Errors in measurement of glomerular filtration rate using the slope-intercept technique and their identification

被引:0
|
作者
Oliveira, Ana [1 ,2 ]
Conway, Lauren [1 ,2 ]
Heraghty, Neil [1 ,2 ]
Peters, A. Michael [1 ,2 ,3 ]
机构
[1] Kings Coll Hosp London, Mol Imaging Ctr, Harley St Clin, London, England
[2] Kings Coll Hosp London, Dept Nucl Med, London, England
[3] Kings Coll Hosp London, Dept Nucl Med, Denmark Hill, London SE5 9RS, England
关键词
glomerular filtration rate; kidney; quality control;
D O I
10.1097/MNM.0000000000001788
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundGFR measured from plasma sampling may be expressed as slope-intercept GFR (SI-GFR) and scaled to body surface area (mGFR/BSA) or as GFR per unit extracellular fluid volume (mGFR/ECV), which is based only on half-time. Measurement errors comprise 3 categories. Pre-injection error arises from error in administered marker and is suspected when mGFR/BSA and mGFR/ECV disagree. Injection errors include 'tissued' injections. Post-injection errors include inaccurate sample timing, inaccurate pipetting, sample haemolysis and sampling through long IV lines through which marker was administered. The aim of the study was to evaluate the impact of errors on mGFR.MethodsWe compared mGFR/BSA with mGFR/ECV in 898 patients undergoing routine investigation. To investigate post-injection error, we took two further patient datasets with r values (correlation coefficient of the 3-sample fit) of 1.0 and introduced errors, in isolation, into each of the 3 recorded sample values, as follows: pipetting (volume) errors of -20%, -10%, -5%, 5%, 10% and 20%, and timing errors of -15 min, -10 min, -5 min, 5 min, 10 min and 15 min.ResultsThe correlation between mGFR/BSA and mGFR/ECV was close and independent of r. Post-injection error depended on the time of the sample in which it occurred. r correlated poorly with error magnitude for both volume and timing errors. When a 'rogue' sample is suspected its error needed to be substantial for it to be identified by single sample estimates applied to the other samples.ConclusionSI-GFR is resistant to post-injection timing and volume errors but not to pre-injection error.
引用
收藏
页码:51 / 60
页数:10
相关论文
共 50 条
  • [1] Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (12) : 1086 - 1092
  • [2] Correction of the slope-intercept method for the measurement of glomerular filtration rate
    Blake, Glen M.
    Barnfield, Mark C.
    Burniston, Maria T.
    Fleming, John S.
    Cosgriff, Philip S.
    Siddique, Musib
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (12) : 1277 - 1283
  • [3] Calculating the precision of slope-intercept glomerular filtration rate measurements
    Memmott, Matthew J.
    Lawson, Richard S.
    NUCLEAR MEDICINE COMMUNICATIONS, 2022, 43 (08) : 959 - 966
  • [4] Propagation of measurement errors in glomerular filtration rate determination: a comparison of slope-intercept, single-sample and slope-only methods
    Holness, Jennifer L.
    Fleming, John S.
    Chirehwa, Maxwell T.
    Warwick, James M.
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (04) : 333 - 342
  • [5] Correction of slope-intercept glomerular filtration rate measurement without scaling for body size
    McMeekin, Helena
    Burniston, Maria T.
    Barnfield, Mark
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (01) : 68 - 72
  • [6] Quality control of slope-intercept measurements of glomerular filtration rate using single-sample estimates
    Fleming, JS
    Persaud, L
    Zivanovic, MA
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (08) : 737 - 742
  • [7] Accuracy of next-day single-sample measurement for low glomerular filtration rate and comparison with same-day slope-intercept glomerular filtration rate
    McMeekin, Helena
    Wickham, Fred
    Fongenie, Ben
    Burniston, Maria
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (02) : 169 - 172
  • [8] An improved equation for correcting slope-intercept measurements of glomerular filtration rate for the single exponential approximation
    Fleming, John S.
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (04) : 315 - 320
  • [9] A systematic review of single-sample glomerular filtration rate measurement techniques and demonstration of equal accuracy to slope-intercept methods
    McMeekin, Helena
    Wickham, Fred
    Barnfield, Mark
    Burniston, Maria
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (07) : 743 - 755
  • [10] Comparison between slope-intercept and slope-only techniques for measuring glomerular filtration rate: Use of two independent markers and an independent arbiter
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (09) : 711 - 718