Platinum determination by membrane complexation and energy dispersive x-ray fluorescence analysis-A preliminary study

被引:1
作者
Vlamaki, Georgia P. [1 ,4 ]
Kallithrakas-Kontos, Nikolaos G. [1 ]
Queralt, Ignasi [2 ]
Hidalgo, Manuela [3 ]
机构
[1] Tech Univ Crete, Lab Analyt & Environm Chem, Univ Campus, Khania, Greece
[2] IDAEA CSIC, Inst Environm Assessment & Water Res, Barcelona, Spain
[3] Univ Girona, Fac Sci, Dept Chem, Girona, Spain
[4] Tech Univ Crete, Lab Analyt & Environm Chem, Univ Campus, GR-73100 Khania, Greece
关键词
complexing; membrane; platinum; water analysis; XRF; GROUP ELEMENTS; PALLADIUM; SEAWATER; TRACES; RHODIUM; PD;
D O I
10.1002/xrs.3368
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Platinum belongs to the technological metal group of platinum group metals, but it is finding more and more applications these days, especially in automotive catalytic converters and medicine. At the same time, the existing data on its potential toxicity both to humans and to the environment are currently rather limited, and there is also a need to increase the alternative possibilities of its chemical analysis. In this work, an attempt is made for the first time to determine platinum in aqueous samples with energy-dispersive X-ray fluorescence (EDXRF) at low concentrations. For this reason, selective complexing membranes were used that were produced in the context of the present research, after first testing many possible complexing agents. These membranes were fixed on the surface of thin films, immersed in the aqueous samples containing platinum at low concentrations, and after a certain period was collected and analyzed by EDXRF. In addition, other relevant factors such as the distribution of platinum on the membrane surface, the aging of the membrane, the effect of adding salts of various concentrations to the analyzed solution on the improvement of the achieved x-ray yields, the pH, the optimal solution volume and the necessary equilibration time were also investigated. By optimizing all relevant factors, a minimum detection limit of 4 mu g/L was achieved.
引用
收藏
页码:304 / 314
页数:11
相关论文
共 31 条
[11]   The Environmental Impact of the Platinum Group Elements (Pt, Pd, Rh) Emitted by the Automobile Catalyst Converters [J].
Kalavrouziotis, I. K. ;
Koukoulakis, P. H. .
WATER AIR AND SOIL POLLUTION, 2009, 196 (1-4) :393-402
[12]   Chromium speciation by TXRF analysis [J].
Kallithrakas-Kontos, N. ;
Koulouridakis, P. ;
Hatzistavros, V. ;
Aretaki, I. N. .
X-RAY SPECTROMETRY, 2009, 38 (02) :152-156
[13]   Recent advances in the preconcentration and determination of platinum group metals in environmental and biological samples [J].
Komendova, Renata .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 122
[14]   Seawater mercury analysis at PPB levels [J].
Koulouridakis, PE ;
Kallithrakas-Kontos, NG ;
Gekas, VC .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2006, 34 (04) :425-433
[15]   Pyridine derivative platinum complexes: Synthesis, molecular structure, DFT and initial anticancer activity studies [J].
Kutlu, Emine ;
Emen, Fatih Mehmet ;
Kismali, Gorkem ;
Kinayturk, Neslihan Kaya ;
Kilic, Derya ;
Karacolak, Ali Ihsan ;
Demirdogen, Ruken Esra .
JOURNAL OF MOLECULAR STRUCTURE, 2021, 1234 (1234)
[16]   Determination of ultra-trace Pt, Pd and Rh in seawater using an off-line pre-concentration method and inductively coupled plasma mass spectrometry [J].
Liu, Kai ;
Gao, Xuelu ;
Li, Li ;
Chen, Chen-Tung Arthur ;
Xing, Qianguo .
CHEMOSPHERE, 2018, 212 :429-437
[17]   Possible interference in the sequential voltammetric determination at trace and ultratrace concentration level of platinum group metals (PGMs) and lead - Application to environmental matrices [J].
Locatelli, Clinio .
ELECTROCHIMICA ACTA, 2006, 52 (02) :614-622
[18]   A novel flow-injection method for the determination of Pt(IV) in environmental samples based on chemiluminescence reaction of lucigenin and biosorption [J].
Malejko, Julita ;
Godlewska-Zylkiewicz, Beata ;
Kojlo, Anatol .
TALANTA, 2010, 81 (4-5) :1719-1724
[19]   SPECTROPHOTOMETRIC DETERMINATION OF TRACES OF PLATINUM IN PALLADIUM WITH DITHIZONE AFTER MATRIX PRECIPITATION AS A COMPOUND WITH AMMONIA AND IODIDE [J].
MARCZENKO, Z ;
KUS, S .
ANALYTICA CHIMICA ACTA, 1987, 196 :317-322
[20]   Determination of platinum group metal catalyst residues in active pharmaceutical ingredients by means of total reflection X-ray spectrometry [J].
Margui, Eva ;
Queralt, Ignasi ;
Hidalgo, Manuela .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 86 :50-54