Ocular blood flow evaluation by laser speckle flowgraphy in pediatric patients with anisometropia

被引:0
作者
Itokawa, Takashi [1 ]
Matsumoto, Tadashi [1 ]
Matsumura, Saiko [1 ]
Kawakami, Momoko [1 ]
Hori, Yuichi [1 ]
机构
[1] Toho Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
关键词
laser speckle flowgraphy; amblyopia; anisometropia; ocular blood flow; reproducibility; optic nerve disk; choroid; OPTIC-NERVE HEAD; WAVE-FORM ANALYSIS; TOMOGRAPHY ANGIOGRAPHY MEASUREMENTS; FIBER LAYER THICKNESS; 2-DIMENSIONAL MEASUREMENT; AXIAL LENGTH; AREA RATIO; CIRCULATION; AMBLYOPIA; NONCONTACT;
D O I
10.3389/fpubh.2023.1093686
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
PurposeTo determine the differences and reproducibility of blood flow among hyperopic anisometropic, fellow, and control eyes. MethodsWe retrospectively studied 38 eyes of 19 patients with hyperopic anisometropia (8.2 +/- 3.0 years of age) and 13 eyes of eight control patients (6.8 +/- 1.9 years). We measured the optic nerve head (ONH) and choroidal circulation using laser speckle flowgraphy (LSFG) and analyzed the choroidal mean blur rate (MBR-choroid), MBR-A (mean of all values in ONH), MBR-V (vessel mean), MBR-T (tissue mean), and sample size (sample), which are thought to reflect the ONH area ratio, area ratio of the blood stream (ARBS). We then assessed the coefficient of variation (COV) and intraclass correlation coefficient (ICC) and compared the differences among amblyopic, fellow, and control eyes in MBR, sample, and ARBS. ResultsThe ONH, MBR-A, MBR-T, and ARBS of amblyopic eyes were significantly higher than those of fellow eyes (P < 0.01, P < 0.05, and P < 0.05, respectively), and control eyes (MBR-A and ARBS, P < 0.05, for both comparisons). The sample-T (size of tissue component) in amblyopic eyes was significantly smaller than that in fellow and control eyes (P < 0.05). Blood flow in the choroid did not differ significantly between the eyes. The COVs of the MBR, sample, and ARBS were all <= 10%. All ICCs were >= 0.7. The COVs of pulse waveform parameter fluctuation, blowout score (BOS), blowout time (BOT), and resistivity index (RI) in the ONH and choroid were <= 10%. ConclusionThe MBR value of the LSFG in children exhibited reproducibility. Thus, this method can be used in clinical studies. The MBR values of the ONH in amblyopic eyes were significantly high. It has been suggested that measuring ONH blood flow using LSFG could detect the anisometropic amblyopic eyes.
引用
收藏
页数:8
相关论文
共 44 条
  • [1] Age- and Sex-Dependency of Laser Speckle Flowgraphy Measurements of Optic Nerve Vessel Microcirculation
    Aizawa, Naoko
    Kunikata, Hiroshi
    Nitta, Fumihiko
    Shiga, Yukihiro
    Omodaka, Kazuko
    Tsuda, Satoru
    Nakazawa, Toru
    [J]. PLOS ONE, 2016, 11 (02):
  • [2] Laser Speckle and Hydrogen Gas Clearance Measurements of Optic Nerve Circulation in Albino and Pigmented Rabbits With or Without Optic Disc Atrophy
    Aizawa, Naoko
    Nitta, Fumihiko
    Kunikata, Hiroshi
    Sugiyama, Tetsuya
    Ikeda, Tsunehiko
    Araie, Makoto
    Nakazawa, Toru
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) : 7991 - 7996
  • [3] Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma
    Aizawa, Naoko
    Yokoyama, Yu
    Chiba, Naoki
    Omodaka, Kazuko
    Yasuda, Masayuki
    Otomo, Takaaki
    Nakamura, Masahiko
    Fuse, Nobuo
    Nakazawa, Toru
    [J]. CLINICAL OPHTHALMOLOGY, 2011, 5 : 1171 - 1176
  • [4] A comparison between amblyopic and fellow eyes in unilateral amblyopia using spectral-domain optical coherence tomography
    Araki, Syunsuke
    Miki, Atsushi
    Yamashita, Tsutomu
    Goto, Katsutoshi
    Haruishi, Kazuko
    Ieki, Yoshiaki
    Kiryu, Junichi
    [J]. CLINICAL OPHTHALMOLOGY, 2014, 8 : 2199 - 2207
  • [5] Asymmetry in optic disc morphometry as measured by confocal scanning laser ophthalmoscopy in subjects with hyperopic anisometropia
    Bozkurt, Banu
    Irkec, Murat
    Arslan, Umut
    [J]. JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2008, 45 (03) : 156 - 160
  • [6] Enaida Hiroshi, 2010, Ophthalmic Surg Lasers Imaging, V41 Online, pe1, DOI 10.3928/15428877-20101124-11
  • [7] Global prevalence of amblyopia and disease burden projections through 2040: a systematic review and meta-analysis
    Fu, Zhujun
    Hong, Hao
    Su, Zhicai
    Lou, Bin
    Pan, Chen-Wei
    Liu, Hu
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (08) : 1164 - 1170
  • [8] Hashimoto Ryuya, 2017, Am J Ophthalmol Case Rep, V8, P39, DOI 10.1016/j.ajoc.2017.10.010
  • [9] Distribution of optic disc parameters measured by OCT: Findings from a population-based study of 6-year-old Australian children
    Huynh, Son C.
    Wang, Xiu Ying
    Rochtchina, Elena
    Crowston, Jonathan G.
    Mitchell, Paul
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (08) : 3276 - 3285
  • [10] Relationship between laser speckle flowgraphy and optical coherence tomography angiography measurements of ocular microcirculation
    Kiyota, Naoki
    Kunikata, Hiroshi
    Shiga, Yukihiro
    Omodaka, Kazuko
    Nakazawa, Toru
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (08) : 1633 - 1642