The Influence of Extracerebral Tissue on Continuous Wave Near-Infrared Spectroscopy in Adults: A Systematic Review of In Vivo Studies

被引:9
作者
Eleveld, Nick [1 ]
Esquivel-Franco, Diana C. [1 ]
Drost, Gea [1 ,2 ]
Absalom, Anthony R. [3 ]
Zeebregts, Clark J. [4 ]
de Vries, Jean-Paul P. M. [4 ]
Elting, Jan Willem J. [1 ]
Maurits, Natasha M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Neurol, Postbus 30001, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Neurosurg, Postbus 30001, NL-9700 RB Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Anaesthesiol, Postbus 30001, NL-9700 RB Groningen, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Surg, Div Vasc Surg, Postbus 30001, NL-9700 RB Groningen, Netherlands
关键词
near-infrared spectroscopy; extracerebral tissue; extracranial tissue; cerebral oxygen saturation; adult population; systematic review; CEREBRAL OXYGEN-SATURATION; SKIN BLOOD-FLOW; CEREBROVASCULAR REACTIVITY; HEALTHY-VOLUNTEERS; CARDIOPULMONARY-RESUSCITATION; EXTRACRANIAL CONTAMINATION; OXIMETRY; BRAIN; ISCHEMIA; NIRS;
D O I
10.3390/jcm12082776
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Near-infrared spectroscopy (NIRS) is a non-invasive technique for measuring regional tissue haemoglobin (Hb) concentrations and oxygen saturation (rSO(2)). It may be used to monitor cerebral perfusion and oxygenation in patients at risk of cerebral ischemia or hypoxia, for example, during cardiothoracic or carotid surgery. However, extracerebral tissue (mainly scalp and skull tissue) influences NIRS measurements, and the extent of this influence is not clear. Thus, before more widespread use of NIRS as an intraoperative monitoring modality is warranted, this issue needs to be better understood. We therefore conducted a systematic review of published in vivo studies of the influence of extracerebral tissue on NIRS measurements in the adult population. Studies that used reference techniques for the perfusion of the intra- and extracerebral tissues or that selectively altered the intra- or extracerebral perfusion were included. Thirty-four articles met the inclusion criteria and were of sufficient quality. In 14 articles, Hb concentrations were compared directly with measurements from reference techniques, using correlation coefficients. When the intracerebral perfusion was altered, the correlations between Hb concentrations and intracerebral reference technique measurements ranged between |r| = 0.45-0.88. When the extracerebral perfusion was altered, correlations between Hb concentrations and extracerebral reference technique measurements ranged between |r| = 0.22-0.93. In studies without selective perfusion modification, correlations of Hb with intra- and extracerebral reference technique measurements were generally lower (|r| < 0.52). Five articles studied rSO(2). There were varying correlations of rSO(2) with both intra- and extracerebral reference technique measurements (intracerebral: |r| = 0.18-0.77, extracerebral: |r| = 0.13-0.81). Regarding study quality, details on the domains, participant selection and flow and timing were often unclear. We conclude that extracerebral tissue indeed influences NIRS measurements, although the evidence (i.e., correlation) for this influence varies considerably across the assessed studies. These results are strongly affected by the study protocols and analysis techniques used. Studies employing multiple protocols and reference techniques for both intra- and extracerebral tissues are therefore needed. To quantitatively compare NIRS with intra- and extracerebral reference techniques, we recommend applying a complete regression analysis. The current uncertainty regarding the influence of extracerebral tissue remains a hurdle in the clinical implementation of NIRS for intraoperative monitoring. The protocol was pre-registered in PROSPERO (CRD42020199053).
引用
收藏
页数:17
相关论文
共 82 条
[1]   Cerebral oximetry performance testing with a 3D-printed vascular array phantom [J].
Afshari, Ali ;
Ghassemi, Pejman ;
Lin, Jonathan ;
Halprin, Molly ;
Wang, Jianting ;
Mendoza, Gonzalo ;
Weininger, Sandy ;
Pfefer, T. Joshua .
BIOMEDICAL OPTICS EXPRESS, 2019, 10 (08) :3731-3746
[2]   Evaluation of a near-infrared spectrometer (NIRO 300) for the detection of intracranial oxygenation changes in the adult head [J].
Al-Rawi, PG ;
Smielewski, P ;
Kirkpatrick, PJ .
STROKE, 2001, 32 (11) :2492-2499
[3]   Monitoring of cerebral oxygenation with near infrared spectroscopy and tissue oxygen partial pressure during cardiopulmonary resuscitation in pigs [J].
Bein, B ;
Cavus, E ;
Stadlbauer, KH ;
Tonner, PH ;
Steinfath, M ;
Scholz, J ;
Dörges, V .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (06) :501-509
[4]   Quantification of Movement in Stroke Patients under Free Living Conditions Using Wearable Sensors: A Systematic Review [J].
Bernaldo de Quiros, Mariano ;
Douma, E. H. ;
van den Akker-scheek, Inge ;
Lamoth, Claudine J. C. ;
Maurits, Natasha M. .
SENSORS, 2022, 22 (03)
[5]   Twenty years of functional near-infrared spectroscopy: introduction for the special issue [J].
Boas, David A. ;
Elwell, Clare E. ;
Ferrari, Marco ;
Taga, Gentaro .
NEUROIMAGE, 2014, 85 :1-5
[6]   Inconsistent detection of changes in cerebral blood volume by near infrared spectroscopy in standard clinical tests [J].
Canova, D. ;
Roatta, S. ;
Bosone, D. ;
Micieli, G. .
JOURNAL OF APPLIED PHYSIOLOGY, 2011, 110 (06) :1646-1655
[7]   Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy [J].
Cho, H ;
Nemoto, EM ;
Yonas, H ;
Balzer, J ;
Sclabassi, RJ .
JOURNAL OF NEUROSURGERY, 1998, 89 (04) :533-538
[8]   Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation A Comparison of Three Cerebral Oximetty Technologies [J].
Davie, Sophie N. ;
Grocott, Hilary P. .
ANESTHESIOLOGY, 2012, 116 (04) :834-840
[9]   ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT [J].
DELPY, DT ;
COPE, M ;
VANDERZEE, P ;
ARRIDGE, S ;
WRAY, S ;
WYATT, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12) :1433-1442
[10]   Assessment of a Non-Invasive Brain Oximeter in a Sheep Model of Acute Brain Injury [J].
Dixon, Barry ;
Turner, Renee ;
Christou, Chris .
MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2019, 12 :479-487