Field Pull-Out Tests of Percussion Driven Earth Anchors (PDEAs)

被引:2
作者
Asfaw, Natnael Tilahun [1 ]
Lei, Gang [1 ]
Azizian, Mehran [1 ]
Poudel, Arjan [1 ]
Hoyos, Laureano [1 ]
Yu, Xinbao [1 ]
机构
[1] Univ Texas Arlington, Dept Civil Engn, Arlington, TX 76019 USA
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 04期
关键词
percussion driven earth anchors; field pull-out test; pull-out capacity estimation method; UPLIFT; PERFORMANCE; CAPACITY; PLATES; RESISTANCE; BEHAVIOR; PILES;
D O I
10.3390/app13042132
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Percussion driven earth anchors (PDEAs) are driven into soils using an installation steel hammer rod. PDEAs are relatively easy to install and have gained wide applications recently. The Texas Department of Transportation (TxDOT) planned to use these anchors for slope stability mitigation along the Clear Fork Trinity River at Interstate Highway 20 (IH-20) in Benbrook, Texas. However, there are no straightforward design and construction guidelines for these systems. In addition, the pull-out capacity and failure mechanisms of PDEAs in clayey soils have not been thoroughly studied. In this study, three PDEAs, Duckbill model 138 II (DB-138 II), were installed and tested on the proposed west channel bank slope to acquire the ultimate pull-out capacity. The anchors were embedded to an average depth of 10 feet into the slope bank, predominantly consisting of sandy lean clay (CL) soil. The slope was graded at an average 2:1 to 2.5:1 configuration. After installation, the anchors were subjected to an upward pull-out force using a hydraulic jack system to measure their pull-out capacity. The pull-out load, displacement, and strains were continuously recorded with a load cell, a linear variable differential transformer (LVDT), and a strain gauge, respectively. Pull-out load versus displacement curves were produced and analyzed to determine the behavior of the anchors. An empirical estimation method was then chosen to estimate pull-out capacity based on undrained shear strengths obtained either from laboratory tests or in situ Texas cone penetration (TCP) data. The comparison between estimated and field-obtained pull-out capacities showed that the pull capacity estimated using TCP data resulted in reasonably good agreement with the field-obtained capacity. The field experiment results help us to understand the relationship between the calculated and actual field pull-out resistance when PDEAs are used in clayey soil slopes.
引用
收藏
页数:16
相关论文
共 39 条
  • [1] [Anonymous], 2012, D69812 ASTM, V3, P1
  • [2] [Anonymous], 2014, D85414 ASTM
  • [3] [Anonymous], 2004, D691304 ASTM
  • [4] [Anonymous], 2016, STANDARD TEST METHOD
  • [5] ASTM, 2017, STANDARD TEST METHOD, DOI [10.1520/C0109_C0109M-21, DOI 10.1520/D4318-17E01]
  • [6] Baker W.H., 1966, HIGHW RES REC, V108, P1
  • [7] Balla A., 1961, Proceedings of the 5th International Conference on Soil Mechanics and Foundation Engineering, V1, P569
  • [8] Das B.M., 1980, Soils and Foundations, V20, P77, DOI DOI 10.3208/SANDF1972.20.77
  • [9] Das B.M., 1978, Soils and Foundations, V18, P17, DOI [DOI 10.3208/SANDF1972.18.2_17, 10.3208/sandf1972.18.217]
  • [10] Geocell reinforcement for performance improvement of vertical plate anchors in sand
    Dash, Sujit Kumar
    Choudhary, Awdhesh Kumar