta-analysis of randomized controlled trials

被引:5
作者
Elmhiregh, Aissam [1 ]
Abuodeh, Yousef [2 ]
Alzobi, Osama [2 ]
Zikria, Bashir [3 ]
Alkhayarin, Mohd [2 ]
Morrey, Bernard F. [4 ]
机构
[1] Almowasafat Hosp, Tripoli, Libya
[2] Hamad Med Corp, Surg Specialty Ctr, Dept Orthopaed Surg, Doha, Qatar
[3] Aspetar Orthopaed & Sports Med Hosp, Doha, Qatar
[4] Mayo Clin, Rochester, MN USA
关键词
Total knee arthroplasty; TKA; All-polyethylene; Metal-backed; RSA; Knee society score; MOBILE;
D O I
10.1007/s00590-023-03594-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectivesThe design of tibial trays for total knee arthroplasty (TKA) has been a topic of research for several decades. Although all-polyethylene trays were developed to address issues such as osteolysis and to enhance the longevity of the prosthesis, as well as knee range of motion, metal-backed designs have remained the most commonly used type of prosthesis. This meta-analysis aimed to compare the clinical, radiological, and survival outcomes of both designs.MethodsFive databases were searched from inception until October 1, 2020, for randomized controlled trials (RCTs) that compared the outcomes of all-polyethylene and metal-backed tibial components in TKA. The outcomes of interest included range of motion, knee society score, stairs climbing scores, radiostereographic analysis, survivorship and complication. This review was conducted in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Risk of bias was assessed using the Newcastle-Ottawa tool.ResultsA total of 14 RCTs with 1367 TKA were included with a mean age of - years and - years for all-polyethylene and metal-backed tibial components groups, respectively. All-polyethylene group demonstrated statistically significant differences in five-year survivorship (OR 0.27; 95% CI 0.10-0.75; p value 0.01) and stairs climbing score (OR - 2.07; 95% CI - 3.27-0.87; p value 0.0007) when compared to the metal-backed group. The metal-backed design was significantly more radiographically stable in anterior-posterior, varus-valgus, and internal-external rotations at the 2-year follow-up compared to all-polyethylene tibias (OR - 0.09; 95% CI - 0.16 to - 0.02; p value 0.02) as per the pooled radiostereographic analysis. However, ten-year survivorship (OR 0.92; 95% CI 0.53-1.60; p value 0.78), range of motion (OR - 0.57; 95% CI - 2.00-0.85, p value 0.43), knee society scores (OR 1.38; 95% CI - 0.47-3.23, p value 0.14), and complications (OR 0.83; 95% CI 0.5-1.39, p value 0.48) were comparable between both groups.ConclusionsWhile this meta-analysis suggests that all-polyethylene tibial components in total knee arthroplasty may offer advantages over metal-backed components in terms of five-year survivorship, and stairs climbing score, this finding should be considered in the context of potential confounding factors. Nonetheless, based on the results, the all-polyethylene implant should be considered a viable choice for primary knee replacement.
引用
收藏
页码:3611 / 3622
页数:12
相关论文
共 38 条
  • [1] A randomized controlled trial of fixed-versus mobile-bearing total knee arthroplasty A FOLLOW-UP AT A MEAN OF TEN YEARS
    Abdel, M. P.
    Tibbo, M. E.
    Stuart, M. J.
    Trousdale, R. T.
    Hanssen, A. D.
    Pagnano, M. W.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (07) : 925 - 929
  • [2] Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty -: Prospective, randomized radiostereometric analysis study of the AGC total knee prosthesis
    Adalberth, G
    Nilsson, KG
    Byström, S
    Kolstad, K
    Milbrink, J
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (06) : 783 - 792
  • [3] All-polyethylene versus metal-backed and stemmed tibial components in cemented total knee arthroplasty -: A prospective, randomised RSA study
    Adalberth, G
    Nilsson, KG
    Byström, S
    Kolstad, K
    Milbrink, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06): : 825 - 831
  • [4] A randomised controlled trial of the clinical effectiveness and cost-effectiveness of different knee prostheses: the Knee Arthroplasty Trial (KAT)
    不详
    [J]. HEALTH TECHNOLOGY ASSESSMENT, 2014, 18 (19) : 1 - +
  • [5] APEL DM, 1991, CLIN ORTHOP RELAT R, P243
  • [6] All-Polyethylene Compared with Metal-Backed Tibial Components in Total Knee Arthroplasty at Ten Years A Prospective, Randomized Controlled Trial
    Bettinson, Karen A.
    Pinder, Ian M.
    Moran, Chris G.
    Weir, David J.
    Lingard, Elizabeth A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07) : 1587 - 1594
  • [7] All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty
    Brihault, Jean
    Navacchia, Alessandro
    Pianigiani, Silvia
    Labey, Luc
    De Corte, Ronny
    Pascale, Valerio
    Innocenti, Bernardo
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2550 - 2559
  • [8] Busch A, 2020, ORTHOPADE, V49, P1077, DOI 10.1007/s00132-019-03830-6
  • [9] The Knee Arthroplasty Trial (KAT) Design Features, Baseline Characteristics, and Two-Year Functional Outcomes After Alternative Approaches to Knee Replacement
    Campbell, Marion
    Fiddian, Nick
    Fitzpatrick, Ray
    Grant, Adrian
    Gray, Alastair
    Morris, Richard
    Murray, David
    Rowley, David
    Johnston, Linda
    MacLennan, Graeme
    McCormack, Kirsty
    Ramsay, Craig
    Walker, Allan
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) : 134 - 141
  • [10] Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?
    Cheng, Tao
    Pan, Xiaoyun
    Liu, Tao
    Zhang, Xianlong
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (08) : 1438 - 1449