Deep Learning Super-Resolution Reconstruction for Fast and Motion-Robust T2-weighted Prostate MRI

被引:50
作者
Bischoff, Leon M. [1 ,2 ]
Peeters, Johannes M. [5 ]
Weinhold, Leonie [3 ]
Krausewitz, Philipp [4 ]
Ellinger, Joerg [4 ]
Katemann, Christoph [6 ]
Isaak, Alexander [1 ,2 ]
Weber, Oliver M. [6 ]
Kuetting, Daniel [1 ,2 ]
Attenberger, Ulrike
Pieper, Claus C. [1 ]
Sprinkart, Alois M. [1 ,2 ]
Luetkens, Julian A. [1 ,2 ]
机构
[1] Univ Hosp Bonn, Dept Diagnost & Intervent Radiol, Venusberg Campus 1, D-53127 Bonn, Germany
[2] Univ Hosp Bonn, Quantitat Imaging Lab Bonn QILaB, Venusberg Campus 1, D-53127 Bonn, Germany
[3] Univ Hosp Bonn, Inst Med Biometry Informat & Epidemiol, Venusberg Campus 1, D-53127 Bonn, Germany
[4] Univ Hosp Bonn, Dept Urol, Venusberg Campus 1, D-53127 Bonn, Germany
[5] Philips MR Clin Sci, Best, Netherlands
[6] Philips Market DACH, Hamburg, Germany
关键词
CANCER;
D O I
10.1148/radiol.230427
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose: To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods: In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2 (C)) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2 (NC)) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2 (DL)) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen kappa. Results: This study included 109 male participants (mean age, 68 years +/- 8 [SD]). Acquisition time of T2 (DL) was 36% and 29% lower compared with that of T2 (C) and T2 (NC) (mean duration, 164 seconds +/- 20 vs 257 seconds +/- 32 and 230 seconds +/- 28; P <.001 for both). T2 (DL) showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2 (C) and 4 [IQR, 3-4] for T2 (NC); P <.001 for both) and quantitative (mean edge rise distance, 0.75 mm +/- 0.39 vs 1.15 mm +/- 0.68 for T2 (C) and 0.98 mm +/- 0.65 for T2 (NC); P <.001 and P =.01) methods. PI-RADS score agreement between T2 (NC) and T2 (DL) was excellent (. range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion: DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings.
引用
收藏
页数:9
相关论文
共 23 条
[1]  
ACR, Prostate Imaging Reporting & Data System (PI-RADS).
[2]  
Agarwal S, 2017, Biomed Pharmacol J, V10
[3]   Deep Learning Reconstruction for Accelerated Spine MRI: Prospective Analysis of Interchangeability [J].
Almansour, Haidara ;
Herrmann, Judith ;
Gassenmaier, Sebastian ;
Afat, Saif ;
Jacoby, Johann ;
Koerzdoerfer, Gregor ;
Nickel, Dominik ;
Mostapha, Mahmoud ;
Nadar, Mariappan ;
Othman, Ahmed E. .
RADIOLOGY, 2023, 306 (03)
[4]   T2 Turbo Spin Echo With Compressed Sensing and Propeller Acquisition (Sampling k-Space by Utilizing Rotating Blades) for Fast and Motion Robust Prostate MRI Comparison With Conventional Acquisition [J].
Bischoff, Leon M. ;
Katemann, Christoph ;
Isaak, Alexander ;
Mesropyan, Narine ;
Wichtmann, Barbara ;
Kravchenko, Dmitrij ;
Endler, Christoph ;
Kuetting, Daniel ;
Pieper, Claus C. ;
Ellinger, Joerg ;
Weber, Oliver ;
Attenberger, Ulrike ;
Luetkens, Julian A. .
INVESTIGATIVE RADIOLOGY, 2023, 58 (03) :209-215
[5]   Super-resolution musculoskeletal MRI using deep learning [J].
Chaudhari, Akshay S. ;
Fang, Zhongnan ;
Kogan, Feliks ;
Wood, Jeff ;
Stevens, Kathryn J. ;
Gibbons, Eric K. ;
Lee, Jin Hyung ;
Gold, Garry E. ;
Hargreaves, Brian A. .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) :2139-2154
[6]   Parallel MR imaging [J].
Deshmane, Anagha ;
Gulani, Vikas ;
Griswold, Mark A. ;
Seiberlich, Nicole .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (01) :55-72
[7]   Image Super-Resolution Using Deep Convolutional Networks [J].
Dong, Chao ;
Loy, Chen Change ;
He, Kaiming ;
Tang, Xiaoou .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2016, 38 (02) :295-307
[8]   MRI-Targeted or Standard Biopsy in Prostate Cancer Screening [J].
Eklund, Martin ;
Jaderling, Fredrik ;
Discacciati, Andrea ;
Bergman, Martin ;
Annerstedt, Magnus ;
Aly, Markus ;
Glaessgen, Axel ;
Carlsson, Stefan ;
Groenberg, Henrik ;
Nordstroem, Tobias .
NEW ENGLAND JOURNAL OF MEDICINE, 2021, 385 (10) :908-920
[9]   Prospectively Accelerated T2-Weighted Imaging of the Prostate by Combining Compressed SENSE and Deep Learning in Patients with Histologically Proven Prostate Cancer [J].
Harder, Felix N. ;
Weiss, Kilian ;
Amiel, Thomas ;
Peeters, Johannes M. ;
Tauber, Robert ;
Ziegelmayer, Sebastian ;
Burian, Egon ;
Makowski, Marcus R. ;
Sauter, Andreas P. ;
Gschwend, Juergen E. ;
Karampinos, Dimitrios C. ;
Braren, Rickmer F. .
CANCERS, 2022, 14 (23)
[10]   Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer [J].
Hegde, John V. ;
Mulkern, Robert V. ;
Panych, Lawrence P. ;
Fennessy, Fiona M. ;
Fedorov, Andriy ;
Maier, Stephan E. ;
Tempany, Clare M. C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (05) :1035-1054